The DOI matches its Crossref record; 60 of the 64 references it cites were found in a registry or an index.
Rehabilitation Robotics: Performance-Based Progressive Robot-Assisted Therapy
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“for example, controller stiffness can be adapted in response to the user's current performance and need, which has already been done (see Krebs et al., 2003;Marchal-Crespo & Reinkensmeyer, 2008b).”
From Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review (2013) · cites this paper as Krebs et al., 2003
Citations
Cites
Impedance Control: An Approach to Manipulation: Part I—Theory
Hogan, N. (1985) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3140702 · Cited by 3,673
Self-citationImpedance Control: An Approach to Manipulation
Hogan, N. (1984) · 1984 American Control Conference · doi:10.23919/acc.1984.4788393 · Cited by 2,929 · cited 1×
“Hogan), Impedance Control has been applied successfully in numerous robot applications including human-motor interaction ( Hogan, 1985 ).”
MethodSelf-citationNudo, R. J., Wise, B. M., SiFuentes, F., & Milliken, G. W. (1996) · Science · doi:10.1126/science.272.5269.1791 · Cited by 1,911 · cited 1×
“Experimental support for this idea derives primarily from measurements of synaptic branching and cortical thickness in rats raised in enriched and deprived environments (e.g., Diamond et al., 1987, 1976, 1985, 1966; Greer et al., 1982) and in monkeys recovering from ischemic injury (e.g., Nudo et al., 1996 ).”
BackgroundInduction of plasticity in the human motor cortex by paired associative stimulation
Stefan, K. (2000) · Brain · doi:10.1093/brain/123.3.572 · Cited by 1,481 · cited 1×
“The reverse is also true: improper timing has a negative effect (Classen et al., 1998; Stefan et al., 2000; Ridding et al., 1995).”
BackgroundRobot-aided neurorehabilitation
Krebs, H. I., Hogan, N., Aisen, M. L., & Volpe, B. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.662623 · Cited by 1,425
Self-citationSomatosensory cortical map changes following digit amputation in adult monkeys
Merzenich, M. M., Nelson, R. J., Stryker, M. P., Cynader, M. S., Schoppmann, A., & Zook, J. M. (1984) · Journal of Comparative Neurology · doi:10.1002/cne.902240408 · Cited by 1,328 · cited 1×
“Reorganization of cortical maps has been demonstrated in the motor system (Asanuma, 1991; Jacobs and Konoghue, 1991), sensory system ( Merzenich et al., 1984; Pons et al., 1988), visual system (Kaas et al., 1990), and auditory system (King and Moore, 1991).”
BackgroundLum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Neural, mechanical, and geometric factors subserving arm posture in humans
Mussa-Ivaldi, F., Hogan, N., & Bizzi, E. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-10-02732.1985 · Cited by 1,158 · cited 1×
“EMG has also been used to study muscle activities in normal subjects ( Mussa-Ivaldi et al., 1985 ) and in the disabled (Reinkensmeyer et al., 1999; Lum et al., 2000; Kearney and Mirbagheri, 2001; Mirbagheri et al., 2001; Dewald et al., 1995; Cozens, 1999).”
MethodSelf-citationRapid plasticity of human cortical movement representation induced by practice
Classen, J., Liepert, J., Wise, S. P., Hallett, M., & Cohen, L. G. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.79.2.1117 · Cited by 1,156
Reshaping the Cortical Motor Map by Unmasking Latent Intracortical Connections
Jacobs, K. M., & Donoghue, J. P. (1991) · Science · doi:10.1126/science.2000496 · Cited by 1,011 · cited 1×
“Reorganization of cortical maps has been demonstrated in the motor system (Asanuma, 1991; Jacobs and Konoghue, 1991 ), sensory system (Merzenich et al., 1984; Pons et al., 1988), visual system (Kaas et al., 1990), and auditory system (King and Moore, 1991).”
Background
Research works printed but not linked: 10
- Aizawa, H., Inase, M., Mushiake, H., Shima, K., and Tanji, J. 1994. Reorganization of supplementary motor areas after neocortical damage. Exp. Br. Res., 84:668–671.
- Diamond, M.C., Johnson, R.E., Protti, A.M., Ott, C., and Kajisa, L. 1985. Plasticity in the 904-day-old male rat cerebral cortex. Exp. Neurol, 87(2):309–317. · DOI
- Fukuda, O., Tsuji, T., and Kaneko, M. 1997. An EMG controlled manipulator using ANNs. IEEE InternationalWorkshop on Robot and Human Communication.
- Glees, P. 1980. Functional reorganization following hemispherectomy in man and after small experimental lesions in primates. In Recovery of Function: Theoretical Considerations for Brain Injury Rehabilitation, Bach-y-Rita P. (Ed.), Baltimore, University Park Press.
