Multi-platform assessment of transcriptome profiling using RNA-seq in the ABRF next-generation sequencing study
Open accessAbstract
High-throughput RNA sequencing (RNA-seq) greatly expands the potential for genomics discoveries, but the wide variety of platforms, protocols and performance capabilitites has created the need for comprehensive reference data. Here we describe the Association of Biomolecular Resource Facilities next-generation sequencing (ABRF-NGS) study on RNA-seq. We carried out replicate experiments across 15 laboratory sites using reference RNA standards to test four protocols (poly-A–selected, ribo-depleted, size-selected and degraded) on five sequencing platforms (Illumina HiSeq, Life Technologies PGM and Proton, Pacific Biosciences RS and Roche 454). The results show high intraplatform (Spearman rank R > 0.86) and inter-platform (R > 0.83) concordance for expression measures across the deep-count platforms, but highly variable efficiency and cost for splice junction and variant detection between all platforms. For intact RNA, gene expression profiles from rRNA-depletion and poly-A enrichment are similar. In addition, rRNA depletion enables effective analysis of degraded RNA samples. This study provides a broad foundation for cross-platform standardization, evaluation and improvement of RNA-seq.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 17 cited sources checked · 0 supported · 0 flagged
- Findingown data
Proton, PGM, and 454 detected more known junctions than Illumina HiSeq despite fewer bases sequenced.
“The Proton, PGM and 454 platforms detected more known junctions despite fewer bases sequenced compared to Illumina HiSeq.”
Quote in the paperSubstantial claim - Findingown data
Banding or altered coverage distributions were likely caused by use of a different library kit version at one test site.
“The data also showed “banding” or altered coverage distributions, likely caused by the use of a different library kit version at one of the test sites (C).”
Quote in the paperNot a substantial claim - Findingown data
In the same Illumina library, HiSeq detected 22.6 junctions/Mb and MiSeq detected 33.9 junctions/Mb.
“22.6 junctions/Mb for HiSeq vs. 33.9 junctions/Mb for MiSeq, Supplemental Fig. 26”
Quote in the paperNot a substantial claim - Findingown data
No platform had more than 51% of reads classified as putative duplicates.
“Yet, all platforms showed no more than 51% of reads as putative duplicates (Supplementary Fig. 24)”
Quote in the paperNot a substantial claim - Findingown data
Ribo-depleted RNA samples, whether degraded or not, consistently showed more uniform gene coverage than polyA-selected libraries.
“Notably, the ribo-depleted RNA samples, whether degraded or not, consistently showed more-uniform gene coverage than did polyA-selected libraries.”
Quote in the paperNot a substantial claim
- Findingown data
Efficiency and cost for splice junction and variant detection varied widely among all platforms.
“but highly variable efficiency and cost for splice junction and variant detection between all platforms”
Quote in the paperSubstantial claim - Findingown data
High read-depth platforms showed greater DEG overlap.
“Thus, although high read–depth platforms showed greater DEG overlap”
Quote in the paperNot a substantial claim - Findingown data
For all platforms, reported quality values were higher than empirically derived quality values based on sequence mismatches.
“Moreover, for all platforms, the reported QVs were higher than the empirically derived QVs based on sequence mismatches”
Quote in the paperNot a substantial claim - Findingown data
Inter-platform correlation of normalized transcript levels for samples A and B across different platforms was high, with an average R2 of 0.83.
“The inter-platform correlation was high (R2 average of 0.83) for the same samples profiled on different platforms”
Quote in the paperSubstantial claim - Findingown data
Uniformity of coverage across exons is improved with long-read technology such as PacBio despite less read depth.
“However, uniformity of coverage across exons is improved with long-read technology such as PacBio (Fig. 4a and Supplementary Table 3), despite less read depth.”
Quote in the paperSubstantial claim - Findingown data
Almost all samples showed a fairly similar distribution of gene coverage.
“Almost all samples showed a fairly similar distribution of coverage for genes (Fig. 2).”
Quote in the paperNot a substantial claim - Findingown data
Splice junction profiling showed an early plateau for detection of known junctions.
