The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
An electric-eel-inspired soft power source from stacked hydrogels
Open accessAbstract
Progress towards the integration of technology into living organisms requires electrical power sources that are biocompatible, mechanically flexible, and able to harness the chemical energy available inside biological systems. Conventional batteries were not designed with these criteria in mind. The electric organ of the knifefish Electrophorus electricus (commonly known as the electric eel) is, however, an example of an electrical power source that operates within biological constraints while featuring power characteristics that include peak potential differences of 600 volts and currents of 1 ampere. Here we introduce an electric-eel-inspired power concept that uses gradients of ions between miniature polyacrylamide hydrogel compartments bounded by a repeating sequence of cation- and anion-selective hydrogel membranes. The system uses a scalable stacking or folding geometry that generates 110 volts at open circuit or 27 milliwatts per square metre per gel cell upon simultaneous, self-registered mechanical contact activation of thousands of gel compartments in series while circumventing power dissipation before contact. Unlike typical batteries, these systems are soft, flexible, transparent, and potentially biocompatible. These characteristics suggest that artificial electric organs could be used to power next-generation implant materials such as pacemakers, implantable sensors, or prosthetic devices in hybrids of living and non-living systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836 · cited 3×
“calculated using Supplementary Equations (5) and (6).”
Ilievski, F., Mazzeo, A. D., Shepherd, R. F., Chen, X., & Whitesides, G. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201006464 · Cited by 1,381
Single-layer MoS2 nanopores as nanopower generators
Feng, J., Graf, M., Liu, K., Ovchinnikov, D., Dumcenco, D., Heiranian, M., Nandigana, V., Aluru, N. R., Kis, A., & Radenovic, A. (2016) · Nature · doi:10.1038/nature18593 · Cited by 1,239
Production of Electric Power by mixing Fresh and Salt Water in the Hydroelectric Pile
PATTLE, R. E. (1954) · Nature · doi:10.1038/174660a0 · Cited by 819
Lai, Y., Deng, J., Niu, S., Peng, W., Wu, C., Liu, R., Wen, Z., & Wang, Z. L. (2016) · Advanced Materials · doi:10.1002/adma.201603527 · Cited by 312
Ultralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285
Membrane potentials in the electroplates of the electric eel
Keynes, R. D., & Martins-Ferreira, H. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004849 · Cited by 243
Bennett, M. V. L. (1971) · Fish Physiology · doi:10.1016/s1546-5098(08)60051-5 · Cited by 230
Designing artificial cells to harness the biological ion concentration gradient
Xu, J., & Lavan, D. A. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.274 · Cited by 229
Microvalve-actuated precise control of individual droplets in microfluidic devices
Zeng, S., Li, B., Su, X., Qin, J., & Lin, B. (2009) · Lab on a Chip · doi:10.1039/b821803j · Cited by 214
Genomic basis for the convergent evolution of electric organs
Gallant, J. R., Traeger, L. L., Volkening, J. D., Moffett, H., Chen, P.-H., Novina, C. D., Phillips, G. N., Anand, R., Wells, G. B., Pinch, M., et al. (2014) · Science · doi:10.1126/science.1254432 · Cited by 206
Mansouri, K., Medeiros, F. A., Tafreshi, A., & Weinreb, R. N. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.2280 · Cited by 180
Additive manufacturing of hydrogel-based materials for next-generation implantable medical devices
Chin, S. Y., Poh, Y. C., Kohler, A.-C., Compton, J. T., Hsu, L. L., Lau, K. M., Kim, S., Lee, B. W., Lee, F. Y., & Sia, S. K. (2017) · Science Robotics · doi:10.1126/scirobotics.aah6451 · Cited by 172
A single-pixel wireless contact lens display
Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., et al. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/12/125014 · Cited by 148
Electrochemical Capacitors with High Output Voltages that Mimic Electric Eels
Sun, H., Fu, X., Xie, S., et al. (2016) · Advanced Materials · doi:10.1002/adma.201505742 · Cited by 136
Nakamura, Y., Nakajima, S., & Grundfest, H. (1965) · The Journal of General Physiology · doi:10.1085/jgp.49.2.321 · Cited by 125
Electrophorus electricus as a Model System for the Study of Membrane Excitability
Gotter, A. L., Kaetzel, M. A., & Dedman, J. R. (1998) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(97)00414-5 · Cited by 95
Synthetic Protocells to Mimic and Test Cell Function
Xu, J., Sigworth, F. J., & LaVan, D. A. (2009) · Advanced Materials · doi:10.1002/adma.200901945 · Cited by 76
Error in PubMed in: Global Burden of Visual Impairment and Blindness
Bourne, R., Price, H., Stevens, G., GBD Vision Loss Expert Group, & Battaglia Parodi, M. (2012) · Archives of Ophthalmology · doi:10.1001/jamaophthalmol.2013.1350 · Cited by 63
Shenkel, S., & Sigworth, F. J. (1991) · The Journal of General Physiology · doi:10.1085/jgp.97.5.1013 · Cited by 43
Young, C. J., Rozario, K., Serra, C. A., Poole-Warren, L. A., & Martens, P. J. (2013) · Biomicrofluidics · doi:10.1063/1.4816714 · Cited by 35
Cited by
Yang, C., & Suo, Z. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0018-7 · Cited by 1,709
A droplet-based electricity generator with high instantaneous power density
Xu, W., Zheng, H., Liu, Y., Zhou, X., Zhang, C., Song, Y., Deng, X., Leung, M., Yang, Z., Xu, R. X., et al. (2020) · Nature · doi:10.1038/s41586-020-1985-6 · Cited by 1,624
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Hydrogel Adhesion: A Supramolecular Synergy of Chemistry, Topology, and Mechanics
Yang, J., Bai, R., Chen, B., & Suo, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201901693 · Cited by 1,033
Self-citation
Metadata
- Authors
- Schroeder, T. B. H., Guha, A., Lamoureux, A., VanRenterghem, G., Sept, D., Shtein, M., Yang, J., & Mayer, M.
- Venue
- Nature
- Published
- 2017-12
- Volume
- 552
- Issue
- 7684
- Pages
- 214-218
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2773134645
- Cited by
- 590
- References
- 21
- FWCI
- 16.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.