- Kato, I., Okazaki, E., Kikuchi, H., and Iwanami, K. 1967. Electropneumatically controlled hand prosthesis using pattern recognition of mio-electric signals. In Proc. 7th ICMBE.
- Krebs, H.I., Volpe, B.T., Palazzolo, J., Rohrer, B., Ferraro, M., Fasoli, S., Edelstein, L., and Hogan, N. 2001. Robot-aided neuro-rehabilitation in stroke: Interim results on the follow-up of 76 patients and on movement performance indices. In Integration of Assistive Technology in the Information Age, Mounir Mokhtari (Ed.), IOS Press, Assistive Technology Research Series, Amsterdam, 2001.
- Medical Research Council/Guarantors of Brain. 1986. Aids to the examination of the peripheral nervous system. London, Bailliere Tindall.
- Patton, J. and Mussa-Ivaldi, F.A. 2001. Robotic teaching by exploiting the nervous system's adaptive mechanisms. In Integration of Assistive Technology in the Information Age, Mounir Mokhtari (Ed.), IOS Press, Assistive Technology Research Series, Amsterdam, 2001.
- Triolo, R.J. and Moscowitz, G.D. 1985. A multi-channel time series myoprocessor for robust classification of limb functiona and estimation of muscle force. In IEEE Proc. 7th Annual Conf. Eng. Med. Biol. Soc..
- Williams, D.J., Krebs, H.I., Hogan, N. 2001. A Robot for wrist rehabilitation. IEEE-23rd EMBS.
Cited by
Items 101–200 of 812
Single trial prediction of self-paced reaching directions from EEG signals
Lew, E. Y. L., Chavarriaga, R., Silvoni, S., & Millán, J. D. R. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00222 · Cited by 83
“…Jose L. Pons, Consejo Superior de Investigaciones Científicas, Spain Reviewed by: Jose Luis Contreras-Vidal, University of Houston, USA Surjo R. Soekadar, University Hospital of Tübingen, Germany *Correspondence: José del R. Millán, Defitech Chair in Non-Invasive Brain-Machine Interface, Center…”
BackgroundMethodA New Ankle Robotic System Enabling Whole-Stage Compliance Rehabilitation Training
Dong, M., Fan, W., Li, J., Zhou, X., Rong, X., Kong, Y., & Zhou, Y. M. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.3022165 · Cited by 83
Human-Cooperative Control Design of a Walking Exoskeleton for Body Weight Support
Li, Z., Ren, Z., Zhao, K., Deng, C., & Feng, Y. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2900121 · Cited by 82
“In [29], a virtual tunnel in the task space was built in the controller of the upper-limb robot MITMANUS.”
MethodWisneski, K. J., & Johnson, M. J. (2007) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-4-7 · Cited by 82
Payedimarri, A. B., Ratti, M., Rescinito, R., Vanhaecht, K., & Panella, M. (2022) · Bioengineering · doi:10.3390/bioengineering9040129 · Cited by 79
The impact of robotic rehabilitation in children with acquired or congenital movement disorders.
Frascarelli, F., Masia, L., Rosa, G. D., Cappa, P., Petrarca, M., Castelli, E., & Krebs, H. I. (2009) · PubMed · Cited by 79
Self-citationAtashzar, S. F., Shahbazi, M., Tavakoli, M., & Patel, R. V. (2017) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2016.2594584 · Cited by 78
“There are some adaptive techniques proposed in the literature to tune the parameters of the PVT [13], [14] based on some sensorimotor measurements.”
MethodColombo, R., Sterpi, I., Mazzone, A., Delconte, C., & Pisano, F. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2195679 · Cited by 77
Hall, A. K., Backonja, U., Painter, I., Cakmak, M., Sung, M., Lau, T., Thompson, H. J., & Demiris, G. (2019) · Assistive Technology · doi:10.1080/10400435.2017.1396565 · Cited by 76
“Robots are also being developed for rehabilitation therapy, mental healthcare support, and for domestic use (Broadbent, Stafford, & MacDonald, 2009a; Krebs et al., 2003; Mordoch, Osterreicher, Guse, Roger, & Thompson, 2013; Rabbitt, Kazdin, & Scassellati, 2015; Smarr, Fausset, & Rogers, 2011).”
Human-adaptive control of series elastic actuators
Calanca, A., & Fiorini, P. (2014) · Robotica · doi:10.1017/s0263574714001519 · Cited by 76
“In fact it has been shown that patients should be active to enable the motor learning process [12], [9], [3], thus rehabilitative devices should not be coercive.”
