The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Ultrasensitive Immunosensor for Cancer Biomarker Proteins Using Gold Nanoparticle Film Electrodes and Multienzyme-Particle Amplification
Open accessAbstract
A densely packed gold nanoparticle platform combined with a multiple-enzyme labeled detection antibody-magnetic bead bioconjugate was used as the basis for an ultrasensitive electrochemical immunosensor to detect cancer biomarkers in serum. Sensitivity was greatly amplified by synthesizing magnetic bioconjugates particles containing 7500 horseradish peroxidase (HRP) labels along with detection antibodies (Ab2) attached to activated carboxyl groups on 1 microm diameter magnetic beads. These sensors had sensitivity of 31.5 microA mL ng(-1) and detection limit (DL) of 0.5 pg mL(-1) for prostate specific antigen (PSA) in 10 microL of undiluted serum. This represents an ultralow mass DL of 5 fg PSA, 8-fold better than a previously reported carbon nanotube (CNT) forest immunosensor featuring multiple labels on carbon nanotubes, and near or below the normal serum levels of most cancer biomarkers. Measurements of PSA in cell lysates and human serum of cancer patients gave excellent correlations with standard ELISA assays. These easily fabricated AuNP immunosensors show excellent promise for future fabrication of bioelectronic arrays.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Systems biology: a brief overview
Kitano, H. (2002) · Science · doi:10.1126/science.1069492 · Cited by 4,265
Size- and support-dependency in the catalysis of gold
Haruta, M. (1997) · Catalysis Today · doi:10.1016/s0920-5861(96)00208-8 · Cited by 4,123
Determination of Size and Concentration of Gold Nanoparticles from UV−Vis Spectra
Haiss, W., Thanh, N. T. K., Aveyard, J., & Fernig, D. G. (2007) · Analytical Chemistry · doi:10.1021/ac0702084 · Cited by 3,677
The use of nanocrystals in biological detection
Alivisatos, P. (2004) · Nature Biotechnology · doi:10.1038/nbt927 · Cited by 3,008
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Monolayer-Protected Cluster Molecules
Templeton, A. C., Wuelfing, W. P., & Murray, R. W. (2000) · Accounts of Chemical Research · doi:10.1021/ar9602664 · Cited by 2,392
Large clusters and colloids. Metals in the embryonic state
Schmid, G. (1992) · Chemical Reviews · doi:10.1021/cr00016a002 · Cited by 1,867
When Gold Is Not Noble: Nanoscale Gold Catalysts
Sanchez, A., Abbet, S., Heiz, U., Schneider, W.-D., Häkkinen, H., Barnett, R. N., & Landman, U. (1999) · The Journal of Physical Chemistry A · doi:10.1021/jp9935992 · Cited by 1,447
Lee, J., Han, M. S., & Mirkin, C. A. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700269 · Cited by 1,308
"Plugging into Enzymes": Nanowiring of Redox Enzymes by a Gold Nanoparticle
Xiao, Y., Patolsky, F., Katz, E., Hainfeld, J. F., & Willner, I. (2003) · Science · doi:10.1126/science.1080664 · Cited by 1,270
Bioassay of prostate-specific antigen (PSA) using microcantilevers
Wu, G., Datar, R. H., Hansen, K. M., Thundat, T., Cote, R. J., & Majumdar, A. (2001) · Nature Biotechnology · doi:10.1038/nbt0901-856 · Cited by 1,013
Prostate-specific antigen and prostate cancer: prediction, detection and monitoring
Lilja, H., Ulmert, D., & Vickers, A. J. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2351 · Cited by 921
A nanometre-scale electronic switch consisting of a metal cluster and redox-addressable groups
Gittins, D. I., Bethell, D., Schiffrin, D. J., & Nichols, R. J. (2000) · Nature · doi:10.1038/35040518 · Cited by 744
Weston, A. D., & Hood, L. (2004) · Journal of Proteome Research · doi:10.1021/pr0499693 · Cited by 731
Enzyme immunoassays with special reference to ELISA techniques.
