Insulin pump therapy in pediatrics: a therapeutic alternative to safely lower HbA1c levels across all age groups: Pumps in pediatrics
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To examine the efficacy and safety of using continuous subcutaneous insulin infusion (CSII) therapy in a large group of patients 18 months to 18 yr from a single pediatric diabetes program. RESEARCH DESIGN AND METHODS: All patients < or = 18 yr of age starting on CSII from 1 January 1997 to 31 March 2000 at the Yale Children's Diabetes Program were included. Clinical data were collected prospectively before and during pump treatment. HbA1c was the primary efficacy outcome and rates of diabetes-related adverse events were the primary safety measures. RESULTS: One hundred and sixty-one children ranging in age from 18 months to 18 yr received CSII for an average of 32 +/- 9 months when data collection was closed on 31 October 2001, including 26 preschoolers (< 7 yr), 76 school-agers (7-11 yr) and 59 adolescents (12-18 yr). Mean HbA1c levels were 7.1% in the preschoolers, 7.8% in the school-agers and 8.1% in the adolescents prior to the start of CSII. There was a significant and consistent reduction in mean HbA1c levels after 12 months of CSII (to 6.5% in preschoolers, 7.3% in school-agers and 7.4% in adolescents, p < 0.02 vs. prepump) that was maintained at the most recent visit. Improved diabetes control was achieved with CSII without increasing daily insulin doses and in association with a decrease in the frequency of severe hypoglycemic events (p < 0.05 vs. prepump, all three age groups combined). CONCLUSIONS: CSII is an effective alternative to injection therapy in a large pediatric diabetes clinic setting. Even very young patients can utilize CSII to safely lower HbA1c levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
The Diabetes Control and Complications Trial Research Group (1995) · Diabetes · doi:10.2337/diab.44.8.968 · Cited by 1,301 · cited 1×
“Results of the DCCT indicate that this degree of improvement in metabolic control can result in a 30–40% reduction in the risk for development and progression of diabetic retinopathy (9).”
BackgroundHypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746 · cited 1×
“These findings are in contrast to DCCT results that indicate that the risk of severe hypoglycemia increases substantially as HbA1c levels are lowered (10).”
Result[Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin
Howey, D. C., Bowsher, R. R., Brunelle, R. L., & Woodworth, J. R. (1994) · Diabetes · doi:10.2337/diab.43.3.396 · Cited by 472 · cited 1×
“In CSII-treated adults, lispro insulin has been shown to lower HbA1c levels and reduce the risk of hypoglycemia compared with regular insulin (6), presumably due to the more rapid onset and shorter duration of premeal bolus doses (7).”
BackgroundBoland, E. A., Grey, M., Oesterle, A., Fredrickson, L., & Tamborlane, W. V. (1999) · Diabetes Care · doi:10.2337/diacare.22.11.1779 · Cited by 432
Self-citationLimitations of Conventional Methods of Self-Monitoring of Blood Glucose
Boland, E., Monsod, T., Delucia, M., Brandt, C. A., Fernando, S., & Tamborlane, W. V. (2001) · Diabetes Care · doi:10.2337/diacare.24.11.1858 · Cited by 423 · cited 1×
“Preliminary results of studies with continuous glucose monitoring systems have shown that conventional SMBG often misses marked postprandial hyperglycemia and asymptomatic nocturnal hypoglycemia in young people with type 1 diabetes (16, 17).”
Self-citationTamborlane, W. V., Sherwin, R. S., Genel, M., & Felig, P. (1979) · New England Journal of Medicine · doi:10.1056/nejm197903153001101 · Cited by 411 · cited 1×
“Continuous subcutaneous insulin infusion (CSII) therapy was introduced more than 20 yr ago as a means to more closely simulate normal plasma insulin profiles than could be achieved by conventional injection regimens (1).”
BackgroundSelf-citationDavis, E. A., Keating, B., Byrne, G. C., Russell, M., & Jones, T. W. (1997) · Diabetes Care · doi:10.2337/diacare.20.1.22 · Cited by 273 · cited 1×
“With injection therapy, the risk of severe hypoglycemia is greatest in infants and toddlers with low HbA1c levels (12).”
BackgroundInsulin Lispro in CSII: Results of a Double-Blind Crossover Study
Zinman, B., Tildesley, H., Chiasson, J.-L., Tsui, E., & Strack, T. (1997) · Diabetes · doi:10.2337/diab.46.3.440 · Cited by 258 · cited 1×
“In CSII-treated adults, lispro insulin has been shown to lower HbA1c levels and reduce the risk of hypoglycemia compared with regular insulin (6), presumably due to the more rapid onset and shorter duration of premeal bolus doses (7).”
