Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 621

The DOI matches its Crossref record.

Optical coherence tomography in dermatology: a review

Welzel, Julia·2001·Skin Research and Technology

Abstract

Background/aims: Optical coherence tomography (OCT) is a non‐invasive technique for morphological investigation of tissue. Since its development in the late 1980s it is mainly used as a diagnostic tool in ophthalmology. For examination of a highly scattering tissue like the skin, it was necessary to modify the method. Early studies on the value of OCT for skin diagnosis gave promising results. Methods: The OCT technique is based on the principle of Michelson interferometry. The light sources used for OCT are low coherent superluminescent diodes operating at a wavelength of about 1300 nm. OCT provides two‐dimensional images with a scan length of a few millimeters (mm), a resolution of about 15 μm and a maximum detection depth of 1.5 mm. The image acquisition can be performed nearly in real time. The measurement is non‐invasive and with no side effects. Results: The in vivo OCT images of human skin show a strong scattering from tissue with a few layers and some optical inhomogeneities. The resolution enables the visualization of architectural changes, but not of single cells. In palmoplantar skin, the thick stratum corneum is visible as a low‐scattering superficial well defined layer with spiral sweat gland ducts inside. The epidermis can be distinguished from the dermis. Adnexal structures and blood vessels are low‐scattering regions in the upper dermis. Skin tumors show a homogenous signal distribution. In some cases, tumor borders to healthy skin are detectable. Inflammatory skin diseases lead to changes of the OCT image, such as thickening of the epidermis and reduction of the light attenuation in the dermis. A quantification of treatment effects, such as swelling of the horny layer due to application of a moisturizer, is possible. Repeated measurements allow a monitoring of the changes over time. Conclusion: OCT is a promising new bioengineering method for investigation of skin morphology. In some cases it may be useful for diagnosis of skin diseases. Because of its non‐invasive character, the technique allows monitoring of inflammatory diseases over time. An objective quantification of the efficacy and tolerance of topical treatment is also possible. Due to the high resolution and simple application, OCT is an interesting addition to other morphological techniques in dermatology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1034/j.1600-0846.2001.007001001.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 621

Metadata

Authors
Welzel, J.
Venue
Skin Research and Technology
Publisher
Wiley
Published
2001-02
Volume
7
Issue
1
Pages
1-9
ISSN
  • 0909-752X (ISSN-L)
  • 1600-0846
OpenAlex
W2007675231
Cited by
621
References
0
FWCI
12.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optical coherence tomography in dermatology: a review. https://app.cochat.ai/papers/10.1034/j.1600-0846.2001.007001001.x
The paper
Welzel, J. (2001). Optical coherence tomography in dermatology: a review. Skin Research and Technology. https://doi.org/10.1034/j.1600-0846.2001.007001001.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.