The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A membrane-access mechanism of ion channel inhibition by voltage sensor toxins from spider venom
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ion Channels/Excitable Membranes
(2011) · SpringerReference · doi:10.1007/springerreference_33998 · Cited by 4,034
X-ray structure of a voltage-dependent K+ channel
Jiang, Y., Lee, A., Chen, J., Ruta, V., Cadene, M., Chait, B. T., & MacKinnon, R. (2003) · Nature · doi:10.1038/nature01580 · Cited by 1,797
Self-citationHandbook of Biological Physics
Robillard, G. T., de Boer, H. F., Haris, P. I., Meijberg, W., Dijkstra, D. S., Schuurman‐Wolters, G. K., Hoeve-Duurkens, R. T., Chapman, D., & Broos, J. (1996) · Cited by 927
Miller, C., Moczydlowski, E., Latorre, R., & Phillips, M. (1985) · Nature · doi:10.1038/313316a0 · Cited by 795
The principle of gating charge movement in a voltage-dependent K+ channel
Jiang, Y., Ruta, V., Chen, J., Lee, A., & MacKinnon, R. (2003) · Nature · doi:10.1038/nature01581 · Cited by 781
Self-citationRevealing the Architecture of a K + Channel Pore Through Mutant Cycles with a Peptide Inhibitor
Hidalgo, P., & MacKinnon, R. (1995) · Science · doi:10.1126/science.7716527 · Cited by 438
Self-citationHugues, M., Romey, G., Duval, D., Vincent, J. P., & Lazdunski, M. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.4.1308 · Cited by 348
Spatial Localization of the K+ Channel Selectivity Filter by Mutant Cycle–Based Structure Analysis
Ranganathan, R., Lewis, J. H., & MacKinnon, R. (1996) · Neuron · doi:10.1016/s0896-6273(00)80030-6 · Cited by 295
Self-citationSingle Streptomyces lividans K+ Channels
Heginbotham, L., LeMasurier, M., Kolmakova-Partensky, L., & Miller, C. (1999) · The Journal of General Physiology · doi:10.1085/jgp.114.4.551 · Cited by 292
Garcia, M. L., Garcia-Calvo, M., Hidalgo, P., Lee, A., & MacKinnon, R. (1994) · Biochemistry · doi:10.1021/bi00188a012 · Cited by 269
Self-citation
Cited by
Destructive extraction of phospholipids from Escherichia coli membranes by graphene nanosheets
Tu, Y., Lv, M., Xiu, P., Huynh, T., Zhang, M., Castelli, M., Liu, Z., Huang, Q., Fan, C., Fang, H., et al. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2013.125 · Cited by 1,508
Structure and mechanism of the M2 proton channel of influenza A virus
Schnell, J. R., & Chou, J. J. (2008) · Nature · doi:10.1038/nature06531 · Cited by 1,067
TRPV1 structures in nanodiscs reveal mechanisms of ligand and lipid action
Gao, Y., Cao, E., Julius, D., & Cheng, Y. (2016) · Nature · doi:10.1038/nature17964 · Cited by 814
Voltage-gated potassium channels as therapeutic targets
Wulff, H., Castle, N. A., & Pardo, L. A. (2009) · Nature Reviews Drug Discovery · doi:10.1038/nrd2983 · Cited by 799
Ion Channel Voltage Sensors: Structure, Function, and Pathophysiology
Catterall, W. A. (2010) · Neuron · doi:10.1016/j.neuron.2010.08.021 · Cited by 568
Rodríguez de la Vega, R. C., & Possani, L. D. (2005) · Toxicon · doi:10.1016/j.toxicon.2005.09.006 · Cited by 372
Spider toxins activate the capsaicin receptor to produce inflammatory pain
Siemens, J., Zhou, S., Piskorowski, R., Nikai, T., Lumpkin, E. A., Basbaum, A. I., King, D., & Julius, D. (2006) · Nature · doi:10.1038/nature05285 · Cited by 359
Structural basis of Nav1.7 inhibition by an isoform-selective small-molecule antagonist
Ahuja, S., Mukund, S., Deng, L., Khakh, K., Chang, E., Ho, H., Shriver, S., Young, C., Lin, S., Johnson, J. P., et al. (2015) · Science · doi:10.1126/science.aac5464 · Cited by 319
Spider genomes provide insight into composition and evolution of venom and silk
Sanggaard, K. W., Bechsgaard, J. S., Fang, X., Duan, J., Dyrlund, T. F., Gupta, V., Jiang, X., Cheng, L., Fan, D., Feng, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms4765 · Cited by 307
How Does Voltage Open an Ion Channel?
Tombola, F., Pathak, M. M., & Isacoff, E. Y. (2006) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.21.020404.145837 · Cited by 303
Feeling the hidden mechanical forces in lipid bilayer is an original sense
Anishkin, A., Loukin, S. H., Teng, J., & Kung, C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1313364111 · Cited by 300
Sensing voltage across lipid membranes
Swartz, K. J. (2008) · Nature · doi:10.1038/nature07620 · Cited by 293
Judge, S. I. V., & Bever, C. T. (2006) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2005.10.006 · Cited by 268
Deconstructing voltage sensor function and pharmacology in sodium channels
Bosmans, F., Martin-Eauclaire, M.-F., & Swartz, K. J. (2008) · Nature · doi:10.1038/nature07473 · Cited by 261
GsMTx4: Mechanism of Inhibiting Mechanosensitive Ion Channels
Gnanasambandam, R., Ghatak, C., Yasmann, A., Nishizawa, K., Sachs, F., Ladokhin, A. S., Sukharev, S. I., & Suchyna, T. M. (2017) · Biophysical Journal · doi:10.1016/j.bpj.2016.11.013 · Cited by 258
Tang, Y., Zhao, C., Zhuang, Y., Zhong, A., Wang, M., Zhang, W., & Zhu, L. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1149336 · Cited by 67
Structural modeling of peptide toxin–ion channel interactions using RosettaDock
Mateos, D. L., & Yarov‐Yarovoy, V. (2023) · Proteins: Structure, Function, and Bioinformatics · doi:10.1002/prot.26474 · Cited by 4
Metadata
- Authors
- Lee, S.-Y., & MacKinnon, R.
- Venue
- Nature
- Published
- 2004-07
- Volume
- 430
- Issue
- 6996
- Pages
- 232-235
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2082531156
- Cited by
- 267
- References
- 23
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.