The DOI matches its Crossref record.
[Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin
Abstract
[Lys(B28, Pro(B29)]-human insulin (LYSPRO) is an insulin analogue in which the natural amino acid sequence of the B-chain at positions 28 and 29 is inverted. These changes result in an insulin molecule with a greatly reduced capacity for self-association in solution. These clinical studies were designed to compare LYSPRO with human Regular insulin after subcutaneous injection in humans. We wanted to evaluate the effect of adding zinc to LYSPRO on its pharmacokinetics and pharmacodynamics. In addition, we compared the pharmacokinetics and pharmacodynamics of LYSPRO and human Regular insulin after subcutaneous injection to those of human Regular insulin given intravenously. Thus, we compared four treatments: solutions of zinc-free LYSPRO given subcutaneously (A), zinc-containing LYSPRO given subcutaneously (B), human Regular insulin given subcutaneously (C), and human Regular insulin given intravenously (D). We gave a 10-U dose of each treatment to 10 healthy (nondiabetic) men during glucose clamps. Serum insulin concentrations peaked more than two times higher (maximum serum insulin level [Cmax], 698 vs. 308 pM, A vs. C) and in < half the time (time to Cmax [Tmax], 42 vs. 101 min, A vs. C) after subcutaneous injection of zinc-free LYSPRO. At the same time, the glucose infusion rate peaked in about half the time (time to maximum glucose infusion rate [TRmax], 99 vs. 179 min, A vs. C) and was slightly but not significantly higher (maximum glucose infusion rate [Rmax], 3.1 vs. 2.2 mmol/min, A vs. C) than that of human Regular insulin. Although the addition of zinc retarded the absorption of LYSPRO slightly (Cmax, 550 vs. 698 pM, B vs. A), zinc-containing LYSPRO retained its distinct profile (Tmax 53 vs. 42 min, B vs. A). LYSPRO displays faster pharmacodynamic action than human Regular insulin when injected subcutaneously
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Lepore, M., Pampanelli, S., Fanelli, C., Porcellati, F., Bartocci, L., Di Vincenzo, A., Cordoni, C., Costa, E., Brunetti, P., & Bolli, G. B. (2000) · Diabetes · doi:10.2337/diabetes.49.12.2142 · Cited by 818
Hirsch, I. B. (2005) · New England Journal of Medicine · doi:10.1056/nejmra040832 · Cited by 667
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Owens, D. R., Zinman, B., & Bolli, G. B. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05842-1 · Cited by 373
Metadata
- Authors
- Howey, D. C., Bowsher, R. R., Brunelle, R. L., & Woodworth, J. R.
- Venue
- Diabetes
- Publisher
- American Diabetes Association
- Published
- 1994-03-01
- Volume
- 43
- Issue
- 3
- Pages
- 396-402
- ISSN
- 0012-1797 (ISSN-L)
- 1939-327X
- OpenAlex
- W2081528927
- Cited by
- 472
- References
- 0
- FWCI
- 13.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: [Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin. https://app.cochat.ai/papers/10.2337/diab.43.3.396
- The paper
- Howey, D. C., Bowsher, R. R., Brunelle, R. L., & Woodworth, J. R. (1994). [Lys(B28), Pro(B29)]-Human Insulin: A Rapidly Absorbed Analogue of Human Insulin. Diabetes. https://doi.org/10.2337/diab.43.3.396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.