The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Quantitative Tissue Ph Measurement during Cerebral Ischemia Using Amine and Amide Concentration-Independent Detection (AACID) with MRI
Open accessAbstract
Tissue pH is an indicator of altered cellular metabolism in diseases including stroke and cancer. Ischemic tissue often becomes acidic due to increased anaerobic respiration leading to irreversible cellular damage. Chemical exchange saturation transfer (CEST) effects can be used to generate pH-weighted magnetic resonance imaging (MRI) contrast, which has been used to delineate the ischemic penumbra after ischemic stroke. In the current study, a novel MRI ratiometric technique is presented to measure absolute pH using the ratio of CEST-mediated contrast from amine and amide protons: amine/amide concentration-independent detection (AACID). Effects of CEST were observed at 2.75 parts per million (p.p.m.) for amine protons and at 3.50 p.p.m. for amide protons downfield (i.e., higher frequency) from bulk water. Using numerical simulations and in vitro MRI experiments, we showed that pH measured using AACID was independent of tissue relaxation time constants, macromolecular magnetization transfer effects, protein concentration, and temperature within the physiologic range. After in vivo pH calibration using phosphorus (31 P) magnetic resonance spectroscopy (31 P-MRS), local acidosis is detected in mouse brain after focal permanent middle cerebral artery occlusion. In summary, our results suggest that AACID represents a noninvasive method to directly measure the spatial distribution of absolute pH in vivo using CEST MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosenberg, G. A. (1999) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(99)70003-4 · Cited by 278
Cited by
APT‐weighted MRI: Techniques, current neuro applications, and challenging issues
Zhou, J., Heo, H., Knutsson, L., van Zijl, P. C. M., & Jiang, S. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26645 · Cited by 345
Clinical applications of chemical exchange saturation transfer (CEST) MRI
Jones, K. M., Pollard, A. C., & Pagel, M. D. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25838 · Cited by 287
Noninvasive Detection of Extracellular pH in Human Benign and Malignant Liver Tumors Using CEST MRI
Tang, Y., Xiao, G., Shen, Z., Zhuang, C., Xie, Y., Zhang, X., Yang, Z., Guan, J., Shen, Y., Chen, Y., et al. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.578985 · Cited by 56
Imaging the accumulation and suppression of tau pathology using multiparametric MRI
Holmes, H. E., Colgan, N., Ismail, O., Ma, D., Powell, N. M., O'Callaghan, J. M., Harrison, I. F., Johnson, R. A., Murray, T. K., Ahmed, Z., et al. (2016) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2015.12.001 · Cited by 51
Xiao, P., Huang, J., Han, X., Cheu, J. W. S., Liu, Y., Law, L. H., Lai, J. H. C., Li, J., Park, S. W., Wong, C. C. L., et al. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c10493 · Cited by 14
Metadata
- Authors
- McVicar, N., Li, A. X., Gonçalves, D. F., Bellyou, M., Meakin, S. O., Prado, M. A., & Bartha, R.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2014-02-05
- Volume
- 34
- Issue
- 4
- Pages
- 690-698
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W1986357760
- Cited by
- 168
- References
- 1
- FWCI
- 13.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.