Tolerability of Two Sequential Electroporation Treatments Using MedPulser DNA Delivery System (DDS) in Healthy Adults
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Immunotherapy against infectious agents and malignant tumors requires efficient priming of effector cells through direct expression and/or efficient cross-presentation of antigens by antigen-presenting cells. Electroporation is a new procedure aimed at transiently increasing cell membrane permeability and direct delivery of antigen or antigen-encoding nucleic acids inside targeted cells. We evaluated the tolerability including compliance with repeated electroporation treatments using MedPulser DDS in 24 healthy adults. Pain severity was evaluated at time of electroporation treatment, and at 1, 5, 10, and 20 minutes, and 24 hours thereafter, using two clinically validated questionnaires: McGill Pain Questionnaire (MPQ) (Present Pain Intensity) and Brief Pain Inventory (BPI). Electroporation treatments were generally well tolerated. Twenty-two out of 24 subjects returned for the second electroporation treatment 14 days after first treatment. Only two subjects reported a treatment-related systemic adverse experience following either electroporation application. For both pain assessment tools, maximum pain and/or discomfort were mostly reported immediately (within 5 minutes) after electroporation; Furthermore, no difference was observed when comparing peak-pain scores after first and second electroporation treatments. This study supports the clinical application of MedPulser DDS for the improvement of antigen-induced immune responses for prophylactic or therapeutic vaccines, especially in gene-based therapies for cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Distribution of DNA Vaccines Determines Their Immunogenicity After Intramuscular Injection in Mice
Dupuis, M., Denis-Mize, K., Woo, C., Goldbeck, C., Selby, M. J., Chen, M., Otten, G. R., Ulmer, J. B., Donnelly, J. J., Ott, G., et al. (2000) · The Journal of Immunology · doi:10.4049/jimmunol.165.5.2850 · Cited by 327
Cited by
Photodynamic therapy – mechanisms, photosensitizers and combinations
Kwiatkowski, S., Knap, B., Przystupski, D., Saczko, J., Kędzierska, E., Knap-Czop, K., Kotlińska, J., Michel, O., Kotowski, K., & Kulbacka, J. (2018) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.07.049 · Cited by 2,173
Electroporation delivery of DNA vaccines: prospects for success
Sardesai, N. Y., & Weiner, D. B. (2011) · Current Opinion in Immunology · doi:10.1016/j.coi.2011.03.008 · Cited by 416
“The predominant adverse findings (grade 1/2) associated with the IMEP procedure is transient pain that rapidly decays to background within 25 – 30 minutes [64,65].”
BackgroundPolymer multilayer tattooing for enhanced DNA vaccination
DeMuth, P. C., Min, Y., Huang, B., Kramer, J. A., Miller, A. D., Barouch, D. H., Hammond, P. T., & Irvine, D. J. (2013) · Nature Materials · doi:10.1038/nmat3550 · Cited by 277
Clinical potential of electroporation for gene therapy and DNA vaccine delivery
Lambricht, L., Lopes, A., Kos, S., Sersa, G., Préat, V., & Vandermeulen, G. (2016) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2016.1121990 · Cited by 230
“5 cm depth IT (no more information available) IM injection pain Transient local reaction One minute Few minutes [30]”
BackgroundChen, X., Fernando, G. J. P., Crichton, M. L., Flaim, C., Yukiko, S. R., Fairmaid, E. J., Corbett, H. J., Primiero, C. A., Ansaldo, A. B., Frazer, I. H., et al. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.02.026 · Cited by 180
“The electroporation process causes pain and discomfort to patients [18-20].”
Background
Metadata
- Authors
- Wallace, M., Evans, B., Woods, S., Mogg, R., Zhang, L., Finnefrock, A. C., Rabussay, D., Fons, M., Mallee, J., Mehrotra, D., Schödel, F., & Musey, L.
- Venue
- Molecular Therapy
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 17
- Issue
- 5
- Pages
- 922-928
- ISSN
- 1525-0016 (ISSN-L)
- OpenAlex
- W2028453932
- Cited by
- 59
- References
- 1
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.