Abstract
Four different surface modifications were designed. Forty screw‐shaped implants were divided into 4 groups, 10 screws in each. Every screw was prepared with 2 different surface topographies. The surface topography was measured with a confocal laser scanning profilometer and the surface roughness was characterized using 1 height, 1 spatial and 1 hybrid descriptive parameter. After 12 weeks in rabbit bone all screws were histomorphometrically evaluated. Blasted surfaces demonstrated more bone in contact to implant surface compared with turned surfaces. Most bone in close contact to implant surface was found for a surface blasted with 75 pm sized particles, numerically characterized with an average height deviation (S,) of 1.4 pm, an average wavelength (S dr) of 11.6 pm and a developed surface area 1 ratio (S dr) of 1.5.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ti based biomaterials, the ultimate choice for orthopaedic implants – A review
Geetha, M., Singh, A. K., Asokamani, R., & Gogia, A. K. (2009) · Progress in Materials Science · doi:10.1016/j.pmatsci.2008.06.004 · Cited by 5,416
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
“This range of roughness maximizes the interlocking between mineralized bone and the surface of the implant [10,13].”
BackgroundEffects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Self-citationEngineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A., Ghazali, M. J., Razali, M., & Otsuka, Y. (2015) · BioMed Research International · doi:10.1155/2015/791725 · Cited by 611
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Biomedical applications of nanotechnology
Ramos, A. P., Cruz, M. A. E., Tovani, C. B., & Ciancaglini, P. (2017) · Biophysical Reviews · doi:10.1007/s12551-016-0246-2 · Cited by 413
A role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
Surface treatments and roughness properties of Ti-based biomaterials
Bagno, A., & Di Bello, C. (2004) · Journal of Materials Science: Materials in Medicine · doi:10.1023/b:jmsm.0000042679.28493.7f · Cited by 282
MacDonald, D. E., Rapuano, B. E., Deo, N., Stranick, M., Somasundaran, P., & Boskey, A. L. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.029 · Cited by 247
Mustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120513.x · Cited by 245
Self-citationRasouli, R., Barhoum, A., & Uludag, H. (2018) · Biomaterials Science · doi:10.1039/c8bm00021b · Cited by 242
Stich, T., Alagboso, F., Křenek, T., Kovářík, T., Alt, V., & Docheva, D. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10239 · Cited by 206
“leading to a broader territory for cell adhesion, bone-implant-contact and thus better biomechanical integrity after the bone-implantinterface is filled with new bone matrix.(12,45) Furthermore, surface roughness modifications can also lead to a surface chemistry favorable”
BackgroundIvanoff, C., Widmark, G., Hallgren, C., Sennerby, L., & Wennerberg, A. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.012002128.x · Cited by 195
Self-citationMetals for bone implants: safety, design, and efficacy
Shayesteh Moghaddam, N., Taheri Andani, M., Amerinatanzi, A., Haberland, C., Huff, S., Miller, M., Elahinia, M., & Dean, D. (2016) · Biomanufacturing Reviews · doi:10.1007/s40898-016-0001-2 · Cited by 184
Comparative analysis of collagen membranes for the treatment of implant dehiscence defects
Oh, T., Meraw, S. J., Lee, E., Giannobile, W. V., & Wang, H. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.140111.x · Cited by 166
“It has been demonstrated that the level of new BIC is significantly influenced by implant surface roughness, being greater BIC in surfaceroughened implants compared to machined titanium surfaces (Buser et al. 1991; Stentz et al. 1997; Buser et al. 1998; Wennerberg et al. 1998; Cochran 1999).”
BackgroundThe removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching
Cho, S. (2003) · Biomaterials · doi:10.1016/s0142-9612(03)00218-7 · Cited by 161
Metadata
- Authors
- Wennerberg, A., Hallgren, C., Johansson, C., & Danelli, S.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 1998-02
- Volume
- 9
- Issue
- 1
- Pages
- 11-19
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W1982307362
- Cited by
- 339
- References
- 0
- FWCI
- 14.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.