Nexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The Finapres methodology offers continuous measurement of blood pressure (BP) in a noninvasive manner. The latest development using this methodology is the Nexfin monitor. The present study evaluated the accuracy of Nexfin noninvasive arterial pressure (NAP) compared with auscultatory BP measurements (Riva-Rocci/Korotkoff, RRK). METHODS: In supine subjects NAP was compared to RRK, performed by two observers using an electronic stethoscope with double earpieces. Per subject, three NAP-RRK differences were determined for systolic and diastolic BP, and bias and precision of differences were expressed as median (25th, 75th percentiles). Within-subject precision was defined as the (25th, 75th percentiles) after removing the average individual difference. RESULTS: A total of 312 data sets of NAP and RRK for systolic and diastolic BP from 104 subjects (aged 18-95 years, 54 males) were compared. RRK systolic BP was 129 (115, 150), and diastolic BP was 80 (72, 89), NAP-RRK differences were 5.4 (-1.7, 11.0) mm Hg and -2.5 (-7.6, 2.3) mm Hg for systolic and diastolic BP, respectively; within-subject precisions were (-2.2, 2.3) and (-1.6, 1.5) mm Hg, respectively. CONCLUSION: Nexfin provides accurate measurement of BP with good within-subject precision when compared to RRK.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines on management (diagnosis and treatment) of syncope
Brignole, M. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2739 · Cited by 951
Cited by
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®
Martina, J. R., Westerhof, B. E., van Goudoever, J., de Beaumont, E. M. F. H., Truijen, J., Kim, Y.-S., Immink, R. V., Jöbsis, D. A., Hollmann, M. W., Lahpor, J. R., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31824f94ed · Cited by 292
Self-citationPeter, L., Noury, N., & Cerny, M. (2014) · IRBM · doi:10.1016/j.irbm.2014.07.002 · Cited by 261
Antiadrenergic autoimmunity in postural tachycardia syndrome
Fedorowski, A., Li, H., Yu, X., Koelsch, K. A., Harris, V. M., Liles, C., Murphy, T. A., Quadri, S. M. S., Scofield, R. H., Sutton, R., et al. (2017) · EP Europace · doi:10.1093/europace/euw154 · Cited by 151
“The patients’ haemodynamic parameters and electrocardiogram were monitored using a non-invasive beat-to-beat measurement device (Nexfin, BMEYE, Amsterdam, the Netherlands).(13) Study participants were instructed to fast for 2 h before the test, and they were allowed to drink water ad libitum.”
MethodExercise blood pressure: Clinical relevance and correct measurement
Sharman, J. E., & LaGerche, A. (2015) · Journal of Human Hypertension · doi:10.1038/jhh.2014.84 · Cited by 142
Novel cardiovascular biomarkers in unexplained syncopal attacks: the SYSTEMA cohort
Fedorowski, A., Burri, P., Struck, J., Juul‐Möller, S., & Melander, O. (2013) · Journal of Internal Medicine · doi:10.1111/joim.12043 · Cited by 62
Smits, M. M., Muskiet, M. H. A., Tonneijck, L., Hoekstra, T., Kramer, M. H. H., Diamant, M., & van Raalte, D. H. (2016) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12843 · Cited by 60
Orthostatic Changes in Hemodynamics and Cardiovascular Biomarkers in Dysautonomic Patients
Nilsson, D., Sutton, R., Tas, W., Burri, P., Melander, O., & Fedorowski, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0128962 · Cited by 54
“Beat-to-beat blood pressure (BP) and electrocardiogram (ECG) were continuously monitored using a noninvasive validated method (Nexfin monitor, BMEYE, The Netherlands) [13], and subsequently analyzed offline using a dedicated program provided by the monitor manufacturer.”
Syndromes of orthostatic intolerance and syncope in young adults
Hamrefors, V., Spahic, J. M., Nilsson, D., Senneby, M., Sutton, R., Melander, O., & Fedorowski, A. (2017) · Open Heart · doi:10.1136/openhrt-2016-000585 · Cited by 23
Metadata
- Authors
- Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01-29
- Volume
- 22
- Issue
- 4
- Pages
- 378-383
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2024775988
- Cited by
- 222
- References
- 1
- FWCI
- 11.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.