“Splice junction profiling showed an early plateau for detection of known junctions (Fig. 3e).”
Quote in the paperSubstantial claim - Findingown data
454 and PacBio had the fewest putative duplicates, at 12-20%.
“with the 454 and PacBio platforms showing the fewest duplicates (12–20%).”
Quote in the paperNot a substantial claim- Rests on an assumption: PacBio library construction does not include amplification of the final cDNA library.
- Findingown data
The highest and most uniform coverage of full-length transcripts came from combining 3' polyA and 5'G cap enrichment with long-read PacBio technology.
“Finally, the highest and most-uniform coverage of full-length transcripts came from preparing samples with enrichment for both the 3′ polyA tail and an antibody (Ab) for the 5′ methylguanylate cap (5′G cap), combined with long-read technology (see Online Methods for Pacific Biosciences).”
Quote in the paperSubstantial claim - Findingown data
Across the deep-count sequencing platforms, expression measures showed high concordance both within and between platforms.
“The results show high intra-platform and inter-platform concordance for expression measures across the deep-count platforms”
Quote in the paperSubstantial claim - Findingown data
Universal STAR alignments had the lowest mapping error rate.
“since these alignments always showed the lowest mapping error rate”
Quote in the paperSubstantial claim - Findingown data
Quality values across platforms ranged from Q10 to Q60.
“Results ranged from Q10 (90% accuracy) to Q60 (99.9999% accuracy) across platforms”
Quote in the paperNot a substantial claim - Findingown data
HiSeq showed the lowest median inter-site CV.
“with HiSeq showing the lowest median CV.”
Quote in the paperNot a substantial claim - Findingown data
Platforms showed a median inter-site CV of 11-39% for quantification of detected genes using normalized expression values.
“The platforms showed a median range of 11–39% inter-site CV (Coefficient of Variation) in their quantification of detected genes using normalized gene expression values”
Quote in the paperSubstantial claim - Findingown data
Intra-platform correlation was even higher, with an average R2 greater than 0.86.
“and the intra-platform correlation was even higher (R2 average greater than 0.86).”
Quote in the paperSubstantial claim - Findingown data
Unannotated junctions had lower concordance across platforms than known junctions.
“However, unannotated junctions have lower concordance than known junctions across platforms (Fig. 3g).”
Quote in the paperSubstantial claim - Findingown data
Across platforms, substitution mismatch rates ranged from 0.6% to 7.1%.
“but the range between all platforms spanned 0.6–7.1%.”
Quote in the paperNot a substantial claim - Findingcitation
Most platforms showed a biased quality-value distribution in the first 1-16 bases, attributable to reverse transcriptase priming.
“First, most platforms show a biased QV distribution in the first 1–16 bases, a known effect from the reverse transcriptase (RT) priming step32.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [32] Dobin, A. et al. STAR: ultrafast universal RNA-seq aligner. Bioinformatics 29, 15–21 (2013). source
Not checked in the free run.
- Findingown data
For HiSeq, single-base substitutions were the most common mismatch type.
“The most common type of mismatch for HiSeq was single-base substitutions”
Quote in the paperNot a substantial claim - Findingown data
Except for ELAND, platform-specific aligners produced better mapping rates, gene-body coverage evenness, and PrimePCR correlations than STAR applied uniformly.
“With the exception of ELAND, each platform-specific algorithm produced better mapping rates, gene-body coverage evenness and Spearman correlations with PrimePCR quantification (Supplementary Tables 2–4) when compared to STAR applied uniformly across all platforms.”
Quote in the paperSubstantial claim - Findingown data
Indel mismatch rates varied widely across platforms, from 0.017% to 4.4% of all mismatches.
“Insertion/deletion (indel) type mismatch rates were also highly variable between platforms, spanning 0.017–4.4% of all mismatches observed.”
Quote in the paperNot a substantial claim - Findingown data
Cross-platform splicing data showed that read types dramatically influenced each platform's measure of low abundance transcripts.
“These cross-platform splicing data showed that the types of reads dramatically influenced each platform’s measure of low abundance transcripts.”
