High-resolution non-destructive three-dimensional imaging of integrated circuits
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Modern nanoelectronics has advanced to a point at which it is impossible to image entire devices and their interconnections non-destructively because of their small feature sizes and the complex three-dimensional structures resulting from their integration on a chip. This metrology gap implies a lack of direct feedback between design and manufacturing processes, and hampers quality control during production, shipment and use. Here we demonstrate that X-ray ptychography—a high-resolution coherent diffractive imaging technique—can create three-dimensional images of integrated circuits of known and unknown designs with a lateral resolution in all directions down to 14.6 nanometres. We obtained detailed device geometries and corresponding elemental maps, and show how the devices are integrated with each other to form the chip. Our experiments represent a major advance in chip inspection and reverse engineering over the traditional destructive electron microscopy and ion milling techniques. Foreseeable developments in X-ray sources, optics and detectors, as well as adoption of an instrument geometry optimized for planar rather than cylindrical samples, could lead to a thousand-fold increase in efficiency, with concomitant reductions in scan times and voxel sizes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
Sze, S. M., & Ng, K. K. (2006) · doi:10.1002/0470068329 · Cited by 14,627
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Self-citationFourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927
Ptychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926
Self-citationCMOS: Circuit Design, Layout, and Simulation
Baker, R. J. (2010) · doi:10.1002/9780470891179 · Cited by 709
Maximum-likelihood refinement for coherent diffractive imaging
Thibault, P., & Guizar-Sicairos, M. (2012) · New Journal of Physics · doi:10.1088/1367-2630/14/6/063004 · Cited by 416
Self-citationHuang, X., Lee, W.-C., Kuo, C., Hisamoto, D., Chang, L., Kedzierski, J., Anderson, E., Takeuchi, H., Choi, Y.-K., Asano, K., et al. (2003) · International Electron Devices Meeting 1999. Technical Digest (Cat. No.99CH36318) · doi:10.1109/iedm.1999.823848 · Cited by 371
X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O. (2014) · Scientific Reports · doi:10.1038/srep03857 · Cited by 357
Self-citationCellular-resolution connectomics: challenges of dense neural circuit reconstruction
Helmstaedter, M. (2013) · Nature Methods · doi:10.1038/nmeth.2476 · Cited by 313
PILATUS: A single photon counting pixel detector for X-ray applications
Henrich, B., Bergamaschi, A., Broennimann, C., Dinapoli, R., Eikenberry, E. F., Johnson, I., Kobas, M., Kraft, P., Mozzanica, A., & Schmitt, B. (2009) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2009.03.200 · Cited by 304
Self-citation
Cited by
High-resolution X-ray luminescence extension imaging
Ou, X., Qin, X., Huang, B., Zan, J., Wu, Q., Hong, Z., Xie, L., Bian, H., Yi, Z., Chen, X., et al. (2021) · Nature · doi:10.1038/s41586-021-03251-6 · Cited by 853
Zeng, M., Xiao, Y., Liu, J., Yang, K., & Fu, L. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00633 · Cited by 574
Metrology for the next generation of semiconductor devices
Orji, N. G., Badaroglu, M., Barnes, B. M., Beitia, C., Bunday, B. D., Celano, U., Kline, R. J., Neisser, M., Obeng, Y., & Vladar, A. E. (2018) · Nature Electronics · doi:10.1038/s41928-018-0150-9 · Cited by 501
In situ analytical techniques for battery interface analysis
Tripathi, A. M., Su, W.-N., & Hwang, B. J. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00180k · Cited by 488
Further improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Recent Development in X-Ray Imaging Technology: Future and Challenges
Ou, X., Chen, X., Xu, X., Xie, L., Chen, X., Hong, Z., Bai, H., Liu, X., Chen, Q., Li, L., et al. (2021) · Research · doi:10.34133/2021/9892152 · Cited by 351
Three-dimensional magnetization structures revealed with X-ray vector nanotomography
Donnelly, C., Guizar-Sicairos, M., Scagnoli, V., Gliga, S., Holler, M., Raabe, J., & Heyderman, L. J. (2017) · Nature · doi:10.1038/nature23006 · Cited by 335
Self-citationTwo-dimensional devices and integration towards the silicon lines
Wang, S., Liu, X., Xu, M., Liu, L., Yang, D., & Zhou, P. (2022) · Nature Materials · doi:10.1038/s41563-022-01383-2 · Cited by 332
In operando x-ray imaging of nanoscale devices: Composition, valence, and internal electrical fields
Johannes, A., Salomon, D., Martinez-Criado, G., Glaser, M., Lugstein, A., & Ronning, C. (2017) · Science Advances · doi:10.1126/sciadv.aao4044 · Cited by 49
Probing Organic Thin Films by Coherent X-ray Imaging and X-ray Scattering
Patil, N., Narayanan, T., Michels, L., Skjønsfjell, E. T. B., Guizar-Sicairos, M., Van den Brande, N., Claessens, R., Van Mele, B., & Breiby, D. W. (2019) · ACS Applied Polymer Materials · doi:10.1021/acsapm.9b00324 · Cited by 6
Self-citation
Metadata
- Authors
- Holler, M., Guizar-Sicairos, M., Tsai, E. H. R., Dinapoli, R., Müller, E., Bunk, O., Raabe, J., & Aeppli, G.
- Venue
- Nature
- Published
- 2017-03
- Volume
- 543
- Issue
- 7645
- Pages
- 402-406
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2595276417
- Cited by
- 497
- References
- 17
- FWCI
- 50.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.