BackgroundRehabilitation and Health Care Robotics
der Loos, H. F. M. V., & Reinkensmeyer, D. J. (2008) · Springer eBooks · doi:10.1007/978-3-540-30301-5_54 · Cited by 76
Generalized elasticities improve patient-cooperative control of rehabilitation robots
Vallery, H., Duschau-Wicke, A., & Riener, R. (2009) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209595 · Cited by 75
Adaptive Impedance Control Applied to Robot-Aided Neuro-Rehabilitation of the Ankle
Perez-Ibarra, J. C., Siqueira, A. A. G., Silva‐Couto, M. A., Russo, T. L., & Krebs, H. I. (2018) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2018.2885165 · Cited by 75
“Four important approaches to determine the appropriate timing and amount of robotic assistance have been previously proposed: performancebased adaptation [8], optimization of the human-robot interaction [9]–[11], online adaptation of the impedance controller pa-”
MethodSelf-citationA portable and spring-guided hand exoskeleton for exercising flexion/extension of the fingers
Jo, I., Park, Y., Lee, J., & Bae, J. (2019) · Mechanism and Machine Theory · doi:10.1016/j.mechmachtheory.2019.02.004 · Cited by 75
Robot-Assisted Arm Training in Chronic Stroke: Addition of Transition-to-Task Practice
Conroy, S. S., Wittenberg, G. F., Krebs, H. I., Zhan, M., Bever, C. T., & Whitall, J. (2019) · Neurorehabilitation and neural repair · doi:10.1177/1545968319862558 · Cited by 74
Self-citationYang, X., Shi, X., Xue, X., & Deng, Z. (2023) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2023.02.004 · Cited by 74
Stiffness and Impedance Control Using Lyapunov Theory for Robot-Aided Rehabilitation
Mehdi, H., & Boubaker, O. (2011) · International Journal of Social Robotics · doi:10.1007/s12369-011-0128-5 · Cited by 74
“It is also revealed that repetitive task-specific, goal-directed, robot-assisted therapy is effective in reducing motor impairments in the affected arm after stroke [10].”
BackgroundPanarese, A., Colombo, R., Sterpi, I., Pisano, F., & Micera, S. (2012) · Neurorehabilitation and neural repair · doi:10.1177/1545968311431966 · Cited by 73
An upper limb movement estimation from electromyography by using BP neural network
Zhang, L. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.12.020 · Cited by 73
A review on the mechanical design elements of ankle rehabilitation robot
Khalid, Y. M., Gouwanda, D., & Parasuraman, S. (2015) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411915585597 · Cited by 72
“Krebs et al.95 also mentioned that there is no ‘one-size-fits-all’ therapy.”
BackgroundReconfigurable workspace and torque capacity of a compliant ankle rehabilitation robot (CARR)
Zhang, M., Cao, J., Zhu, G., Miao, Q., Zeng, X., & Xie, S. Q. (2017) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2017.06.006 · Cited by 72
“obot-assisted rehabilitation solutions, as therapeutic adjuncts to facilitate clinical practice, have been actively researched in the past few decades [1].”
BackgroundMotor function assessment using wearable inertial sensors
Parnandi, A., Wade, E., & Matarić, M. J. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626156 · Cited by 72
Lower limb rehabilitation robotics: The current understanding and technology
Bhardwaj, S., Khan, A. A., & Muzammil, M. (2021) · Work · doi:10.3233/wor-205012 · Cited by 71
A BMI-based occupational therapy assist suit: asynchronous control by SSVEP
Sakurada, T., Kawase, T., Takano, K., Komatsu, T., & Kansaku, K. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00172 · Cited by 71
“…the wearer had sufficiently wide ROM, the calculated handpositions were along the straight line connecting the initial and end positions, as has been shown before for some rehabilitation robots using the minimum-jerk model (Krebs et al., 2003; Amirabdollahian et al., 2007; Wolbrecht et al., 2008).”
MethodKim, N., Lim, T., Song, K., Yang, S. H., & Lee, J. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b05025 · Cited by 71
Hsieh, Y., Lin, K., Wu, C., Shih, T.-Y., Li, M., & Chen, C. (2018) · Scientific Reports · doi:10.1038/s41598-018-20330-3 · Cited by 71
Cooperative modalities in robotic tele-rehabilitation using nonlinear bilateral impedance control
Sharifi, M., Behzadipour, S., Salarieh, H., & Tavakoli, M. (2017) · Control Engineering Practice · doi:10.1016/j.conengprac.2017.07.002 · Cited by 70
“Using the impedance/admittance control theory [32-34], interactive rehabilitation tasks were realized for interaction of a patient with a robot [5, 35]; such tasks cannot be performed well by pure position or force control.”
