The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Quantum Dot–Fluorescent Protein FRET Probes for Sensing Intracellular pH
Open accessAbstract
Intracellular pH (pH(i)) plays a critical role in the physiological and pathophysiological processes of cells, and fluorescence imaging using pH-sensitive indicators provides a powerful tool to assess the pH(i) of intact cells and subcellular compartments. Here we describe a nanoparticle-based ratiometric pH sensor, comprising a bright and photostable semiconductor quantum dot (QD) and pH-sensitive fluorescent proteins (FPs), exhibiting dramatically improved sensitivity and photostability compared to BCECF, the most widely used fluorescent dye for pH imaging. We found that Förster resonance energy transfer between the QD and multiple FPs modulates the FP/QD emission ratio, exhibiting a >12-fold change between pH 6 and 8. The modularity of the probe enables customization to specific biological applications through genetic engineering of the FPs, as illustrated by the altered pH range of the probe through mutagenesis of the fluorescent protein. The QD-FP probes facilitate visualization of the acidification of endosomes in living cells following polyarginine-mediated uptake. These probes have the potential to enjoy a wide range of intracellular pH imaging applications that may not be feasible with fluorescent proteins or organic fluorophores alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Fluorescent Indicators for Intracellular pH
Han, J., & Burgess, K. (2010) · Chemical Reviews · doi:10.1021/cr900249z · Cited by 1,620
(2008) · Elsevier eBooks · doi:10.1016/b978-0-12-370501-3.x0001-x · Cited by 1,367
Panyam, J., Zhou, W., Prabha, S., Sahoo, S. K., & Labhasetwar, V. (2002) · The FASEB Journal · doi:10.1096/fj.02-0088com · Cited by 1,044
Improving the photostability of bright monomeric orange and red fluorescent proteins
Shaner, N. C., Lin, M. Z., McKeown, M. R., Steinbach, P. A., Hazelwood, K. L., Davidson, M. W., & Tsien, R. Y. (2008) · Nature Methods · doi:10.1038/nmeth.1209 · Cited by 1,009
Cellular pH regulators: potentially promising molecular targets for cancer chemotherapy
Izumi, H., Torigoe, T., Ishiguchi, H., Uramoto, H., Yoshida, Y., Tanabe, M., Ise, T., Murakami, T., Yoshida, T., Nomoto, M., et al. (2003) · Cancer Treatment Reviews · doi:10.1016/s0305-7372(03)00106-3 · Cited by 613
Quantum dot-based resonance energy transfer and its growing application in biology
Medintz, I. L., & Mattoussi, H. (2009) · Phys. Chem. Chem. Phys. · doi:10.1039/b813919a · Cited by 569
A Ratiometric CdSe/ZnS Nanocrystal pH Sensor
Snee, P. T., Somers, R. C., Nair, G., Zimmer, J. P., Bawendi, M. G., & Nocera, D. G. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0618999 · Cited by 510
Medintz, I. L., Stewart, M. H., Trammell, S. A., Susumu, K., Delehanty, J. B., Mei, B. C., Melinger, J. S., Blanco-Canosa, J. B., Dawson, P. E., & Mattoussi, H. (2010) · Nature Materials · doi:10.1038/nmat2811 · Cited by 473
Cell-Penetrating Quantum Dots Based on Multivalent and Endosome-Disrupting Surface Coatings
Duan, H., & Nie, S. (2007) · Journal of the American Chemical Society · doi:10.1021/ja068158s · Cited by 450
Bayer, N., Schober, D., Prchla, E., Murphy, R. F., Blaas, D., & Fuchs, R. (1998) · Journal of Virology · doi:10.1128/jvi.72.12.9645-9655.1998 · Cited by 329
Sensing Caspase 3 Activity with Quantum Dot−Fluorescent Protein Assemblies
Boeneman, K., Mei, B. C., Dennis, A. M., Bao, G., Deschamps, J. R., Mattoussi, H., & Medintz, I. L. (2009) · Journal of the American Chemical Society · doi:10.1021/ja809721j · Cited by 285
Self-citationSolution-Phase Single Quantum Dot Fluorescence Resonance Energy Transfer
Pons, T., Medintz, I. L., Wang, X., English, D. S., & Mattoussi, H. (2006) · Journal of the American Chemical Society · doi:10.1021/ja0657253 · Cited by 282
