The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Single-ion quantum lock-in amplifier
Open accessAbstract
Quantum metrology uses tools from quantum information science to improve measurement signal-to-noise ratios. The challenge is to increase sensitivity while reducing susceptibility to noise, tasks that are often in conflict. Lock-in measurement is a detection scheme designed to overcome this difficulty by spectrally separating signal from noise. Here we report on the implementation of a quantum analogue to the classical lock-in amplifier. All the lock-in operations—modulation, detection and mixing—are performed through the application of non-commuting quantum operators to the electronic spin state of a single, trapped Sr+ ion. We significantly increase its sensitivity to external fields while extending phase coherence by three orders of magnitude, to more than one second. Using this technique, we measure frequency shifts with a sensitivity of 0.42 Hz Hz−1/2 (corresponding to a magnetic field measurement sensitivity of 15 pT Hz−1/2), obtaining an uncertainty of less than 10 mHz (350 fT) after 3,720 seconds of averaging. These sensitivities are limited by quantum projection noise and improve on other single-spin probe technologies by two orders of magnitude. Our reported sensitivity is sufficient for the measurement of parity non-conservation, as well as the detection of the magnetic field of a single electronic spin one micrometre from an ion detector with nanometre resolution. As a first application, we perform light shift spectroscopy of a narrow optical quadrupole transition. Finally, we emphasize that the quantum lock-in technique is generic and can potentially enhance the sensitivity of any quantum sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental issues in coherent quantum-state manipulation of trapped atomic ions
Wineland, D. J., Monroe, C., Itano, W. M., Leibfried, D., King, B. E., & Meekhof, D. M. (1998) · Journal of Research of the National Institute of Standards and Technology · doi:10.6028/jres.103.019 · Cited by 1,497
Frequency Ratio of Al+and Hg+Single-Ion Optical Clocks; Metrology at the 17th Decimal Place
Rosenband, T., Hume, D. B., Schmidt, P. O., Chou, C. W., Brusch, A., Lorini, L., Oskay, W. H., Drullinger, R. E., Fortier, T. M., Stalnaker, J. E., et al. (2008) · Science · doi:10.1126/science.1154622 · Cited by 1,450 · cited 2×
“is multiplied by either sin(2ˇf mt) or cos(2ˇf mt) and the two results are integrated over an integration window 3 T, I lock in= 1 T Z T 0 M(t) cos(2ˇf mt)dt Q lock in= 1 T Z T 0 M(t) sin(2ˇf mt)dt: (1) The signal S 0 is proportional to (I2 lock in + Q 2 lock in ) 1=2. The constant phase ’can be extracted by tan(’) =…”
BackgroundImprovement of Frequency Standards with Quantum Entanglement
Huelga, S. F., Macchiavello, C., Pellizzari, T., Ekert, A. K., Plenio, M. B., & Cirac, J. I. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.3865 · Cited by 999
Optimized dynamical decoupling in a model quantum memory
Biercuk, M. J., Uys, H., VanDevender, A. P., Shiga, N., Itano, W. M., & Bollinger, J. J. (2009) · Nature · doi:10.1038/nature07951 · Cited by 654
Handbook of frequency stability analysis
Riley, W. J., & Riley, W. J. (2008) · doi:10.6028/nist.sp.1065 · Cited by 586
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Magnetometry with nitrogen-vacancy defects in diamond
Rondin, L., Tetienne, J.-P., Hingant, T., Roch, J.-F., Maletinsky, P., & Jacques, V (2014) · Reports on Progress in Physics · doi:10.1088/0034-4885/77/5/056503 · Cited by 1,336
Nuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume
Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J. (2013) · Science · doi:10.1126/science.1231675 · Cited by 754
Coherent Sensing of a Mechanical Resonator with a Single-Spin Qubit
Kolkowitz, S., Bleszynski Jayich, A. C., Unterreithmeier, Q. P., Bennett, S. D., Rabl, P., Harris, J. G. E., & Lukin, M. D. (2012) · Science · doi:10.1126/science.1216821 · Cited by 395
Submillihertz magnetic spectroscopy performed with a nanoscale quantum sensor
Schmitt, S., Gefen, T., Stürner, F. M., Unden, T., Wolff, G., Müller, C., Scheuer, J., Naydenov, B., Markham, M., Pezzagna, S., et al. (2017) · Science · doi:10.1126/science.aam5532 · Cited by 359
Metadata
- Authors
- Kotler, S., Akerman, N., Glickman, Y., Keselman, A., & Ozeri, R.
- Venue
- Nature
- Published
- 2011-05
- Volume
- 473
- Issue
- 7345
- Pages
- 61-65
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2137807361
- Cited by
- 218
- References
- 5
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-ion quantum lock-in amplifier. https://app.cochat.ai/papers/10.1038/nature10010
- The paper
- Kotler, S., Akerman, N., Glickman, Y., Keselman, A., & Ozeri, R. (2011). Single-ion quantum lock-in amplifier. Nature. https://doi.org/10.1038/nature10010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.