Quote in the paperSubstantial claim - Findingown data
The ABRF-NGS Study's results include more than one million putative novel splice junctions observed in at least one platform.
“The ABRF-NGS Study’s results include a wealth of putative novel splice junctions, with more than one million such junctions observed in at least one platform (Gene Expression Omnibus GSE46876)”
Quote in the paperSubstantial claim - Findingown data
The resulting data sets nearly double the catalog of splice junctions for these RNA standard samples.
“The resulting data sets nearly double the catalog of splice junctions for these RNA standard samples”
Quote in the paperSubstantial claim - Findingown data
ERCC correlation to TaqMan on the PGM platform was similar to that on other platforms, with mean R2 of 0.78.
“these ranges of correlation to TaqMan were similar to that observed for ERCCs sequenced on the PGM, where the mean R2 = 0.78”
Quote in the paperNot a substantial claim - Findingown data
The dual enrichment method for PacBio libraries provided superior 5′ to 3′ coverage of sequenced transcripts.
“The dual enrichment method for PacBio libraries provided superior 5′ to 3′ coverage of the sequenced transcripts, as illustrated by comparisons across platforms for genes consistently detected by PacBio (Supplementary Fig. 37)”
Quote in the paperNot a substantial claim - Findingown data
Ribo-depleted libraries had 40-47% of bases mapping to introns, compared with 7-12% for polyA RNA from the same sample.
“The ribo-depleted libraries showed 40–47% of the bases mapping to introns vs. 7–12% for polyA RNA from the same sample”
Quote in the paperSubstantial claim - Findingown data
Both polyA and ribo-depletion methods produced fairly consistent RNA abundance measures (FPKM), with a median FPKM difference of only 0.055 between all genes.
“Both methods produced fairly consistent measures of RNA abundance (FPKM, Online Methods), with a median FPKM difference of only 0.055 between all genes.”
Quote in the paperSubstantial claim - Findingown data
Surrogate variable analysis enabled removal of latent variables from data for ribo-depleted and polyA-enriched libraries, producing nearly indistinguishable lists of DEGs.
“surrogate variable analysis enabled removal of latent variables from the data for ribo-depleted and polyA-enriched libraries, producing nearly indistinguishable lists of DEGs”
Quote in the paperSubstantial claim - Findingown data
Each platform produced unique subsets of statistically significant DEGs (FDR<0.05, FC>2), accounting for 6-11% of all called DEGs detected uniquely by a platform or preparation method.
“each platform produced unique subsets (from unique systematic effects) of statistically significant DEGs (FDR < 0.05, fold change > 2, Online Methods), ranging from 6–11% of all called DEGs detected uniquely by a platform or preparation method”
Quote in the paperSubstantial claim - Findingown data
Degraded RNA analysis was highly correlated (Pearson R2 >0.83) to corresponding intact samples in PrimePCR comparison.
“a comparison to the orthogonal PrimePCR dataset showed that the degraded RNA analysis was highly correlated (Pearson R2 >0.83) to the corresponding intact samples”
Quote in the paperSubstantial claim - Findingown data
Few overall differences were observed between polyA and ribo-depleted preparations in gene quantification and DEG detection.
“Yet, few overall differences were observed between the polyA and ribo-depleted library preparations in gene quantification and detection of differentially expressed genes.”
Quote in the paperSubstantial claim - Findingown data
Both library types had similar accuracy as measured by Matthews correlation coefficient when compared to 802 TaqMan assays.
“Both library types had similar accuracy as measured by Matthews correlation coefficient (MCC, Fig. 5d)40, 41, which is a joint measure of the assay’s sensitivity and specificity.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [40] Cui, P. et al. A comparison between ribo-minus RNA-sequencing and polyA-selected RNA-sequencing. Genomics 96, 259–265 (2010). source
Not checked in the free run.
- cites [41] Leek, J.T., Johnson, W.E., Parker, H.S., Jaffe, A.E. & Storey, J.D. The sva package for removing batch effects and other unwanted variation in high-throughput experiments. Bioinformatics 28, 882–883 (2012). source
Not checked in the free run.