pH-Sensitive Photoluminescence of CdSe/ZnSe/ZnS Quantum Dots in Human Ovarian Cancer Cells
Liu, Y.-S., Sun, Y., Vernier, P. T., Liang, C.-H., Chong, S. Y. C., & Gundersen, M. A. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp0654718 · Cited by 242
Davies, T. A., Fine, R. E., Johnson, R. J., Levesque, C. A., Rathbun, W. H., Seetoo, K. F., Smith, S. J., Strohmeier, G., Volicer, L., Delva, L., et al. (1993) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1993.1853 · Cited by 234
GFP-like Proteins Stably Accumulate in Lysosomes
Katayama, H., Yamamoto, A., Mizushima, N., Yoshimori, T., & Miyawaki, A. (2008) · Cell Structure and Function · doi:10.1247/csf.07011 · Cited by 225
Suzuki, M., Husimi, Y., Komatsu, H., Suzuki, K., & Douglas, K. T. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710870e · Cited by 212
Quantum Dot−Fluorescent Protein Pairs as Novel Fluorescence Resonance Energy Transfer Probes
Dennis, A. M., & Bao, G. (2008) · Nano Letters · doi:10.1021/nl080358+ · Cited by 184
Self-citationEvaluating Nanoparticle Sensor Design for Intracellular pH Measurements
Benjaminsen, R. V., Sun, H., Henriksen, J. R., Christensen, N. M., Almdal, K., & Andresen, T. L. (2011) · ACS Nano · doi:10.1021/nn201643f · Cited by 168
Intracellular Delivery of Quantum Dot−Protein Cargos Mediated by Cell Penetrating Peptides
Medintz, I. L., Pons, T., Delehanty, J. B., Susumu, K., Brunel, F. M., Dawson, P. E., & Mattoussi, H. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800089r · Cited by 167
A quantum dot-based ratiometric pH sensor
Jin, T., Sasaki, A., Kinjo, M., & Miyazaki, J. (2010) · Chemical Communications · doi:10.1039/b921602b · Cited by 150
pH-Sensitive Ligand for Luminescent Quantum Dots
Tomasulo, M., Yıldız, İ., Kaanumalle, S. L., & Raymo, F. M. (2006) · Langmuir · doi:10.1021/la0618014 · Cited by 128
Fluorescent-Protein-Based Biosensors: Modulation of Energy Transfer as a Design Principle
Campbell, R. E. (2009) · Analytical Chemistry · doi:10.1021/ac802613w · Cited by 112
Zhang, F., Ali, Z., Amin, F., Feltz, A., Oheim, M., & Parak, W. J. (2010) · ChemPhysChem · doi:10.1002/cphc.200900849 · Cited by 106
Dennis, A. M., Sotto, D. C., Mei, B. C., Medintz, I. L., Mattoussi, H. M., & Bao, G. (2010) · Bioconjugate Chemistry · doi:10.1021/bc900500m · Cited by 101
Self-citationMeasurement of Intracellular pH
Loiselle, F. B., & Casey, J. R. (2010) · Methods in molecular biology · doi:10.1007/978-1-60761-700-6_17 · Cited by 83
Sumner, J. P., Westerberg, N. M., Stoddard, A. K., Hurst, T. K., Cramer, M., Thompson, R. B., Fierke, C. A., & Kopelman, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.04.023 · Cited by 71
Intracellular pH and Its Measurement
Kotyk, A., & Slavík, J. (2020) · CRC Press eBooks · doi:10.1201/9781003068266 · Cited by 61
Grant, R. L., & Acosta, D. (1997) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-997-0044-z · Cited by 37
Cited by
Ratiometric optical nanoprobes enable accurate molecular detection and imaging
Huang, X., Song, J., Yung, B. C., Huang, X., Xiong, Y., & Chen, X. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00612h · Cited by 820
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Förster Resonance Energy Transfer between Quantum Dot Donors and Quantum Dot Acceptors
Chou, K., & Dennis, A. (2015) · Sensors · doi:10.3390/s150613288 · Cited by 302
Self-citationMaxwell, T., Nogueira Campos, M. G., Smith, S., Doomra, M., Thwin, Z., & Santra, S. (2020) · Nanoparticles for Biomedical Applications · doi:10.1016/b978-0-12-816662-8.00015-1 · Cited by 43
Metadata
- Authors
- Dennis, A. M., Rhee, W. J., Sotto, D., Dublin, S. N., & Bao, G.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-04-02
- Volume
- 6
- Issue
- 4
- Pages
- 2917-2924
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2046584498
- Cited by
- 340
- References
- 30
- FWCI
- 16.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.