MethodKhairuddin, I. M., Sidek, S. N., Majeed, A. P. P. A., Razman, M. A. M., Puzi, A. A., & Yusof, H. M. (2021) · PeerJ Computer Science · doi:10.7717/peerj-cs.379 · Cited by 70
“This triggering signal can be either force, velocity, time thresholds, or even motion intent based on electromyography (EMG) or electroencephalography (EEG) ( Krebs et al., 2003 ; Colombo et al., 2005 ; Loureiro et al., 2009 ; Rechy-Ramirez & Hu, 2015 ; Bi, Feleke & Guan, 2019 ).”
BackgroundDesign and locomotion control of a hydraulic lower extremity exoskeleton for mobility augmentation
Kim, H., Shin, Y. J., & Kim, J. (2017) · Mechatronics · doi:10.1016/j.mechatronics.2017.06.009 · Cited by 69
Results of Clinicians Using a Therapeutic Robotic System in an Inpatient Stroke Rehabilitation Unit
Abdullah, H. A., Tarry, C., Lambert, C. L., Barreca, S. R., & Allen, B. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-50 · Cited by 68
Closed-Loop Brain–Machine–Body Interfaces for Noninvasive Rehabilitation of Movement Disorders
Broccard, F. D., Mullen, T. R., Chi, Y. M., Peterson, D., Iversen, J. R., Arnold, M., Kreutz-Delgado, K., Jung, T., Makeig, S., Howard Poizner, A., et al. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1032-6 · Cited by 67
Application of a disturbance-rejection controller for robotic-enhanced limb rehabilitation trainings
Madoński, R., Kordasz, M., & Sauer, P. (2013) · ISA Transactions · doi:10.1016/j.isatra.2013.09.022 · Cited by 67
Takebayashi, T., Takahashi, K., Okita, Y., Kubo, H., Hachisuka, K., & Domen, K. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-00986-9 · Cited by 66
“Some studies [24, 26] highlighted that providing minimal robotic assistance can facilitate improvement of UE function by reducing spasticity of the affected UE in stroke survivors.”
BackgroundResultAn articulated rehabilitation robot for upper limb physiotherapy and training
Tsai, B.-C., Wang, W.-W., Hsu, L.-C., Fu, L., & Lai, J. (2010) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2010.5649567 · Cited by 66
“This rehab-robot is designed for exoskeleton-type for upper extremities rehabilitation, and it include the redundancy design combined with selective inverse kinematics (IK) solutions, the impedance control [4-6], and the EMG-trigger modified from MIT-Manus [7].”
MethodEstimating Physical Assistance Need Using a Musculoskeletal Model
Carmichael, M. G., & Liu, D. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2244889 · Cited by 65
Motor Learning Characterizes Habilitation of Children With Hemiplegic Cerebral Palsy
Krebs, H. I., Fasoli, S. E., Dipietro, L., Fragala-Pinkham, M. A., Hughes, R. L., Stein, J. M., & Hogan, N. (2012) · Neurorehabilitation and neural repair · doi:10.1177/1545968311433427 · Cited by 65
“Youngsters moved from the center to each target (10 cm) in random order, stopped, then returned to the center, with the robot delivering performance-based training (active assist-asneeded).(13) Some children were able to perform all or part of a third block of 320 point-to-point movements during their 1-hour sessions.”
MethodSelf-citationNEUROExos: A variable impedance powered elbow exoskeleton
Lenzi, T., Vitiello, N., Rossi, S., Roccella, S., Vecchi, F., & Carrozza, M. C. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979866 · Cited by 65
Bertomeu-Motos, A., Blanco, A., Badesa, F. J., Barios, J. A., Zollo, L., & García-Aracil, N. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0348-0 · Cited by 65
“Background Robot-assisted therapies have become a new tool in poststroke upper limb treatments [1, 2].”
MethodZhang, M., McDaid, A., Veale, A. J., Peng, Y., & Xie, S. Q. (2019) · IEEE Access · doi:10.1109/access.2019.2925182 · Cited by 63
“Robot-assisted rehabilitation solutions have been actively researched in the past few decades [1]–[3].”
BackgroundFrullo, J. M., Elinger, J., Pehlivan, A. U., Fitle, K., Nedley, K., Francisco, G. E., Sergi, F., & O’Malley, M. K. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00026 · Cited by 61
“…have been proposed, each focusing on a specific aspect of robotic therapy, such as assisting movements only if they are not properly timed (Krebs et al., 2003), modulating error by perturbing movements during therapy (Patton et al., 2005), guiding joints along predetermined,…”
BackgroundReview on design and control aspects of ankle rehabilitation robots
Jamwal, P. K., Hussain, S., & Xie, S. Q. (2013) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2013.866986 · Cited by 60
“In [2], difficulty of the rehabilitation exercises is adjusted based on performance measures which combines the active power”
BackgroundMethodInfluentialTreadmill vs. overground walking: different response to physical interaction
Ochoa, J., Sternad, D., & Hogan, N. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00176.2017 · Cited by 60
“…would persist for much longer, previous studies have shown that significant improvements in motor recovery can be achieved over the course of many therapy sessions, even when progress made in one therapy session did not always carry over to the next session (Buerger et al. 2004; Krebs et al. 2003).”