- Findingown data
Comparisons of platform-specific aligners with STAR showed that mapping rates, error rates and transcript coverage are larger concerns than gene quantification for inter-platform data.
“Comparisons of platform-specific aligners with STAR showed that mapping rates, error rates and transcript coverage are larger concerns when considering inter-platform data than is gene quantification”
Quote in the paperSubstantial claim - Findingown data
Degraded RNA after ribo-depletion had more reads mapping to intronic areas, similar to ribo-depleted libraries from intact RNA.
“similar to ribo-depleted libraries from intact RNA, more reads mapped to intronic areas of the genome”
Quote in the paperNot a substantial claim - Findingown data
Comparison of gene expression quantification across intra-platform, inter-platform, inter-protocol and inter-aligner comparisons demonstrated high correlations overall.
“comparison of gene expression quantification, including results from intra-platform, inter-platform, inter-protocol and even inter-aligner comparisons, demonstrated high correlations overall”
Quote in the paperSubstantial claim - Findingown data
Lower intronic reads were similarly observed for polyA RNA on other platforms.
“lower intronic reads were similarly observed for polyA RNA on the other platforms, Supplementary Fig. 32”
Quote in the paperNot a substantial claim - Findingown data
Comparison of polyA and ribo-depleted libraries showed different detection of nonpolyadenylated transcripts, 3′UTRs and introns.
“A comparison of polyA and ribo-depleted libraries showed different detection of nonpolyadenylated transcripts, 3′UTRs and introns”
Quote in the paperSubstantial claim - Findingown data
Putative novel splice junctions displayed greater inter-platform disparity than known splice junctions.
“These putative novel splice junctions displayed greater inter-platform disparity than the known splice junctions (Fig. 3e)”
Quote in the paperSubstantial claim - Findingown data
Sequencing of degraded RNA after ribo-depletion fully covered gene bodies.
“sequencing of the degraded RNA, after ribo-depletion, fully covered the gene bodies (Fig. 2)”
Quote in the paperSubstantial claim - Findingown data
Gene quantification from polyA-enriched and ribo-depleted libraries was similar.
“As polyA and ribo-depleted gene quantifications were similar”
- Also stated in: § Discussion · boosted
“results from polyA-enriched and ribo-depleted RNA libraries, and even libraries made from severely degraded RNAs, are comparable”
Quote in the paperSubstantial claim - Also stated in: § Discussion · boosted
- Findingown data
The ribo-depletion library method produced a read source distribution very different from polyA preparation.
“The ribo-depletion library method produced a read source distribution very different from the polyA preparation method (Fig. 5a).”
Quote in the paperNot a substantial claim - Findingown data
ERCC synthetic RNA controls correlated better with TaqMan in ribo-depleted libraries than in polyA-enriched libraries, with mean R2 of 0.91 and 0.82 respectively.
“the synthetic RNAs spiked into these samples (ERCC controls) performed slightly better in the ribo-depletion protocol than the polyA-enrichment protocol (mean R2 = 0.91 and 0.82, respectively)”
- Also stated in: § Discussion · plain
“these standards performed better in ribo-depleted libraries than in polyA libraries”
Quote in the paperNot a substantial claim - Also stated in: § Discussion · plain
- Findingown data
Degraded RNA had lower Spearman rank-order correlation with quantitative PCR for expression differences between samples A and B.
“the degraded RNA did have a lower Spearman rank-order correlation with quantitative PCR for the expression differences detected between samples A and B”
Quote in the paperNot a substantial claim - Findingown data
DEGs without SVA analysis show similar but slightly lower overlap percentage and MCC.
“The corresponding DEGs without SVA analysis show similar but slightly lower overlap percentage and MCC (Supplementary Fig. 33).”
Quote in the paperNot a substantial claim - Findingown data
Pairwise comparison of average normalized gene expression across replicates of the two library types for four standard samples showed high Spearman correlations (A: 0.91, B: 0.93, C: 0.92, D: 0.93).
“A pairwise comparison of the average normalized gene expression across replicates of the two library types for the four standard samples showed high Spearman correlation coefficients (sample A: 0.91, B: 0.93, C: 0.92, D: 0.93).”
