CoChat

Using Mass Spectrometry to Monitor Monoclonal Immunoglobulins in Patients with a Monoclonal Gammopathy

Barnidge, David R., Dasari, Surendra, Botz, Chad M., Murray, Danelle H., Snyder, Melissa R., Katzmann, Jerry A., Dispenzieri, Angela, Murray, David L. · 2014 · Journal of Proteome Research
Cited by 167

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

A monoclonal gammopathy is defined by the detection a monoclonal immunoglobulin (M-protein). In clinical practice, the M-protein is detected by protein gel electrophoresis (PEL) and immunofixation electrophoresis (IFE). We theorized that molecular mass could be used instead of electrophoretic patterns to identify and quantify the M-protein because each light and heavy chain has a unique amino acid sequence and thus a unique molecular mass whose increased concentration could be distinguished from the normal polyclonal background. In addition, we surmised that top-down MS could be used to isotype the M-protein because each immunoglobulin has a constant region with an amino acid sequence unique to each isotype. Our method first enriches serum for immunoglobulins followed by reduction using DTT to separate light chains from heavy chains and then by microflow LC-ESI-Q-TOF MS. The multiply charged light and heavy chain ions are converted to their molecular masses, and reconstructed peak area calculations for light chains are used for quantification. Using this method, we demonstrate how the light chain portion of an M-protein can be monitored by molecular mass, and we also show that in sequential samples from a patient with multiple myeloma the light chain portion of the M-protein was detected in all samples, even those negative by PEL, IFE, and quantitative FLC. We also present top-down MS isotyping of M-protein light chains using a unique isotype-specific fragmentation pattern allowing for quantification and isotype identification in the same run. Our results show that microLC-ESI-Q-TOF MS provides superior sensitivity and specificity compared to conventional methods and shows promise as a viable method of detecting and isotyping an M-protein.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/pr400985k

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Barnidge, D. R., Dasari, S., Botz, C. M., Murray, D. H., Snyder, M. R., Katzmann, J. A., Dispenzieri, A., & Murray, D. L.
Venue
Journal of Proteome Research
Published
2014-02-11
Volume
13
Issue
3
Pages
1419-1427
ISSN
  • 1535-3893 (ISSN-L)
  • 1535-3907
OpenAlex
W2325138686
Cited by
167
References
24
FWCI
8.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.