Voller, A., Bartlett, A., & Bidwell, D. E. (1978) · Journal of Clinical Pathology · doi:10.1136/jcp.31.6.507 · Cited by 700
Synthesis and electrochemical applications of gold nanoparticles
Guo, S., & Wang, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.054 · Cited by 693
Carbon Nanotube Amplification Strategies for Highly Sensitive Immunodetection of Cancer Biomarkers
Yu, X., Munge, B., Patel, V., Jensen, G., Bhirde, A., Gong, J. D., Kim, S. N., Gillespie, J., Gutkind, J. S., Papadimitrakopoulos, F., et al. (2006) · Journal of the American Chemical Society · doi:10.1021/ja062117e · Cited by 686
Self-citationCarbon Nanotubes for Electronic and Electrochemical Detection of Biomolecules
Kim, S. N., Rusling, J. F., & Papadimitrakopoulos, F. (2007) · Advanced Materials · doi:10.1002/adma.200700665 · Cited by 502
Self-citationWei, H., Li, B., Li, J., Wang, E., & Dong, S. (2007) · Chemical Communications · doi:10.1039/b707642h · Cited by 472
Protein architecture : interfacing molecular assemblies and immobilization biotechnology
LVOV, Y. M., & Möhwald, H. (2000) · Marcel Dekker eBooks · Cited by 316
Biosensor developments: application to prostate-specific antigen detection
Healy, D. A., Hayes, C. J., Leonard, P., McKenna, L. G., & O’Kennedy, R. J. (2007) · Trends in biotechnology · doi:10.1016/j.tibtech.2007.01.004 · Cited by 308
Nanostructured Gold Colloid Electrodes
Shipway, A. N., Lahav, M., & Willner, I. (2000) · Advanced Materials · doi:10.1002/1521-4095(200006)12:13<993::aid-adma993>3.0.co;2-3 · Cited by 254
Ultrasensitive, label-free, and real-time immunodetection using silicon field-effect transistors
Kim, A., Ah, C. S., Yu, H. Y., Yang, J.-H., Baek, I.-B., Ahn, C.-G., Park, C. W., Jun, M. S., & Lee, S. (2007) · Applied Physics Letters · doi:10.1063/1.2779965 · Cited by 250
Interfacing biology with nanoparticles
Mandal, S., Phadtare, S., & Sastry, M. (2005) · Current Applied Physics · doi:10.1016/j.cap.2004.06.006 · Cited by 238
Biosensors and bioelectrochemistry
Murphy, L. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.02.023 · Cited by 225
Zayats, M., Katz, E., Baron, R., & Willner, I. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052841h · Cited by 210
Zhao, S., Zhang, K., Bai, Y., Yang, W., & Sun, C. (2006) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2006.01.001 · Cited by 192
Proteomic patterns: their potential for disease diagnosis
Xiao, Z., Prieto, D., Conrads, T. P., Veenstra, T. D., & Issaq, H. J. (2005) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2004.10.010 · Cited by 188
Wangoo, N., Suri, C. R., & Shekhawat, G. (2008) · Applied Physics Letters · doi:10.1063/1.2902302 · Cited by 184
Serum levels of interleukin-6 in patients with primary head and neck squamous cell carcinoma.
Riedel, F., Zaiss, I., Herzog, D., Götte, K., Naim, R., & Hörmann, K. (2005) · PubMed · Cited by 162
Zhang, Z., Chouchane, S., Magliozzo, R. S., & Rusling, J. F. (2001) · Analytical Chemistry · doi:10.1021/ac010701u · Cited by 150
Self-citationProstate specific antigen: biology, biochemistry and available commercial assays
Ward, A. M., Catto, J. W. F., & Hamdy, F. C. (2001) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563011901055 · Cited by 136
Jensen, P. S., Chi, Q., Grumsen, F. B., Abad, J. M., Horsewell, A., Schiffrin, D. J., & Ulstrup, J. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp068453z · Cited by 129
Williams, T. I., Toups, K. L., Saggese, D. A., Kalli, K. R., Cliby, W. A., & Muddiman, D. C. (2007) · Journal of Proteome Research · doi:10.1021/pr070041v · Cited by 128
Radioimmunoassay: Review of basic principles
Goldsmith, S. J. (1975) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(75)80028-6 · Cited by 123
Challenges for Biomarkers in Cancer Detection
Wagner, P. D., Verma, M., & Srivastava, S. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1318.003 · Cited by 123
Expression of the tumor-associated gene MN: a potential biomarker for human renal cell carcinoma.
