CoChat

Aortic Augmentation Index: Reference Values in a Large Unselected Population by Means of the SphygmoCor Device

Janner, J. H., Godtfredsen, N. S., Ladelund, S., Vestbo, J., Prescott, E. · 2010 · American Journal of Hypertension
Cited by 126

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Arterial stiffness and pulse wave reflection are associated with cardiovascular disease (CVD). Pulse wave analyses (PWAs) allow the estimation of the central augmentation index (AIx), a measurement of pulse wave reflection. To understand the predictive role of AIx, reference values for AIx are needed. METHODS: This population study is based on 4,561 subjects from The Copenhagen City Heart Study, an ongoing epidemiological survey started in 1976, including subjects randomly chosen from the population in Copenhagen, Denmark. We calculated and internally validated reference values of AIx measured by the SphygmoCor device in a cohort without known CVD or diabetes, and with low risk of CVD according to HeartScore using gender-specific multiple regression analyses adjusting for age, heart rate, and height. RESULTS: AIx was significantly higher in women than in men, 30% vs. 22%, (P < 0.001) and the increase in AIx with age was curvilinear. There were 972 subjects in the low-risk cohort with mean AIx 28% in women (N = 565) and 18% in men (N = 407) (P < 0.001). We report the following internally validated reference equations for AIx: men: AIx = 79.20 + 0.63 (age) - 0.002 (age(2)) - 0.28 (heart rate) - 0.39 (height). Women: AIx = 56.28 + 0.90 (age) - 0.005 (age(2)) - 0.34 (heart rate) - 0.24 (height). AIx appeared to increase with increasing risk of CVD according to HeartScore. CONCLUSIONS: We report a novel and internally validated gender-specific equation including age, heart rate, and height to calculate reference values for AIx.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajh.2009.234

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 126

Metadata

Authors
Janner, J. H., Godtfredsen, N. S., Ladelund, S., Vestbo, J., & Prescott, E.
Venue
American Journal of Hypertension
Published
2010-02-01
Volume
23
Issue
2
Pages
180-185
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W2114828612
Cited by
126
References
8
FWCI
3.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Aortic Augmentation Index: Reference Values in a Large Unselected Population by Means of the SphygmoCor Device. https://app.cochat.ai/papers/10.1038/ajh.2009.234
The paper
Janner, J. H., Godtfredsen, N. S., Ladelund, S., Vestbo, J., & Prescott, E. (2010). Aortic Augmentation Index: Reference Values in a Large Unselected Population by Means of the SphygmoCor Device. American Journal of Hypertension. https://doi.org/10.1038/ajh.2009.234

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.