Evaluation of DXA against the four-component model of body composition in obese children and adolescents aged 5–21 years
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background:Body composition is increasingly measured in pediatric obese patients. Although dual-energy X-ray absorptiometry (DXA) is widely available, and is precise, its accuracy for body composition assessment in obese children remains untested.Objective:We aimed to evaluate DXA against the four-component (4C) model in obese children and adolescents in both cross-sectional and longitudinal contexts.Design:Body composition was measured by DXA (Lunar Prodigy) and the 4C model in 174 obese individuals aged 5–21 years, of whom 66 had a second measurement within 1.4 years. The Bland–Altman method was used to assess agreement between techniques for baseline body composition and change therein.Results:A significant minority of individuals (n=21) could not be scanned successfully due to their large size. At baseline, in 153 individuals with complete data, DXA significantly overestimated fat mass (FM; Δ=0.9, s.d. 2.1 kg, P<0.0001) and underestimated lean mass (LM; Δ=−1.0, s.d. 2.1 kg, P<0.0001). Multiple regression analysis showed that gender, puberty status, LM and FM were associated with the magnitude of the bias. In the longitudinal study of 51 individuals, the mean bias in change in fat or LM did not differ significantly from zero (FM: Δ=−0.02, P=0.9; LM: Δ=0.04, P=0.8), however limits of agreement were wide (FM: ±3.2 kg; LM: ±3.0 kg). The proportion of variance in the reference values explained by DXA was 76% for change in FM and 43% for change in LM.Conclusions:There are limitations to the accuracy of DXA using Lunar Prodigy for assessing body composition or changes therein in obese children. The causes of differential bias include variability in the magnitude of tissue masses, and stage of pubertal development. Further work is required to evaluate this scenario for other DXA models and manufacturers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Percent body fat via DEXA: comparison with a four-compartment model
van der Ploeg, G. E., Withers, R. T., & Laforgia, J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00436.2002 · Cited by 163
Cited by
Simmonds, M., Burch, J., Llewellyn, A., Griffiths, C., Yang, H., Owen, C., Duffy, S., & Woolacott, N. (2015) · Health Technology Assessment · doi:10.3310/hta19430 · Cited by 381
Suetta, C., Haddock, B., Alcazar, J., Noerst, T., Hansen, O. M., Ludvig, H., Kamper, R. S., Schnohr, P., Prescott, E., Andersen, L. L., et al. (2019) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12477 · Cited by 293
Wells, J. C., Williams, J. E., Chomtho, S., Darch, T., Grijalva-Eternod, C., Kennedy, K., Haroun, D., Wilson, C., Cole, T. J., & Fewtrell, M. S. (2012) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.112.036970 · Cited by 207
“Therefore, although the absolute accuracy of DXA remains imperfect (42, 45, 46), its use for categorizing relative fat and fat-free masses on the basis of whole-body measurement appears the best simpler option if the 4Cmodel is not available.”
BackgroundSelf-citationFreedman, D. S., Horlick, M., & Berenson, G. S. (2013) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.065961 · Cited by 152
Imboden, M. T., Swartz, A. M., Finch, H. W., Harber, M. P., & Kaminsky, L. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0176161 · Cited by 75
“Hologic and GE-Healthcare are the two dominant DXA manufacturers, which have been validated against criterion 4-compartment models [13, 14].”
MethodJiménez, A., Omaña, W., Flores, L., Coves, M. J., Bellido, D., Perea, V., & Vidal, J. (2012) · Obesity Surgery · doi:10.1007/s11695-011-0570-3 · Cited by 40
Gutiérrez-Marín, D., Escribano, J., Closa-Monasterolo, R., Ferré, N., Venables, M., Singh, P., Wells, J. C., Muñoz-Hernando, J., Zaragoza-Jordana, M., Gispert-Llauradó, M., et al. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2021.02.001 · Cited by 28
Self-citationKulovitz, M. G., Kolkmeyer, D., Conn, C. A., Cohen, D. A., & Ferraro, R. T. (2014) · Nutrition · doi:10.1016/j.nut.2013.06.008 · Cited by 15
Metadata
- Authors
- Wells, J. C. K., Haroun, D., Williams, J. E., Wilson, C., Darch, T., Viner, R. M., Eaton, S., & Fewtrell, M. S.
- Venue
- International Journal of Obesity
- Published
- 2010-01-12
- Volume
- 34
- Issue
- 4
- Pages
- 649-655
- ISSN
- 0307-0565 (ISSN-L)
- 1476-5497
- OpenAlex
- W1999216656
- Cited by
- 63
- References
- 2
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.