The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
An integrated semiconductor device enabling non-optical genome sequencing
Open accessAbstract
The seminal importance of DNA sequencing to the life sciences, biotechnology and medicine has driven the search for more scalable and lower-cost solutions. Here we describe a DNA sequencing technology in which scalable, low-cost semiconductor manufacturing techniques are used to make an integrated circuit able to directly perform non-optical DNA sequencing of genomes. Sequence data are obtained by directly sensing the ions produced by template-directed DNA polymerase synthesis using all-natural nucleotides on this massively parallel semiconductor-sensing device or ion chip. The ion chip contains ion-sensitive, field-effect transistor-based sensors in perfect register with 1.2 million wells, which provide confinement and allow parallel, simultaneous detection of independent sequencing reactions. Use of the most widely used technology for constructing integrated circuits, the complementary metal-oxide semiconductor (CMOS) process, allows for low-cost, large-scale production and scaling of the device to higher densities and larger array sizes. We show the performance of the system by sequencing three bacterial genomes, its robustness and scalability by producing ion chips with up to 10 times as many sensors and sequencing a human genome. Progress towards cheaper and more compact DNA sequencing devices is limited by a number of factors, including the need for imaging technology. A new DNA sequencing technology that does away with optical readout, instead gathering sequence data by directly sensing hydrogen ions produced by template-directed DNA synthesis, offers a route to low cost and scalable sequencing on a massively parallel semiconductor-sensing device or ion chip. The reactions are performed using all natural nucleotides, and the individual ion-sensitive chips are disposable and inexpensive. The system has been used to sequence three bacterial genomes and a human genome: that of Gordon Moore of Moore's law fame.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA sequencing with chain-terminating inhibitors
Sanger, F., Nicklen, S., & Coulson, A. R. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.12.5463 · Cited by 68,572
Circos: An information aesthetic for comparative genomics
Krzywinski, M., Schein, J., Birol, İ., Connors, J., Gascoyne, R., Horsman, D., Jones, S. J., & Marra, M. A. (2009) · Genome Research · doi:10.1101/gr.092759.109 · Cited by 10,964
Genome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
Self-citationSequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066
Base-Calling of Automated Sequencer Traces Using Phred. I. Accuracy Assessment
Ewing, B., Hillier, L., Wendl, M. C., & Green, P. (1998) · Genome Research · doi:10.1101/gr.8.3.175 · Cited by 6,967
Cramming More Components onto Integrated Circuits (1965)
Moore, G. (2021) · Ideas That Created the Future · doi:10.7551/mitpress/12274.003.0027 · Cited by 6,241
Base-Calling of Automated Sequencer Traces Using Phred. II. Error Probabilities
Ewing, B., & Green, P. (1998) · Genome Research · doi:10.1101/gr.8.3.186 · Cited by 5,439
Environmental genome shotgun sequencing of the sargasso sea
Venter, J. C., Remington, K., Heidelberg, J. F., Halpern, A. L., Rusch, D., Eisen, J. A., Wu, D., Paulsen, I., Nelson, K. E., Nelson, W., et al. (2004) · Science · doi:10.1126/science.1093857 · Cited by 4,376
Microbial diversity in the deep sea and the underexplored “rare biosphere”
Sogin, M. L., Morrison, H. G., Huber, J. A., Welch, D. M., Huse, S. M., Neal, P. R., Arrieta, J. M., & Herndl, G. J. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605127103 · Cited by 3,701
Accurate whole human genome sequencing using reversible terminator chemistry
Bentley, D. R., Balasubramanian, S., Swerdlow, H. P., Smith, G. P., Milton, J., Brown, C. G., Hall, K. P., Evers, D. J., Barnes, C. L., Bignell, H. R., et al. (2008) · Nature · doi:10.1038/nature07517 · Cited by 3,684
Online Mendelian Inheritance in Man (OMIM), a knowledgebase of human genes and genetic disorders
Hamosh, A. (2004) · Nucleic Acids Research · doi:10.1093/nar/gki033 · Cited by 3,420
Reanalysis and revision of the Cambridge reference sequence for human mitochondrial DNA
Andrews, R. M., Kubacka, I., Chinnery, P. F., Lightowlers, R. N., Turnbull, D. M., & Howell, N. (1999) · Nature Genetics · doi:10.1038/13779 · Cited by 3,337