Background
Cited by
Care of Children and Adolescents With Type 1 Diabetes
Silverstein, J., Klingensmith, G., Copeland, K., Plotnick, L., Kaufman, F., Laffel, L., Deeb, L., Grey, M., Anderson, B., Holzmeister, L. A., et al. (2005) · Diabetes Care · doi:10.2337/diacare.28.1.186 · Cited by 1,312
“Pumps Pump use is increasing rapidly in the pediatric population (66).”
Doyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1554 · Cited by 373
Self-citationCummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
Use of Insulin Pump Therapy in the Pediatric Age-Group
Phillip, M., Battelino, T., Rodriguez, H., Danne, T., Kaufman, F., & participants, F. T. C. F. (2007) · Diabetes Care · doi:10.2337/dc07-9922 · Cited by 316
Clinical and cost-effectiveness of continuous subcutaneous insulin infusion for diabetes
Colquitt, J., Green, C., Sidhu, M., Hartwell, D., & Waugh, N. (2004) · Health Technology Assessment · doi:10.3310/hta8430 · Cited by 249
Chronobiology in the endocrine system
Haus, E. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.01.001 · Cited by 225
“Together with the continuous or intermittentmonitoring of the response of individual patients, this approach may achieve close to optimal metabolic control, decrease early and late complications, and improve the quality of life of insulin-dependent patients [415–420].”
BackgroundDanne, T., Phillip, M., Buckingham, B. A., Jarosz-Chobot, P., Saboo, B., Urakami, T., Battelino, T., Hanas, R., & Codner, E. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12718 · Cited by 225
“Rates of hypoglycemia did not differ significantly between the two treatment groups; however, hyperglycemia with ketosis was significantly reduced in those treated with degludec, potentially offering a particular benefit for patients prone to DKA.85”
BackgroundInfluentialPańkowska, E., Błazik, M., Dziechciarz, P., Szypowska, A., & Szajewska, H. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00440.x · Cited by 209
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Weinzimer, S. A., Ahern, J. H., Doyle, E. A., Vincent, M. R., Dziura, J., Steffen, A. T., & Tamborlane, W. V. (2004) · Pediatrics · doi:10.1542/peds.2004-0092 · Cited by 166
“Race/ethnicity, n (%) White 61 (89) Black 3 (5) Hispanic 1 (4) Maternal employment status, home/away/unknown 26/38/1”
Self-citationISPAD Clinical Practice Consensus Guidelines 2022: Diabetes technologies: Insulin delivery
Sherr, J. L., Schoelwer, M., Dos Santos, T. J., Reddy, L., Biester, T., Galderisi, A., van Dyk, J. C., Hilliard, M. E., Berget, C., & DiMeglio, L. A. (2022) · Pediatric Diabetes · doi:10.1111/pedi.13421 · Cited by 152
Olinder, A. L., Kernell, A., & Smide, B. (2009) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00462.x · Cited by 129
Evaluation of Pump Discontinuation and Associated Factors in the T1D Exchange Clinic Registry
Wong, J. C., Boyle, C., DiMeglio, L. A., Mastrandrea, L. D., Abel, K.-L., Cengiz, E., Cemeroglu, P. A., Aleppo, G., Largay, J. F., Foster, N. C., et al. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816663963 · Cited by 69
Opipari-Arrigan, L., Fredericks, E. M., Burkhart, N., Dale, L., Hodge, M., & Foster, C. (2007) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00283.x · Cited by 64
Berghaeuser, M., Kapellen, T., Heidtmann, B., Haberland, H., Klinkert, C., Holl, R., & for the DPV-Science-Initiative and the German working group for insulin pump treatment in paediatric patients (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00416.x · Cited by 58
Sherr, J. L., Palau Collazo, M., Cengiz, E., Michaud, C., Carria, L., Steffen, A. T., Weyman, K., Zgorski, M., Tichy, E., Tamborlane, W. V., et al. (2014) · Diabetes Care · doi:10.2337/dc13-1608 · Cited by 35
Self-citation
Metadata
- Authors
- Ahern, J. A. H., Boland, E. A., Doane, R., Ahern, J. J., Rose, P., Vincent, M., & Tamborlane, W. V.
- Venue
- Pediatric Diabetes
- Publisher
- Hindawi Limited
- Published
- 2002-03
- Volume
- 3
- Issue
- 1
- Pages
- 10-15
- ISSN
- 1399-543X (ISSN-L)
- OpenAlex
- W2122025124
- Cited by
- 174
- References
- 17
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.