ResultSelf-citationReviewing high-level control techniques on robot-assisted upper-limb rehabilitation
Miao, Q., Zhang, M., Cao, J., & Xie, S. Q. (2018) · Advanced Robotics · doi:10.1080/01691864.2018.1546617 · Cited by 60
“They are either wearable exoskeleton robots (such as the ARMin III [11] and the L-EXOS [12]), or end-effector devices (such as the MIT-MANUS [13] and the hCAAR [14]).”
BackgroundInfluentialImpedance control of ankle rehabilitation robot
Tsoi, Y. H., & Xie, S. Q. (2009) · IEEE International Conference on Robotics and Biomimetics (ROBIO) · doi:10.1109/robio.2009.4913109 · Cited by 60
“For instance, impedance control is used in the ARMin and MIT-MANUS systems, both developed for upper limb rehabilitation of stroke patients [1, 2].”
MethodA review in gait rehabilitation devices and applied control techniques
Chaparro-Cárdenas, S. L., Lozano-Guzmán, A., Ramirez-Bautista, J. A., & Zavala, A. H. (2018) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2018.1447611 · Cited by 59
“This device implements active, manual (passive), isometric [108], isokinetic [109] and isotonic [110] exercises, which can be modified by the therapist depending on the feedback received from the sensors (force/torque and position).”
MethodWearable Robotics for Upper-Limb Rehabilitation and Assistance
Varghese, R. J., Freer, D., Deligianni, F., Liu, J., & Yang, G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-811810-8.00003-8 · Cited by 59
Zhang, L., Guo, S., & Sun, Q. (2020) · Applied Sciences · doi:10.3390/app11010340 · Cited by 59
Robotics and other devices in the treatment of patients recovering from stroke
Volpe, B. T., Ferraro, M., Lynch, D., Christos, P. J., Krol, J., Trudell, C., Krebs, H. I., & Hogan, N. (2004) · Current Atherosclerosis Reports · doi:10.1007/s11883-004-0064-z · Cited by 59
Self-citationAtashzar, S. F., Polushin, I. G., & Patel, R. V. (2017) · IEEE Transactions on Robotics · doi:10.1109/tro.2016.2623336 · Cited by 57
“of impairment, body dynamics, and needs for rehabilitation [11]–[13].”
BackgroundBouteraa, Y., Abdallah, I. B., & Elmogy, A. (2020) · Industrial Robot the international journal of robotics research and application · doi:10.1108/ir-02-2020-0041 · Cited by 57
Fareh, R., Elsabe, A. Y. H., Baziyad, M. S., Kawser, T., Brahmi, B., & Rahman, M. H. (2023) · Sensors · doi:10.3390/s23115054 · Cited by 56
“The MIT-MANUS provides therapy that uses repetitive massed practice of reaching toward an endpoint.”
MethodInfluentialPortable and Reconfigurable Wrist Robot Improves Hand Function for Post-Stroke Subjects
Khor, K. X., Chin, P. J. H., Yeong, C. F., Su, E. L. M., Narayanan, A. L. T., Rahman, H. B. A., & Khan, Q. I. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2692520 · Cited by 56
“Future development may also include advanced features such as performance-based adaptation [54],”
BackgroundFriends or Foes? Socioemotional Support and Gaze Behaviors in Mixed Groups of Humans and Robots
Oliveira, R., Arriaga, P., Alves‐Oliveira, P., Correia, F., Petisca, S., & Paiva, A. (2018) · ACM/IEEE International Conference on Human-Robot Interaction (HRI) · doi:10.1145/3171221.3171272 · Cited by 56
“Advances in science and technology have already allowed, to some extent, robots to become part of our life, spanning from several different uses that include their integration in educational settings (for a review, see [48], workplaces [49] or health-care [42]).”
BackgroundXu, W., Chu, B., & Rogers, E. (2014) · Control Engineering Practice · doi:10.1016/j.conengprac.2014.05.009 · Cited by 52
Do People Trust in Robot-Assisted Surgery? Evidence from Europe
Torrent‐Sellens, J., Jiménez‐Zarco, A. I., & Saigí-Rubió, F. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182312519 · Cited by 52
“In the healthcare sphere, different types of robots are used for a variety of purposes, including the early detection or treatment of a disease [13]; assistance for people with disabilities or cognitive issues to enable them to remain independent [14,15]; assistance for patients undergoing rehabilitation therapy [16];…”
BackgroundAugmented Dynamics and Motor Exploration as Training for Stroke
Huang, F. C., & Patton, J. L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192116 · Cited by 52
“robot-assisted rehabilitation has shown benefits from assisting the patient as needed [23] and employing performance-based changes in difficulty [24], [26].”