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
A Diarylquinoline Drug Active on the ATP Synthase of Mycobacterium tuberculosis
Andries, K., Verhasselt, P., Guillemont, J., Göhlmann, H. W. H., Neefs, J.-M., Winkler, H., Van Gestel, J., Timmerman, P., Zhu, M., Lee, E., et al. (2005) · Science · doi:10.1126/science.1106753 · Cited by 2,191
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Exome sequencing identifies the cause of a mendelian disorder
Ng, S. B., Buckingham, K. J., Lee, C., Bigham, A. W., Tabor, H. K., Dent, K. M., Huff, C. D., Shannon, P. T., Jabs, E. W., Nickerson, D. A., et al. (2010) · Nature Genetics · doi:10.1038/ng.499 · Cited by 1,957
The complete genome of an individual by massively parallel DNA sequencing
Wheeler, D. A., Srinivasan, M., Egholm, M., Shen, Y., Chen, L., McGuire, A., He, W., Chen, Y.-J., Makhijani, V., Roth, G. T., et al. (2008) · Nature · doi:10.1038/nature06884 · Cited by 1,838
Self-citationFluorescence detection in automated DNA sequence analysis
Smith, L. M., Sanders, J. Z., Kaiser, R. J., Hughes, P., Dodd, C., Connell, C. R., Heiner, C., Kent, S. B. H., & Hood, L. E. (1986) · Nature · doi:10.1038/321674a0 · Cited by 1,714
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
DNA sequencing of a cytogenetically normal acute myeloid leukaemia genome
Ley, T. J., Mardis, E. R., Ding, L., Fulton, B., McLellan, M. D., Chen, K., Dooling, D., Dunford-Shore, B. H., McGrath, S., Hickenbotham, M., et al. (2008) · Nature · doi:10.1038/nature07485 · Cited by 1,422
Accurate Multiplex Polony Sequencing of an Evolved Bacterial Genome
Shendure, J., Porreca, G. J., Reppas, N. B., Lin, X., McCutcheon, J. P., Rosenbaum, A. M., Wang, M. D., Zhang, K., Mitra, R. D., & Church, G. M. (2005) · Science · doi:10.1126/science.1117389 · Cited by 1,402
Accuracy and quality of massively parallel DNA pyrosequencing
Huse, S. M., Huber, J. A., Morrison, H. G., Sogin, M. L., & Welch, D. M. (2007) · Genome Biology · doi:10.1186/gb-2007-8-7-r143 · Cited by 1,282
Human Genome Sequencing Using Unchained Base Reads on Self-Assembling DNA Nanoarrays
Drmanac, R., Sparks, A. B., Callow, M. J., Halpern, A. L., Burns, N. L., Kermani, B. G., Carnevali, P., Nazarenko, I., Nilsen, G. B., Yeung, G., et al. (2010) · Science · doi:10.1126/science.1181498 · Cited by 1,212
Claesson, M. J., Wang, Q., O'Sullivan, O., Greene-Diniz, R., Cole, J. R., Ross, R. P., & O'Toole, P. W. (2010) · Nucleic Acids Research · doi:10.1093/nar/gkq873 · Cited by 980
Analysis of one million base pairs of Neanderthal DNA
Green, R. E., Krause, J., Ptak, S. E., Briggs, A. W., Ronan, M. T., Simons, J. F., Du, L., Egholm, M., Rothberg, J. M., Paunovic, M., et al. (2006) · Nature · doi:10.1038/nature05336 · Cited by 760
Self-citationWhole-Genome Sequencing in a Patient with Charcot–Marie–Tooth Neuropathy
Lupski, J. R., Reid, J. G., Gonzaga-Jauregui, C., Rio Deiros, D., Chen, D. C. Y., Nazareth, L., Bainbridge, M., Dinh, H., Jing, C., Wheeler, D. A., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0908094 · Cited by 759
McKernan, K. J., Peckham, H. E., Costa, G. L., McLaughlin, S. F., Fu, Y., Tsung, E. F., Clouser, C. R., Duncan, C., Ichikawa, J. K., Lee, C. C., et al. (2009) · Genome Research · doi:10.1101/gr.091868.109 · Cited by 528
Self-citationKloss-Brandstätter, A., Pacher, D., Schönherr, S., Weissensteiner, H., Binna, R., Specht, G., & Kronenberg, F. (2011) · Human Mutation · doi:10.1002/humu.21382 · Cited by 504
Complete Khoisan and Bantu genomes from southern Africa
Schuster, S. C., Miller, W., Ratan, A., Tomsho, L. P., Giardine, B., Kasson, L. R., Harris, R. S., Petersen, D. C., Zhao, F., Qi, J., et al. (2010) · Nature · doi:10.1038/nature08795 · Cited by 499
Electronic detection of DNA by its intrinsic molecular charge
Fritz, J., Cooper, E. B., Gaudet, S., Sorger, P. K., & Manalis, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232276699 · Cited by 443
Thomas, R. K., Nickerson, E., Simons, J. F., Jänne, P. A., Tengs, T., Yuza, Y., Garraway, L. A., LaFramboise, T., Lee, J. C., Shah, K., et al. (2006) · Nature Medicine · doi:10.1038/nm1437 · Cited by 361
Self-citationIon-sensitive field-effect transistors fabricated in a commercial CMOS technology
Bausells, J., Carrabina, J., Errachid, A., & Merlos, A. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00135-5 · Cited by 327
Genomic Sequencing of Pleistocene Cave Bears
