The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Assessment of Optical Coherence Tomography Imaging in the Diagnosis of Non-Melanoma Skin Cancer and Benign Lesions Versus Normal Skin: Observer-Blinded Evaluation by Dermatologists and Pathologists
Abstract
BACKGROUND: Optical coherence tomography (OCT) is an optical imaging technique that may be useful in diagnosis of non-melanoma skin cancer (NMSC). OBJECTIVES: To describe OCT features in NMSC such as actinic keratosis (AK) and basal cell carcinoma (BCC) and in benign lesions and to assess the diagnostic accuracy of OCT in differentiating NMSC from benign lesions and normal skin. METHODS AND MATERIALS: OCT and polarization-sensitive (PS) OCT from 104 patients were studied. Observer-blinded evaluation of OCT images from 64 BCCs, 1 baso-squamous carcinoma, 39 AKs, two malignant melanomas, nine benign lesions, and 105 OCT images from perilesional skin was performed; 50 OCT images of NMSC and 50 PS-OCT images of normal skin were evaluated twice. RESULTS: Sensitivity was 79% to 94% and specificity 85% to 96% in differentiating normal skin from lesions. Important features were absence of well-defined layering in OCT and PS-OCT images and dark lobules in BCC. Discrimination of AK from BCC had an error rate of 50% to 52%. CONCLUSION: OCT features in NMSC are identified, but AK and BCC cannot be differentiated. OCT diagnosis is less accurate than clinical diagnosis, but high accuracy in distinguishing lesions from normal skin, crucial for delineating tumor borders, was obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Likelihood ratios with confidence: Sample size estimation for diagnostic test studies
Simel, D. L., Samsa, G. P., & Matchar, D. B. (1991) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(91)90128-v · Cited by 932
Using optical coherence tomography to evaluate skin sun damage and precancer
Korde, V. R., Bonnema, G. T., Xu, W., Krishnamurthy, C., Ranger‐Moore, J., Saboda, K., Slayton, L. D., Salasche, S. J., Warneke, J. A., Alberts, D. S., et al. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20573 · Cited by 145
Cited by
von Braunmühl, T. (2015) · Der Hautarzt · doi:10.1007/s00105-015-3607-z · Cited by 1,033
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Optical coherence tomography in dermatology
Sattler, E., Kästle, R., & Welzel, J. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.6.061224 · Cited by 283
Dynamic Optical Coherence Tomography in Dermatology
Ulrich, M., Themstrup, L., de Carvalho, N., Manfredi, M., Grana, C., Ciardo, S., Kästle, R., Holmes, J., Whitehead, R., Jemec, G. B. E., et al. (2016) · Dermatology · doi:10.1159/000444706 · Cited by 230
Self-citationAdvances in optical coherence tomography in dermatology—a review
Olsen, J., Holmes, J., & Jemec, G. B. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.4.040901 · Cited by 165
Self-citation
Metadata
- Authors
- MOGENSEN, M., JOERGENSEN, T. M., NÜRNBERG, B. M., MORSY, H. A., THOMSEN, J. B., THRANE, L., & JEMEC, G. B. E.
- Venue
- Dermatologic Surgery
- Published
- 2009-06
- Volume
- 35
- Issue
- 6
- Pages
- 965-972
- ISSN
- 1076-0512 (ISSN-L)
- OpenAlex
- W2015186058
- Cited by
- 205
- References
- 2
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Optical Coherence Tomography Imaging in the Diagnosis of Non-Melanoma Skin Cancer and Benign Lesions Versus Normal Skin: Observer-Blinded Evaluation by Dermatologists and Pathologists. https://app.cochat.ai/papers/10.1111/j.1524-4725.2009.01164.x
- The paper
- MOGENSEN, M., JOERGENSEN, T. M., NÜRNBERG, B. M., MORSY, H. A., THOMSEN, J. B., THRANE, L., & JEMEC, G. B. E. (2009). Assessment of Optical Coherence Tomography Imaging in the Diagnosis of Non-Melanoma Skin Cancer and Benign Lesions Versus Normal Skin: Observer-Blinded Evaluation by Dermatologists and Pathologists. Dermatologic Surgery. https://doi.org/10.1111/j.1524-4725.2009.01164.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.