Miao, Q., Zhang, M., Wang, C., & Li, H. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1534247 · Cited by 51
“Conventional rehabilitation programs for musculoskeletal and neurological disabilities require cooperative and intensive efforts from both therapists and patients [1, 2].”
BackgroundCommunication and Inference of Intended Movement Direction during Human–Human Physical Interaction
Mojtahedi, K., Whitsell, B., Artemiadis, P., & Santello, M. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00021 · Cited by 50
“Humans can vary the dynamics of their interaction with a robot by changing the configuration of their limbs and/or modifying limb stiffness through co-contraction of opposing muscles (Perreault et al., 2001; Krebs et al., 2003; O’Neill et al., 2013; Patel et al., 2013).”
BackgroundMethodZhou, Z., Zhou, Y., Wang, N., Gao, F., Wei, K., & Wang, Q. (2014) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.09.023 · Cited by 50
Intrinsic Constraints of Neural Origin: Assessment and Application to Rehabilitation Robotics
Campolo, D., Accoto, D., Formica, D., & Guglielmelli, E. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2019781 · Cited by 50
Admittance-Based Upper Limb Robotic Active and Active-Assistive Movements
Ochoa-Luna, C., Rahman, M. H., Saad, M., Archambault, P. S., & Ferrer, S. B. (2015) · International Journal of Advanced Robotic Systems · doi:10.5772/60784 · Cited by 49
“This paper describes the next rehabilitation step: active-assistive and active rehabilitation [14-16].”
BackgroundReinkensmeyer, D. J., Wolbrecht, E. T., & Bobrow, J. E. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353215 · Cited by 49
Towards real-time haptic assistance adaptation optimizing task performance and human effort
Passenberg, C., Groten, R., Peer, A., & BUSS, M. J. (2011) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2011.5945478 · Cited by 49
“Typical application areas can be found in training scenarios [6, 7, 8] as well as in teleoperation [1] or in direct haptic human-robot interaction tasks like microsurgery [3, 5].”
BackgroundPila, O., Duret, C., Laborne, F.-X., Graciès, J., Bayle, N., & Hutin, É. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0315-1 · Cited by 47
Development of a robotic device for post-stroke home tele-rehabilitation
Díaz, I., Catalan, J. M., Badesa, F. J., Justo, X., Lledó, L. D., Ugartemendía, A., Gil, J. J., Díez, J., & García-Aracil, N. (2018) · Advances in Mechanical Engineering · doi:10.1177/1687814017752302 · Cited by 47
Choi, Y., Gordon, J., Park, H., & Schweighofer, N. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-42 · Cited by 47
“Along these lines, a number of adaptive difficulty algorithms based on performance have been implemented on robotic systems [28,54,55].”
BackgroundMazzoleni, S., Puzzolante, L., Zollo, L., Dario, P., & Posteraro, F. (2014) · IEEE Transactions on Haptics · doi:10.1109/toh.2013.73 · Cited by 46
Duret, C., Courtial, O., Grosmaire, A.-G., & Hutin, É. (2015) · BioMed Research International · doi:10.1155/2015/482389 · Cited by 46
“, Watertown, MA, Figure 1), the commercial version of theMITManus, was used for the study [31].”
MethodA Low-Cost Soft Robotic Hand Exoskeleton for Use in Therapy of Limited Hand–Motor Function
Rudd, G., Daly, L., Jovanović, V., & Čučkov, F. (2019) · Applied Sciences · doi:10.3390/app9183751 · Cited by 46
A New Design Scheme for Intelligent Upper Limb Rehabilitation Training Robot
Zhao, Y., Liang, C., Gu, Z., Zheng, Y., & Wu, Q. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17082948 · Cited by 46
Wang, C., Peng, L., & Hou, Z. (2022) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2022.3163916 · Cited by 46
“[8] developed an impedance controller for MIT-MANUS, which is based on a virtual tunnel normal to the desired trajectory direction”
MethodA review on the application of autonomous and intelligent robotic devices in medical rehabilitation
García, A., Fuentes-Aguilar, R. Q., Salgado, I., & Chaírez, I. (2022) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-022-03692-8 · Cited by 46
Assist-as-needed path control for the PASCAL rehabilitation robot
Keller, U., Rauter, G., & Riener, R. (2013) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2013.6650475 · Cited by 46
“This kind of controller is often referred to as path controller and has been used for supporting periodic movements in task space [10], [11] and in joint space [12], [13] as well as for point-topoint movements of the arm [8], [14].”
