Blood Flow in Single Surface Arterioles and Venules on the Mouse Somatosensory Cortex Measured with Videomicroscopy, Fluorescent Dextrans, Nonoccluding Fluorescent Beads, and Computer-Assisted Image Analysis
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Cortical surface vessels were monitored through closed cranial windows with an epifluorescence microscope and SIT or ICCD cameras. Fluorescent dextrans or 1.3 μm latex beads were injected into the contralateral jugular vein for plasma labeling and for vascular transits. For close arterial transits, these tracers or physiological saline were injected into the ipsilateral external carotid artery. AVTTs were calculated from intensity differences of tracers between a branch of the MCA and a vein draining the same cortical region over time. AVTTs for saline dilutions of RBCs were significantly shorter (0.73 times) than for dextrans. Both dextrans and beads distributed with plasma. With FITC–dextran, inner diameters of arterioles and venules averaged 6 μm larger than hemoglobin under green light. This difference was likely due to the segregation of red blood cells and plasma during flow. Velocities of individual fluorescent beads were measured in pial vessels by strobe epi-illumination. Plots of bead velocities against radial position in arterioles were blunted parabolas. Peak shear rates in the marginal layer next to the vessel walls were determined directly from bead tracks in arterioles ( D = 21–71 μm) and were 1.32 times the Poiseuille estimate. The calculated peak wall shear stress was 39 ± 14 dyn/cm 2 (mean ± SD) for these arterioles but was probably severalfold greater in the smallest terminal pial arterioles. V max near the axes of arterioles increased with D +0.5 . The calculated peak wall shear rate was highest in small arterioles and decreased with D −0.5 . The calculated flow Q increased with D +2.5 . These methods permit direct, simultaneous, dynamic measurements on multiple identified cerebral microvessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonoxidative Glucose Consumption During Focal Physiologic Neural Activity
Fox, P. T., Raichle, M. E., Mintun, M. A., & Dence, C. (1988) · Science · doi:10.1126/science.3260686 · Cited by 1,796
Activation of Extrastriate and Frontal Cortical Areas by Visual Words and Word-Like Stimuli
Petersen, S. E., Fox, P. T., Snyder, A. Z., & Raichle, M. E. (1990) · Science · doi:10.1126/science.2396097 · Cited by 821
Cited by
Swain, R. A., Harris, A. B., Wiener, E. C., Dutka, M. V., Morris, H. D., Theien, B. E., Konda, S., Engberg, K., Lauterbur, P. C., & Greenough, W. T. (2003) · Neuroscience · doi:10.1016/s0306-4522(02)00664-4 · Cited by 655
Linear coupling between cerebral blood flow and oxygen consumption in activated human cortex
Hoge, R. D., Atkinson, J., Gill, B., Crelier, G. R., Marrett, S., & Pike, G. B. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9403 · Cited by 563
Two-Photon Microscopy as a Tool to Study Blood Flow and Neurovascular Coupling in the Rodent Brain
Shih, A. Y., Driscoll, J. D., Drew, P. J., Nishimura, N., Schaffer, C. B., & Kleinfeld, D. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.196 · Cited by 458
Penetrating arterioles are a bottleneck in the perfusion of neocortex
Nishimura, N., Schaffer, C. B., Friedman, B., Lyden, P. D., & Kleinfeld, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609551104 · Cited by 367
Cox, S. B., Woolsey, T. A., & Rovainen, C. M. (1993) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1993.113 · Cited by 198
Self-citation
Metadata
- Authors
- Rovainen, C. M., Woolsey, T. A., Blocher, N. C., Wang, D.-B., & Robinson, O. F.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 1993-05
- Volume
- 13
- Issue
- 3
- Pages
- 359-371
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2028959463
- Cited by
- 80
- References
- 2
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood Flow in Single Surface Arterioles and Venules on the Mouse Somatosensory Cortex Measured with Videomicroscopy, Fluorescent Dextrans, Nonoccluding Fluorescent Beads, and Computer-Assisted Image Analysis. https://app.cochat.ai/papers/10.1038/jcbfm.1993.49
- The paper
- Rovainen, C. M., Woolsey, T. A., Blocher, N. C., Wang, D.-B., & Robinson, O. F. (1993). Blood Flow in Single Surface Arterioles and Venules on the Mouse Somatosensory Cortex Measured with Videomicroscopy, Fluorescent Dextrans, Nonoccluding Fluorescent Beads, and Computer-Assisted Image Analysis. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1993.49
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.