In vivo optical coherence tomography imaging of human skin: norm and pathology
The DOI matches its Crossref record.
Abstract
Background/aims: Since the majority of skin diseases are known to be accompanied by structural alterations, research efforts are focused on the development of various novel diagnostic techniques capable of providing in vivo information on the skin structure. An essential parameter here is spatial resolution. In this paper we demonstrate the capabilities of optical coherence tomography (OCT) in detecting in vivo specific features of thin and thick skin. A particular focus is made on the identification of OCT patterns typical of certain pathological processes in skin, by performing parallel histological and tomographical studies. Methods: To obtain images of the skin, we used a compact fiber OCT system developed at the Institute of Applied Physics of the Russian Academy of Sciences. A low coherence source (superluminescent diode) operated at a wavelength of 1280 nm; the output power was 0.5–2 mW. This power is low enough to conform to the ANSI safety standards for light exposure. The in‐depth resolution limited by the spectral bandwidth (40–50 nm) of the probing light was ∼20 μm. The lateral resolution determined by the probe light focusing ranged from 15 to 30 μm. In this series of experiments the maximum depth of imaging did not extend beyond 1.5 mm. Obtaining images of skin regions 2–6 mm long took 2–4 s. OCT capabilities for imaging normal skin of different localization and some skin diseases were studied in 12 healthy volunteers and 24 patients. Results: OCT imaging of the skin can detect in vivo such general pathological reactions of the human body as active inflammation and necrosis. OCT is useful for in vivo diagnosis of some specific processes in the skin, including hyperkeratosis, parakeratosis and formation of intradermal cavities. OCT imaging is noninvasive and therefore allows frequent multifocal examination of skin without any adverse effects. OCT can perform monitoring of disease progress and recovery in the course of therapy. Morphometric studies, measurements of the depth and extension of skin pathology within the human body can be easily performed by OCT. Conclusions: OCT allows imaging of subsurface soft tissues with the spatial resolution of 15–20 μm, a resolution one order of magnitude higher than that provided by other clinically available noninvasive diagnostic techniques. An imaging depth of up to 1.5–2 mm, given by current OCT technology, is sufficient to examine the skin. Real time OCT imaging can provide information not only on the structure, but also on some specific features in the functional state, of tissues. OCT imaging is a noninvasive technique, i.e., OCT does not cause trauma and has no side effects since it utilizes radiation in the near infrared wavelength range at a power as low as 1 mW.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Applications of optical coherence tomography in dermatology
GAMBICHLER, T., MOUSSA, G., SAND, M., SAND, D., ALTMEYER, P., & HOFFMANN, K. (2005) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2005.07.006 · Cited by 283
Advances in Optical Coherence Tomography Imaging for Dermatology
Pierce, M. C., Strasswimmer, J., Hyle Park, B., Cense, B., & de Boer, J. F. (2004) · Journal of Investigative Dermatology · doi:10.1111/j.0022-202x.2004.23404.x · Cited by 257
Fang, L., Wang, C., Li, S., Rabbani, H., Chen, X., & Liu, Z. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2898414 · Cited by 243
“Optical coherence tomography (OCT) allows in vivo 3D cross sectional imaging of human tissue at micrometer resolutions [6]–[8], which has been widely employed in diverse medical applications [9]–[11], especially for diagnostic ophthalmology.”
BackgroundOptical coherence tomography in dermatology: technical and clinical aspects
Gambichler, T., Jaedicke, V., & Terras, S. (2011) · Archives of Dermatological Research · doi:10.1007/s00403-011-1152-x · Cited by 240
Neerken, S., Lucassen, G. W., Bisschop, M. A., Lenderink, E., & Nuijs, T. (. M. ). (2004) · Journal of Biomedical Optics · doi:10.1117/1.1645795 · Cited by 216
MOGENSEN, M., JOERGENSEN, T. M., NÜRNBERG, B. M., MORSY, H. A., THOMSEN, J. B., THRANE, L., & JEMEC, G. B. E. (2009) · Dermatologic Surgery · doi:10.1111/j.1524-4725.2009.01164.x · Cited by 205
“OCT is a noninvasive optical imaging technology that can provide cross-sectional tomographic images of tissue in situ and in real-time with high axial resolution.(4,8,18) The OCT system used was developed at the Technical University of Denmark.”
MethodOCT imaging of skin cancer and other dermatological diseases
Mogensen, M., Thrane, L., Jørgensen, T. M., Andersen, P. E., & Jemec, G. B. E. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200910020 · Cited by 201
Morphology and Epidermal Thickness of Normal Skin Imaged by Optical Coherence Tomography
Mogensen, M., Morsy, H. A., Thrane, L., & Jemec, G. B. E. (2008) · Dermatology · doi:10.1159/000118508 · Cited by 183
Review of optical coherence tomography in oncology
Wang, J., Xu, Y., & Boppart, S. A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121711 · Cited by 172
3D bioprinting of skin tissue: From pre-processing to final product evaluation
Yan, W.-C., Davoodi, P., Vijayavenkataraman, S., Tian, Y., Ng, W. C., Fuh, J. Y. H., Robinson, K. S., & Wang, C.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.016 · Cited by 171
Optical coherence tomography in contact dermatitis and psoriasis
Welzel, J., Bruhns, M., & Wolff, H. H. (2003) · Archives of Dermatological Research · doi:10.1007/s00403-003-0390-y · Cited by 164
The mechanical behavior of skin: Structures and models for the finite element analysis
Benítez, J. M., & Montáns, F. J. (2017) · Computers & Structures · doi:10.1016/j.compstruc.2017.05.003 · Cited by 162
Using optical coherence tomography to evaluate skin sun damage and precancer
Korde, V. R., Bonnema, G. T., Xu, W., Krishnamurthy, C., Ranger‐Moore, J., Saboda, K., Slayton, L. D., Salasche, S. J., Warneke, J. A., Alberts, D. S., et al. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20573 · Cited by 145
“OCT has also identified specific conditions of the skin, such as hyperkeratosis, parakeratosis, and formation of intradermal cavities [11].”
BackgroundBarton, J. K., Gossage, K. W., Xu, W., Ranger-Moore, J. R., Saboda, K., Brooks, C. A., Duckett, L. D., Salasche, S. J., Warneke, J. A., & Alberts, D. S. (2003) · Technology in Cancer Research & Treatment · doi:10.1177/153303460300200605 · Cited by 85
Metadata
- Authors
- Gladkova, N. D., Petrova, G. A., Nikulin, N. K., Radenska‐Lopovok, S. G., Snopova, L. B., Chumakov, Y. P., Nasonova, V. A., Gelikonov, V. M., Gelikonov, G. V., Kuranov, R. V., Sergeev, A. M., & Feldchtein, F. I.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2000-02
- Volume
- 6
- Issue
- 1
- Pages
- 6-16
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W2121572228
- Cited by
- 185
- References
- 0
- FWCI
- 4.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.