BackgroundMethodDuret, C., Courtial, O., & Grosmaire, A.-G. (2016) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-150565 · Cited by 46
Neurorobotic and hybrid management of lower limb motor disorders: a review
Moreno, J. C., del‐Ama, A. J., Reyes-Guzmán, A. D. L., Gil-Agudo, A. M., Ceres, R., & Pons, J. L. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0821-4 · Cited by 45
“The idea of a virtual tunnel [7] to allow some range of free movement was introduced with the MIT-Manus [61] and tested with stroke patients in the lower limb exoskeleton ALEX [55].”
MethodDesign and Control of a Parallel Robot for Ankle Rehabiltation
Tsoi, Y. H., & Xie, S. Q. (2008) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/mmvip.2008.4749585 · Cited by 45
“Over the last two decades, researchers have also explored the use of robotic devices in the area of physical therapy and many devices have been developed to target various parts of the human body (Girone et al., 2001; Krebs et al., 2003; Riener et al., 2005; Takaiwa and Noritsugu, 2005; Yoon et al., 2006).”
BackgroundManual Skill Generalization Enhanced by Negative Viscosity
Huang, F. C., Patton, J. L., & Mussa-Ivaldi, F. A. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00433.2009 · Cited by 45
“Amplifying movement is especially important for individuals with motor impairment who have limited movement capabilities (Johnson et al. 2005; Kahn et al. 2006; Krebs et al. 2003).”
BackgroundDesign and control of a parallel robot for ankle rehabilitation
Tsoi, Y. H., & Xie, S. Q. (2009) · International Journal of Intelligent Systems Technologies and Applications · doi:10.1504/ijista.2010.030193 · Cited by 45
Zhou, Z., Sun, Y., Wang, N., Gao, F., Wei, K., & Wang, Q. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00016 · Cited by 45
“It can also facilitate quantitative diagnosis, provide customized therapies, and maintain medical records (Krebs et al., 2003; Stegall et al., 2013; Zhang et al., 2013).”
BackgroundDynamic Adaptive System for Robot-Assisted Motion Rehabilitation
Badesa, F. J., Morales, R., García-Aracil, N., Sabater-Navarro, J. M., Zollo, L., Papaleo, E., & Guglielmelli, E. (2014) · IEEE Systems Journal · doi:10.1109/jsyst.2014.2318594 · Cited by 44
“[3].”
Dynamic difficulty adjustment with Evolutionary Algorithm in games for rehabilitation robotics
Andrade, K. D. O., Pasqual, T. B., Caurin, G. A. P., & Crocomo, M. K. (2016) · SeGAH ... IEEE ... International Conference on Serious Games and Applications for Health/IEEE International Conference on Serious Games and Applications for Health · doi:10.1109/segah.2016.7586277 · Cited by 44
Frisoli, A., Loconsole, C., Bartalucci, R., & Bergamasco, M. (2012) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2012.09.003 · Cited by 43
A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities
Eiammanussakul, T., & Sangveraphunsiri, V. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/1927807 · Cited by 43
“Exercises may be prescribed to a stroke patient corresponding to the stage of recovery [3] and the muscle tone [2, 16], which can be graded according to the muscle contraction observability, ability to move a limb against gravity and external resistance [17].”
BackgroundAssist-as-needed ankle rehabilitation based on adaptive impedance control
Perez-Ibarra, J. C., Siqueira, A. A. G., & Krebs, H. I. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281287 · Cited by 43
“Use of impedance-controlled devices that modify their parameters according to different control objectives, as adaptation or optimization, may improve the assistance-asneeded rehabilitation systems [4].”
BackgroundSelf-citationPatient-tailored adaptive robotic system for upper-limb rehabilitation
Papaleo, E., Zollo, L., Spedaliere, L., & Guglielmelli, E. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631120 · Cited by 43
“Currently only a few attempts of robotic systems for motor therapy can be found in the literature collecting multimodal sensory signals from the patient for assessment and control, or aiming at closing the patient in the control loop [12], [13], [14], [15], [16], [17], [18], [19].”
BackgroundMethodInfluentialWang, F., Barkana, D. E., & Sarkar, N. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2058127 · Cited by 43
Control Strategies and Artificial Intelligence in Rehabilitation Robotics
Novak, D., & Riener, R. (2015) · AI Magazine · doi:10.1609/aimag.v36i4.2614 · Cited by 43
“The first implementation was EMG-triggered assistance, where the robot begins providing assistance once sufficient EMG activity is detected (Krebs et al. 2003).”
