The DOI matches its Crossref record.
In vivo optical coherence tomography imaging of human skin: norm and pathology
Abstract
Background/aims: Since the majority of skin diseases are known to be accompanied by structural alterations, research efforts are focused on the development of various novel diagnostic techniques capable of providing in vivo information on the skin structure. An essential parameter here is spatial resolution. In this paper we demonstrate the capabilities of optical coherence tomography (OCT) in detecting in vivo specific features of thin and thick skin. A particular focus is made on the identification of OCT patterns typical of certain pathological processes in skin, by performing parallel histological and tomographical studies. Methods: To obtain images of the skin, we used a compact fiber OCT system developed at the Institute of Applied Physics of the Russian Academy of Sciences. A low coherence source (superluminescent diode) operated at a wavelength of 1280 nm; the output power was 0.5–2 mW. This power is low enough to conform to the ANSI safety standards for light exposure. The in‐depth resolution limited by the spectral bandwidth (40–50 nm) of the probing light was ∼20 μm. The lateral resolution determined by the probe light focusing ranged from 15 to 30 μm. In this series of experiments the maximum depth of imaging did not extend beyond 1.5 mm. Obtaining images of skin regions 2–6 mm long took 2–4 s. OCT capabilities for imaging normal skin of different localization and some skin diseases were studied in 12 healthy volunteers and 24 patients. Results: OCT imaging of the skin can detect in vivo such general pathological reactions of the human body as active inflammation and necrosis. OCT is useful for in vivo diagnosis of some specific processes in the skin, including hyperkeratosis, parakeratosis and formation of intradermal cavities. OCT imaging is noninvasive and therefore allows frequent multifocal examination of skin without any adverse effects. OCT can perform monitoring of disease progress and recovery in the course of therapy. Morphometric studies, measurements of the depth and extension of skin pathology within the human body can be easily performed by OCT. Conclusions: OCT allows imaging of subsurface soft tissues with the spatial resolution of 15–20 μm, a resolution one order of magnitude higher than that provided by other clinically available noninvasive diagnostic techniques. An imaging depth of up to 1.5–2 mm, given by current OCT technology, is sufficient to examine the skin. Real time OCT imaging can provide information not only on the structure, but also on some specific features in the functional state, of tissues. OCT imaging is a noninvasive technique, i.e., OCT does not cause trauma and has no side effects since it utilizes radiation in the near infrared wavelength range at a power as low as 1 mW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257
Using optical coherence tomography to evaluate skin sun damage and precancer
Korde, V. R., Bonnema, G. T., Xu, W., Krishnamurthy, C., Ranger‐Moore, J., Saboda, K., Slayton, L. D., Salasche, S. J., Warneke, J. A., Alberts, D. S., et al. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20573 · Cited by 145
Metadata
- Authors
- Gladkova, N. D., Petrova, G. A., Nikulin, N. K., Radenska‐Lopovok, S. G., Snopova, L. B., Chumakov, Y. P., Nasonova, V. A., Gelikonov, V. M., Gelikonov, G. V., Kuranov, R. V., Sergeev, A. M., & Feldchtein, F. I.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2000-02
- Volume
- 6
- Issue
- 1
- Pages
- 6-16
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2121572228
- Cited by
- 185
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo optical coherence tomography imaging of human skin: norm and pathology. https://app.cochat.ai/papers/10.1034/j.1600-0846.2000.006001006.x
- The paper
- Gladkova, N. D., Petrova, G. A., Nikulin, N. K., Radenska‐Lopovok, S. G., Snopova, L. B., Chumakov, Y. P., Nasonova, V. A., Gelikonov, V. M., Gelikonov, G. V., Kuranov, R. V., Sergeev, A. M., & Feldchtein, F. I. (2000). In vivo optical coherence tomography imaging of human skin: norm and pathology. Skin Research and Technology. https://doi.org/10.1034/j.1600-0846.2000.006001006.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.