Noonan, J. P., Hofreiter, M., Smith, D., Priest, J. R., Rohland, N., Rabeder, G., Krause, J., Detter, J. C., Pääbo, S., & Rubin, E. M. (2005) · Science · doi:10.1126/science.1113485 · Cited by 242
CMOS image sensors: State-of-the-art
Theuwissen, A. J. P. (2008) · Solid-State Electronics · doi:10.1016/j.sse.2008.04.012 · Cited by 180
Fabrication of a two-dimensional pH image sensor using a charge transfer technique
Hizawa, T., Sawada, K., Takao, H., & Ishida, M. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.01.056 · Cited by 122
DNA Sequencing Based on Intrinsic Molecular Charges
Sakata, T., & Miyahara, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503154 · Cited by 113
Purushothaman, S., Toumazou, C., & Ou, C.-P. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.06.069 · Cited by 106
Direct electrical detection of DNA synthesis
Pourmand, N., Karhánek, M., Persson, H. H. J., Webb, C. D., Lee, T. H., Zahradníková, A., & Davis, R. W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601184103 · Cited by 94
Matching the Transconductance Characteristics of CMOS ISFET Arrays by Removing Trapped Charge
Milgrew, M. J., & Cumming, D. R. S. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.916680 · Cited by 88
Self-citationMikolajick, T., Kühnhold, R., & Ryssel, H. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00166-4 · Cited by 74
A large transistor-based sensor array chip for direct extracellular imaging
Milgrew, M. J., Riehle, M. O., & Cumming, D. R. S. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.01.020 · Cited by 68
Self-citationA very large integrated pH-ISFET sensor array chip compatible with standard CMOS processes
Yeow, T. C. W., Haskard, M. R., Mulcahy, D. E., Seo, H. I., & Kwon, D. H. (1997) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(97)00207-4 · Cited by 58
Real-time monitoring of DNA polymerase reactions by a micro ISFET pH sensor
Sakurai, T., & Husimi, Y. (1992) · Analytical Chemistry · doi:10.1021/ac00041a040 · Cited by 46
Encapsulation of a liquid-sensing microchip using SU-8 photoresist
Hammond, P. A. (2004) · Microelectronic Engineering · doi:10.1016/j.mee.2004.03.071 · Cited by 32
DNA Sequencing Based on Intrinsic Molecular Charges
Sakata, T., & Miyahara, Y. (2006) · Angewandte Chemie · doi:10.1002/ange.200503154 · Cited by 6
Research works printed but not linked: 2
- Davies, K. The $1,000 Genome (Free Press, 2010)
- Milgrew, M., Hammond, P. & Cumming, D. The development of scalable sensor arrays using standard CMOS technology. Sens. Actuators B Chem. 103, 37–42 (2004) · DOI
Cited by
STAR: ultrafast universal RNA-seq aligner
Dobin, A., Davis, C. A., Schlesinger, F., Drenkow, J., Zaleski, C., Jha, S., Batut, P., Chaisson, M., & Gingeras, T. R. (2013) · Bioinformatics · doi:10.1093/bioinformatics/bts635 · Cited by 51,709
Fast gapped-read alignment with Bowtie 2
Langmead, B., & Salzberg, S. L. (2012) · Nature Methods · doi:10.1038/nmeth.1923 · Cited by 56,400
Klindworth, A., Pruesse, E., Schweer, T., Peplies, J., Quast, C., Horn, M., & Glöckner, F. O. (2013) · Nucleic Acids Research · doi:10.1093/nar/gks808 · Cited by 8,850
Coming of age: ten years of next-generation sequencing technologies
Goodwin, S., McPherson, J. D., & McCombie, W. R. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2016.49 · Cited by 4,352
Opportunities and challenges in long-read sequencing data analysis
Amarasinghe, S. L., Su, S., Dong, X., Zappia, L., Ritchie, M. E., & Gouil, Q. (2020) · Genome Biology · doi:10.1186/s13059-020-1935-5 · Cited by 2,530
Metadata
- Authors
- Rothberg, J. M., Hinz, W., Rearick, T. M., Schultz, J., Mileski, W., Davey, M., Leamon, J. H., Johnson, K., Milgrew, M. J., Edwards, M., Hoon, J., Simons, J. F., Marran, D., Myers, J. W., Davidson, J. F., Branting, A., Nobile, J. R., Puc, B. P., Light, D., Clark, T. A., Huber, M., Branciforte, J. T., Stoner, I. B., Cawley, S. E., Lyons, M., Fu, Y., Homer, N., Sedova, M., Miao, X., Reed, B., Sabina, J., Feierstein, E., Schorn, M., Alanjary, M., Dimalanta, E., Dressman, D., Kasinskas, R., Sokolsky, T., Fidanza, J. A., Namsaraev, E., McKernan, K. J., Williams, A., Roth, G. T., & Bustillo, J.
- Venue
- Nature
- Published
- 2011-07
- Volume
- 475
- Issue
- 7356
- Pages
- 348-352
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1988929438
- Cited by
- 2,172
- References
- 45
- FWCI
- 125.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Licence
- creativecommons.org/licenses/by-nc-sa/3.0/ (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.