The DOI matches its Crossref record.
A histomorphometric evaluation of screw‐shaped implants each prepared with two surface roughnesses
Abstract
Four different surface modifications were designed. Forty screw‐shaped implants were divided into 4 groups, 10 screws in each. Every screw was prepared with 2 different surface topographies. The surface topography was measured with a confocal laser scanning profilometer and the surface roughness was characterized using 1 height, 1 spatial and 1 hybrid descriptive parameter. After 12 weeks in rabbit bone all screws were histomorphometrically evaluated. Blasted surfaces demonstrated more bone in contact to implant surface compared with turned surfaces. Most bone in close contact to implant surface was found for a surface blasted with 75 pm sized particles, numerically characterized with an average height deviation (S,) of 1.4 pm, an average wavelength (S dr) of 11.6 pm and a developed surface area 1 ratio (S dr) of 1.5.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Self-citationEngineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611
Metadata
- Authors
- Wennerberg, A., Hallgren, C., Johansson, C., & Danelli, S.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 1998-02
- Volume
- 9
- Issue
- 1
- Pages
- 11-19
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1982307362
- Cited by
- 339
- References
- 0
- FWCI
- 14.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A histomorphometric evaluation of screw‐shaped implants each prepared with two surface roughnesses. https://app.cochat.ai/papers/10.1034/j.1600-0501.1998.090102.x
- The paper
- Wennerberg, A., Hallgren, C., Johansson, C., & Danelli, S. (1998). A histomorphometric evaluation of screw‐shaped implants each prepared with two surface roughnesses. Clinical Oral Implants Research. https://doi.org/10.1034/j.1600-0501.1998.090102.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.