Quote in the paperSubstantial claim - Findingown data
Overall numbers of DEGs detected between biologically distinct samples were consistent between library preparation methods.
“The overall numbers of DEGs detected between the biologically distinct samples (A vs. B, A vs. D, etc.) were also consistent between library preparation methods”
Quote in the paperSubstantial claim - Premisenone given
Only two inter-site RNA-seq variation studies are publicly available: MAQC-III/SEQC and GEUVADIS.
“Only two inter-site variation studies are publicly available: the MAQC-III (a.k.a. the Sequencing Quality Control Consortium, SEQC)11 study and the GEUVARDIS Consortium12.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [11] SEQC/MAQC-III Consortium. A comprehensive assessment of RNA-seq accuracy, reproducibility and information content by the Sequencing Quality Control Consortium. Nat. Biotechnol. 10.1038/nbt.2957 (24 August 2014).
Not checked in the free run.
- cites [12] 't Hoen, P.A. et al. Reproducibility of high-throughput mRNA and small RNA sequencing across laboratories. Nat. Biotechnol. 31, 1015–1022 (2013). source
Not checked in the free run.
- Premisereasoning
Very little data exist on cross-site variation of expression measures for high-throughput sequencing platforms.
“For high-throughput sequencing platforms, however, very little data exist about cross-site variation of expression measures.”
Quote in the paperSubstantial claim - Premisereasoning
Important RNA profiling parameters such as differential expression and splice variant detection have not been consistently evaluated.
“Moreover, important RNA profiling parameters such as differential expression and splice variant detection have not been consistently evaluated.”
Quote in the paperSubstantial claim - Interpretationreasoning
Reduced duplication with 454 is likely because amplification occurs after template attachment to single beads, so individual molecules have less chance to spawn multiple reads.
“while the reduced duplication with 454 is likely because the amplification step takes place after template attachment to single beads, so individual molecules in the library have less chance to spawn multiple reads.”
Quote in the paperNot a substantial claim- Rests on an assumption: In 454 library construction, amplification occurs after template attachment to single beads.
- Premisecitation
Reverse transcriptase bias can affect observed GC content and base-frequency data.
“This RT bias can also affect the observed GC content (Supplementary Figs. 7–11) and base-frequency data11,33, 34”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [11] SEQC/MAQC-III Consortium. A comprehensive assessment of RNA-seq accuracy, reproducibility and information content by the Sequencing Quality Control Consortium. Nat. Biotechnol. 10.1038/nbt.2957 (24 August 2014).
Not checked in the free run.
- cites [33] Hansen, K.D., Brenner, S.E. & Dudoit, S. Biases in Illumina transcriptome sequencing caused by random hexamer priming. Nucleic Acids Res. 38, e131 (2010). source
Not checked in the free run.
- cites [34] Aird, D. et al. Analyzing and minimizing PCR amplification bias in Illumina sequencing libraries. Genome Biol. 12, R18 (2011). source
Not checked in the free run.
- Premisenone given
No other study has used five platforms and two standardized RNA samples replicated at multiple sites.
“no other study has been conducted using five platforms and two standardized RNA samples replicated at multiple sites”
Quote in the paperSubstantial claim - Premisecitation
RNA-seq is expected to produce some reads from highly expressed transcripts that begin at the same nucleotide and are designated duplicates.
“RNA-seq is expected to produce some reads from highly expressed transcripts that begin at the same nucleotide and are thus designated “duplicate.””
Quote in the paperSubstantial claim0 of 2 sources checked- cites [8] Quail, M.A. et al. A tale of three next generation sequencing platforms: comparison of Ion Torrent, Pacific Biosciences and Illumina MiSeq sequencers. BMC Genomics 13, 341 (2012). source
Not checked in the free run.
- cites [33] Hansen, K.D., Brenner, S.E. & Dudoit, S. Biases in Illumina transcriptome sequencing caused by random hexamer priming. Nucleic Acids Res. 38, e131 (2010). source
Not checked in the free run.
- Interpretationown data
Rare-isoform quantification benefits most from greater read depths, as apparent for SRP9.