BackgroundAi, Q., Ding, B., Liu, Q., & Meng, W. (2016) · International Journal of Humanoid Robotics · doi:10.1142/s0219843616500055 · Cited by 42
Musculoskeletal Model for Path Generation and Modification of an Ankle Rehabilitation Robot
Jamwal, P. K., Hussain, S., Tsoi, Y. H., & Xie, S. Q. (2020) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2020.2989688 · Cited by 42
Design, Modeling and Control of an Ankle Rehabilitation Robot
Tsoi, Y. H., Xie, S. Q., & Graham, A. (2009) · Studies in computational intelligence · doi:10.1007/978-3-540-89933-4_18 · Cited by 42
“Both these devices are used to facilitate motor training of stroke survivors, based on the notion that physical therapy can contribute to neuro-recovery and hence improved motor functions at the affected limbs [ 17 ].”
BackgroundMethodInfluentialNajafi, M., Sharifi, M., Adams, K. D., & Tavakoli, M. (2017) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-016-0006-2 · Cited by 42
“They can also measure valuable sensory data to evaluate the users’ performance and learn their unique execution and behavioral characteristic (Krebs et al. 2003).”
BackgroundAtashzar, S. F., Shahbazi, M., & Patel, R. V. (2018) · Mechatronics · doi:10.1016/j.mechatronics.2018.03.002 · Cited by 42
Bio-Cooperative Approach for the Human-in-the-Loop Control of an End-Effector Rehabilitation Robot
di Luzio, F. S., Simonetti, D., Cordella, F., Miccinilli, S., Sterzi, S., Draicchio, F., & Zollo, L. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00067 · Cited by 41
Falzarano, V., Marini, F., Morasso, P., & Zenzeri, J. (2019) · Applied Sciences · doi:10.3390/app9132689 · Cited by 41
“Typically, the levels of assistance are triggered according to three parameters: (1) the speed of the end-effector (when the child’s arm speed exceeds a certain threshold), (2) the recorded EMG activation (when at least one of the recorded muscles overcomes a threshold) or (3) the elapsed time from the prompt stimulus…”
BackgroundToward Movement Restoration of Knee Joint Using Robust Control of Powered Orthosis
Mefoued, S., Mohammed, S., & Amirat, Y. (2013) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2012.2228194 · Cited by 41
“, impedance-based [27], [28], counterbalance-based [29], [30], EMG-based [31], [32], and performance-based adaptive assistance [33].”
A survey on the state of the art of force myography technique (FMG): analysis and assessment
Sherif, O., Bassuoni, M. M., & Mehrez, O. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03019-w · Cited by 40
Jayawardena, C., Kuo, I. H., Datta, C., Stafford, R. Q., Broadbent, E., & MacDonald, B. A. (2012) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2012.6290890 · Cited by 40
For Motion Assistance Humans Prefer to Rely on a Robot Rather Than on an Unpredictable Human
Ivanova, E., Carboni, G., Eden, J., Krüger, J., & Burdet, E. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.2987885 · Cited by 40
“In current robotic interfaces, the user’s movement is usually guided by the interface along some predefined reference trajectory, e.g. [11]–[13].”
BackgroundYun, S.-S., Kim, K., Ahn, J., & Cho, K. (2021) · Science Robotics · doi:10.1126/scirobotics.abe1243 · Cited by 40
Torque-Dependent Compliance Control in the Joint Space for Robot-Mediated Motor Therapy
Formica, D., Zollo, L., & Guglielmelli, E. (2005) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.2173009 · Cited by 39
Metadata
- Authors
- Krebs, H. I., Palazzolo, J. J., Dipietro, L., Ferraro, M., Krol, J., Rannekleiv, K., Volpe, B. T., & Hogan, N.
- Affiliations
- Cornell University (US)
- Massachusetts Institute of Technology (US)
- Scuola Superiore Sant'Anna (IT)
- Burke Rehabilitation Hospital (US)
- Venue
- Autonomous Robots
- Published
- 2003-07
- Volume
- 15
- Issue
- 1
- Pages
- 7-20
- ISSN
- 0929-5593 (ISSN-L)
- 1573-7527
- OpenAlex
- W2089421806
- Cited by
- 714
- References
- 64
- Citations by year
- 2026: 26 · 2025: 28 · 2024: 21 · 2023: 26 · 2022: 29 · 2021: 37 · 2020: 42 · 2019: 41 · 2018: 50 · 2017: 45 · 2016: 50 · 2015: 42 · 2014: 54 · 2013: 42 · 2012: 24
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Autonomous Robots (publishedVersion)
- Topics
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Social Sciences › Psychology › Social Psychology › Social Robot Interaction and HRI
- Keywords
- rehabilitation robotics, robot-assisted therapy, stroke rehabilitation, impedance control, motor impairment, task-oriented training, personalized treatment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.