Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 523

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Using 915 nm Laser Excited Tm3+/Er3+/Ho3+-Doped NaYbF4 Upconversion Nanoparticles for in Vitro and Deeper in Vivo Bioimaging without Overheating Irradiation

Zhan, Qiuqiang, Qian, Jun, Liang, Huijuan, Somesfalean, Gabriel, Wang, Dan, He, Sailing, Zhang, Zhiguo, Andersson-Engels, Stefan·2011·ACS Nano

Abstract

Successful further development of superhigh-constrast upconversion (UC) bioimaging requires addressing the existing paradox: 980 nm laser light is used to excite upconversion nanoparticles (UCNPs), while 980 nm light has strong optical absorption of water and biological specimens. The overheating caused by 980 nm excitation laser light in UC bioimaging is computationally and experimentally investigated for the first time. A new promising excitation approach for better near-infrared to near-infrared (NIR-to-NIR) UC photoluminescence in vitro or in vivo imaging is proposed employing a cost-effective 915 nm laser. This novel laser excitation method provides drastically less heating of the biological specimen and larger imaging depth in the animals or tissues due to quite low water absorption. Experimentally obtained thermal-graphic maps of the mouse in response to the laser heating are investigated to demonstrate the less heating advantage of the 915 nm laser. Our tissue phantom experiments and simulations verified that the 915 nm laser is superior to the 980 nm laser for deep tissue imaging. A novel and facile strategy for surface functionalization is utilized to render UCNPs hydrophilic, stable, and cell targeting. These as-prepared UCNPs were characterized by TEM, emission spectroscopy, XRD, FTIR, and zeta potential. Specifically targeting UCNPs excited with a 915 nm laser have shown very high contrast UC bioimaging. Highly stable DSPE-mPEG-5000-encapsulated UCNPs were injected into mice to perform in vivo imaging. Imaging and spectroscopy analysis of UC photoluminescence demonstrated that a 915 nm laser can serve as a new promising excitation light for UC animal imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn200110j

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Zhan, Q., Qian, J., Liang, H., Somesfalean, G., Wang, D., He, S., Zhang, Z., & Andersson-Engels, S.
Venue
ACS Nano
Published
2011-05-02
Volume
5
Issue
5
Pages
3744-3757
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2080319759
Cited by
523
References
1
FWCI
20.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.