“This effect was apparent for RNA splice isoforms such as SRP9 (Fig. 4a), suggesting that rare-isoform quantification benefits the most from greater read depths (such as from the Illumina HiSeq and Life Technologies Proton).”
Quote in the paperSubstantial claim - Study design and conductnone given
For platforms other than 454 and PacBio, the analysis cannot distinguish whether observed duplicates come from independent transcripts or from library amplification.
“For the other platforms, this analysis cannot distinguish whether observed duplicates are due to independent transcripts or are a consequence of library amplification”
Quote in the paperNot a substantial claim - Premisecitation
Prior microarray platform comparisons found high inter-platform concordance for detecting differentially expressed genes.
“prior work comparing microarray platforms and methods showed high levels of inter-platform concordance for the ability to detect differentially expressed genes.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [10] Shi, L. et al. The MicroArray Quality Control (MAQC) project shows inter- and intraplatform reproducibility of gene expression measurements. Nat. Biotechnol. 24, 1151–1161 (2006). source
Not checked in the free run.
- Interpretationown data
A substantial number of previously unannotated predicted junctions are likely genuine, as they were observed using multiple platforms.
“However, a substantial number of the previously unannotated, predicted junctions are likely genuine, as they were observed using multiple platforms”
Quote in the paperSubstantial claim - Interpretationown data
Degraded RNA, after ribo-depletion, performed as well as intact RNA libraries across multiple metrics.
“Multiple metrics indicated that the degraded RNA performed as well as the polyA-enriched or ribo-depleted libraries from intact RNA.”
- Also stated in: § Discussion · boosted
“gene detection and quantification with highly fragmented or degraded RNA samples (from three types of degradation) is strikingly similar to intact RNA, once ribosomal RNA is removed”
Quote in the paperSubstantial claim - Also stated in: § Discussion · boosted
- Interpretationown data
Appropriate library preparation of degraded RNA can produce accurate expression measurements.
“These data indicate that although appropriate library preparation of degraded RNA can produce accurate expression measurements”
Quote in the paperSubstantial claim - Interpretationown data
Despite overall similarities, distinct transcriptomes are represented in libraries prepared by polyA enrichment, ribo-depletion or combined polyA and 5′G cap enrichment.
“However, despite their overall similarities, distinct transcriptomes are represented in libraries prepared by polyA enrichment, ribo-depletion or combined polyA and 5′G cap enrichment”
Quote in the paperSubstantial claim - Interpretationreasoning
Different alignment algorithms have different influences on comparisons between experiments depending on the metric studied.
“the use of different alignment algorithms will have different influences on comparisons between experiments depending on the metric studied”
Quote in the paperSubstantial claim - Interpretationreasoning
RNA-seq of total RNA will require greater read depths for ribo-depleted libraries (~2.5X) than for polyA libraries to achieve equal coverage of exons, owing to higher rate of intron-mapped reads.
“Owing to the higher rate of intron-mapped reads, RNA-seq of total RNA will require greater read depths for ribo-depleted libraries (~2.5X) than for polyA libraries to achieve equal coverage of exons”
Quote in the paperNot a substantial claim - Interpretationcitation
Similar degraded RNA results were recently reported, suggesting low quality samples can now be considered for reliable RNA-seq expression profiling.
“Similar degraded RNA results were recently reported26, suggesting that low quality samples can now be considered for reliable RNA-seq expression profiling”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [26] Pareek, C.S., Smoczynski, R. & Tretyn, A. Sequencing technologies and genome sequencing. J. Appl. Genet. 52, 413–435 (2011). source
Not checked in the free run.
- Interpretationcitation
This should support studies using old, degraded or fragmented RNAs, such as FFPE tissues.
“This should support studies using old, degraded or fragmented RNAs, such as those from formalin-fixed, paraffin-embedded (FFPE) tissues in clinical archives”
Quote in the paperSubstantial claim - Interpretationreasoning
The different detection of nonpolyadenylated transcripts is an intentional consequence of the enrichment protocol.
