Cortical Depth-Dependent Temporal Dynamics of the BOLD Response in the Human Brain
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Recent animal studies at high field have shown that blood oxygen level-dependent (BOLD) contrast can be specific to the laminar vascular architecture of the cortex, by differences in its temporal dynamics in reference to cortical depth. In this study, we characterize the temporal dynamics of the hemodynamic response (HDR) across cortical depth in the human primary motor and visual cortex, at 7T and using very short stimuli and with high spatial and temporal resolution. We find that the shape and temporal dynamics of the HDR changed in an orderly manner across cortical depth. Compared with the pial vasculature, HDRs in deeper gray matter are significantly faster in onset time (by ∼ 0.5 second) and peak time (∼2 seconds), and are narrower (by ∼1 second) and with smaller amplitude, in line with the known vascular organization across cortical depth and the transit of deoxygenated blood through the vasculature. The width of the HDR in deeper gray matter was as short as 2.1 seconds, indicating that neurovascular coupling takes place at a shorter timescale than previously reported in the human brain. These findings open the possibility to probe layer-specific hemodynamics and neurovascular coupling mechanisms in human gray matter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast robust automated brain extraction
Smith, S. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10062 · Cited by 10,496
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551 · cited 2×
“Even though the ensuing changes in hemodynamics are related to neuronal activity (Logothetis et al, 2001), both the spatial and temporal extent of the hemodynamic response (HDR) is dispersed due to the vascular organization and dynamics, resulting in inaccurate mapping onto neuronal activity.”
BackgroundOgawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772 · cited 3×
“Any remaining extravascular contamination from the pial veins would disappear rapidly with distance to the vessel; in the worst case scenario it drops off by a factor of four at a distance of half the vessel diameter (Ogawa et al, 1993).”
BackgroundUludağ, K., Müller-Bierl, B., & Uğurbil, K. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.051 · Cited by 450 · cited 4×
“This was achieved by capitalizing on the advantages of 7 T in terms of contrast-to-noise ratio and resolution (Pfeuffer et al, 2002), minimal intravascular contribution (Uludag et al, 2009; Yacoub et al, 2001), and fast sampling of the BOLD response.”
BackgroundMethodInfluentialImaging brain function in humans at 7 Tesla
Yacoub, E., Shmuel, A., Pfeuffer, J., Van De Moortele, P., Adriany, G., Andersen, P., Vaughan, J. T., Merkle, H., Ugurbil, K., & Hu, X. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1080 · Cited by 448 · cited 2×
“This was achieved by capitalizing on the advantages of 7 T in terms of contrast-to-noise ratio and resolution (Pfeuffer et al, 2002), minimal intravascular contribution (Uludag et al, 2009; Yacoub et al, 2001), and fast sampling of the BOLD response.”
BackgroundMethodTurner, R. (2002) · NeuroImage · doi:10.1006/nimg.2002.1082 · Cited by 365 · cited 2×
“This spatiotemporal heterogeneity of the BOLD response matched the known vascular organization across cortical depth (Duvernoy et al, 1981), which is expected to be closely related to functional organization in the human cerebral cortex (Friston et al, 1994; Gati et al, 1997; Turner, 2002).”
Background
Cited by
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Kraus, T., Kiess, O., Hösl, K., Terekhin, P., Kornhuber, J., & Forster, C. (2013) · Brain Stimulation · doi:10.1016/j.brs.2013.01.011 · Cited by 301
Cell type specificity of neurovascular coupling in cerebral cortex
Uhlirova, H., Kılıç, K., Tian, P., Thunemann, M., Desjardins, M., Saisan, P. A., Sakadžić, S., Ness, T. V., Mateo, C., Cheng, Q., et al. (2016) · eLife · doi:10.7554/elife.14315 · Cited by 245
“…of the dilation latency and time-to-peak down to the infragranular layers is in agreement with laminar resolved functional Magnetic Resonance Imaging (fMRI) in human (Siero et al., 2011) but at odds with a recent high resolution fMRI in the rat that used a line-scanning method (Yu et al., 2014).”
ResultLayer-specific fMRI reflects different neuronal computations at different depths in human V1
Olman, C. A., Harel, N., Feinberg, D. A., He, S., Zhang, P., Ugurbil, K., & Yacoub, E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0032536 · Cited by 194
Deciphering laminar-specific neural inputs with line-scanning fMRI
Yu, X., Qian, C., Chen, D.-Y., Dodd, S. J., & Koretsky, A. P. (2014) · Nature Methods · doi:10.1038/nmeth.2730 · Cited by 173
Metadata
- Authors
- Siero, J. C., Petridou, N., Hoogduin, H., Luijten, P. R., & Ramsey, N. F.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2011-04-20
- Volume
- 31
- Issue
- 10
- Pages
- 1999-2008
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2117301765
- Cited by
- 128
- References
- 6
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.