McKiernan, J. M., Buttyan, R. E., Bander, N. H., et al. (1997) · PubMed · Cited by 119
Yu, X., Kim, S. N., Papadimitrakopoulos, F., & Rusling, J. F. (2005) · Molecular BioSystems · doi:10.1039/b502124c · Cited by 113
Self-citationLi, D., Yan, Y., Wieckowska, A., & Willner, I. (2007) · Chemical Communications · doi:10.1039/b704731b · Cited by 110
Nanoparticle-Enhanced Diffraction Gratings for Ultrasensitive Surface Plasmon Biosensing
Wark, A. W., Lee, H. J., Qavi, A. J., & Corn, R. M. (2007) · Analytical Chemistry · doi:10.1021/ac071062b · Cited by 90
New circulating biomarkers for prostate cancer
Bensalah, K., Lotan, Y., Karam, J. A., & Shariat, S. F. (2007) · Prostate Cancer and Prostatic Diseases · doi:10.1038/sj.pcan.4501026 · Cited by 74
Proteomics in 2005/2006: Developments, Applications and Challenges
Smith, J. C., Lambert, J., Elisma, F., & Figeys, D. (2007) · Analytical Chemistry · doi:10.1021/ac070741j · Cited by 63
Mechano-Chemical Stability of Gold Nanoparticles Coated with Alkanethiolate SAMs
Henz, B. J., Hawa, T., & Zachariah, M. R. (2008) · Langmuir · doi:10.1021/la7024473 · Cited by 38
Improved Biomarkers for Prostate Cancer: A Definite Need
Carter, H. B., & Isaacs, W. B. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh174 · Cited by 23
Evaluation of Ciba Corning ACS:180 automated immunoassay system
Móra, J., Gascón-Roche, N., Rodrı́guez-Espinosa, J., Cortés-Rius, M., & González‐Sastre, F. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.3.407 · Cited by 13
Electrochemistry of Peroxidases
Ruzgas, T. A., Lindgren, A., Gorton, L. G. O., Hecht, H., Reichelt, J., & Bilitewski, U. (2002) · doi:10.1201/9780203908907-107 · Cited by 5
(2000) · doi:10.1002/1439-7641(20000804)1:1<18::aid-cphc18>3.0.co;2-l
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Physical Principles of Nanoparticle Cellular Endocytosis
Zhang, S., Gao, H., & Bao, G. (2015) · ACS Nano · doi:10.1021/acsnano.5b03184 · Cited by 1,103
Magnetic nanoparticles in biomedical applications: A review
Materón, E. M., Miyazaki, C. M., Carr, O., Joshi, N., Picciani, P. H. S., Dalmaschio, C. J., Davis, F., & Shimizu, F. M. (2021) · Applied Surface Science Advances · doi:10.1016/j.apsadv.2021.100163 · Cited by 456
Du, D., Zou, Z., Shin, Y., Wang, J., Wu, H., Engelhard, M. H., Liu, J., Aksay, I. A., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac100036p · Cited by 448
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Metadata
- Authors
- Mani, V., Chikkaveeraiah, B. V., Patel, V., Gutkind, J. S., & Rusling, J. F.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-02-13
- Volume
- 3
- Issue
- 3
- Pages
- 585-594
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2058541035
- Cited by
- 532
- References
- 51
- FWCI
- 21.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.