“The former is an intentional consequence of the enrichment protocol”
Quote in the paperNot a substantial claim - Interpretationreasoning
The instruments span different chemistries, measurement techniques, and base-calling methods, which likely contribute to system-specific noise profiles.
“These instruments span different chemistries, measurement techniques (optical vs. electrical) and base-calling methods, all of which likely play roles in the system-specific noise profiles”
Quote in the paperSubstantial claim - Interpretationown data
Broader inter-study analyses and data mining can be successfully carried out across multiple platforms despite intrinsic differences between technologies, methods and aligners.
“This result suggests broader inter-study analyses and data mining can be successfully carried out across multiple platforms despite intrinsic differences between technologies, methods and aligners”
Quote in the paperSubstantial claim - Interpretationreasoning
Bioinformatics noise can be placed alongside technical and biological noise as key factors in experimental design.
“the importance of ‘bioinformatics noise’ can be placed alongside technical and biological noise as key factors in experimental design”
Quote in the paperNot a substantial claim - Interpretationown data
Given sufficient depth, ribo-depleted libraries can include almost all differentially detected genes identified by polyA preparation, without loss of sensitivity or specificity.
“Given sufficient depth of sequencing, results from ribo-depleted libraries can include almost all of the differentially detected genes identified by the polyA preparation method, without loss of sensitivity or specificity”
Quote in the paperSubstantial claim
- May combine two claims. 35
- Classified as probably not a substantial claim. 4
May combine two claims.
Findingown dataThere is a clear log-linear relationship between sequence base depth and gene detection, so increasing sequencing depth finds more genes.
“A clear log-linear relationship was observed between sequence base depth and gene detection (Fig. 3d), showing that increasing the depth of sequencing for any platform is a quick means to find more genes.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataFor most platforms, read ends contain most noise, and lower quality values also occur at read beginnings.
“Thus, for most platforms, the ends of the reads are where most “noise” was observed, but lower QVs also occurred at the beginnings of the reads.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataIn size-selected PacBio CCS libraries, polyA+5'G cap enrichment captured full-length expressed transcripts, with 90% showing complete transcript sequences in the 1-2 kb range or longer.
“An examination of the size-selected PacBio CCS libraries demonstrated that the polyA+5’G cap enrichment method captured the full lengths of expressed transcripts (Supplementary Fig. 28), with the majority (90%) showing complete transcript sequences in the 1–2 kb range or even longer.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataKnown GENCODE junctions showed higher inter-platform agreement, with most detected by three or more platforms.
“The known GENCODE junctions (v12) showed higher inter-platform agreement, with most of these junctions detected by three or more platforms”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataA tradeoff can occur between higher mapping rate and accuracy; TMAP/GSRM had a higher mapping rate than STAR but a higher empirical error rate.
“These data showed that a tradeoff between higher mapping rate and accuracy can occur for RNA-seq, such as the increased mapping rate with TMAP/GSRM vs. STAR (Supplemental Table 2) that led to a higher empirically derived error rate (Fig. 1b).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataSimilar quality-value profiles were observed for samples A and B and across different RNA size fractions.
“Second, similar QV profiles were observed for samples A and B, and across different RNA size fractions.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataRibosomal RNA depletion allowed effective analysis of degraded RNA samples and could be compared with polyA-enriched fractions.
“These data also demonstrate that ribosomal RNA depletion can both enable effective analysis of degraded RNA samples and be readily compared to polyA-enriched fractions.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataThe ratio of junctions detected per megabase varied widely, but longer reads were more efficient at capturing junctions.
“The ratio of the number of junctions detected as a function of total bases sequenced (junctions/Mb) revealed a wide range of values (Fig. 3f) but clearly demonstrated that longer reads are a more efficient way to capture junctions.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataRead length distributions differed by platform: Gaussian for 454, ski-jump for Proton and PGM, and uniform for Illumina.
“The read length distributions revealed distinct types for variable-read platforms, including Gaussian (454) and “ski-jump” (Proton and PGM), and the expected uniform lengths for Illumina platforms.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataThe largest increase in quality values came from PacBio circular consensus sequencing, with median QVs near 40 and wide variation.
“the largest increase in QVs came from the circular consensus sequencing (CCS) for the PacBio data (Supplementary Fig. 2), where median QVs near 40 were observed, though with a wide range of variation.”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataSpearman correlations of log2 fold differences between each platform and PrimePCR ranged from 0.83 to 0.89, ranked 454 < PGM < Proton, HiSeq.
“the Spearman correlations of the log2 fold differences were ranked as 454 < PGM < Proton, HiSeq, ranging from 0.83 to 0.89.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataA majority of DEGs were observed by two or more methods, but each method produced unique DEGs at all statistical significance and fold-change cutoffs.
“Although a majority of DEGs were observed by two or more methods, each produced unique DEGs at all statistical significance and fold-change cutoffs”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataHigh intra-platform consistency (R2>0.86) and high inter-platform concordance (R2>0.83) measured by Spearman rank correlation using normalized gene expression.
“Using normalized gene expression as a comparison measure, we found high intra-platform consistency (R2>0.86) and high inter-platform concordance (R2> 0.83) measured by Spearman rank correlation (Fig. 3b)”
Quote in the paperSubstantial claimMay combine two claims.
FindingreasoningLong-read sequencing effectively cataloged splicing isoforms, but had less dynamic range for transcript quantitation and discovery due to lower read depths.
“Long-read sequencing effectively cataloged splicing isoforms, but had less dynamic range for transcript quantitation and discovery due to lower read depths”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataDegraded RNA showed minor differences in gene detection or DEG accuracy, with high Spearman correlation (R2 >0.96) to intact RNA.
“the degraded RNA showed minor differences in gene detection or DEG accuracy, with high Spearman correlation (R2 >0.96, Fig. 3c) in expression comparisons to intact RNA samples”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataSpearman correlation with qPCR for DEGs was highest for heat degradation (R2=0.83), then RNase A (0.79), then sonication (0.74).
“The Spearman correlation was highest for heat degradation (R2 = 0.83, AH), followed by RNase A (R2= 0.79, AR), and then sonication (R2=0.74, AS)”
Quote in the paperSubstantial claimMay combine two claims.
Findingnone givenThe revised Illumina library kit (v2 vs v3) includes built-in ribo-depletion and tags cDNA strand orientation, and the two protocols produced differences in gene-body coverage.
“The revised version of the Illumina library kit (v2 vs. v3) includes built-in ribo-depletion and tags cDNA strand orientation, and the two protocols produced differences in gene-body coverage”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataA near-complete reconstruction of transcriptome profile was observed when using degraded RNA in ribo-depletion protocol, with some variation between degradation treatments.
“a near-complete reconstruction of the transcriptome profile was observed when using degraded RNA in the ribo-depletion protocol, with some variation between degradation treatments, as judged by correlations to the expression abundances measured in intact samples A and B by quantitative PCR and by the uniform coverage of full transcript lengths”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataRibo-depleted libraries were enriched for non-coding RNAs such as lncRNAs and snoRNAs, whereas polyA libraries were enriched for protein-coding and mitochondrial genes.
“As expected, the ribo-depleted libraries were enriched for non-coding RNAs, such as lncRNAs and snoRNAs (Supplementary Table 6), whereas the polyA libraries were enriched for protein-coding genes and mitochondrial genes (Supplementary Tables 6–8)39.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [39] Smyth, G.K. in Bioinformatics and Computational Biology Solutions Using R and Bioconductor (eds. Gentleman, R., Carey, V., Huber, W., Irizarry, R. & Dudoit, S.) 397–420 (Springer New York, 2005).
Not checked in the free run.
May combine two claims.
Findingown dataThis study found similar RNA-seq results between various NGS platforms and similar ranges in coefficients of variance across lab sites for each platform.
“This study found similar RNA-seq results between the various NGS platforms and similar ranges in coefficients of variance across lab sites for each platform”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataMore genes with lower expression were observed with ribo-depletion, whereas polyA libraries contained more highly expressed genes and 3' UTRs.
“However, more genes with lower levels of expression were observed with the ribo-depletion method, whereas the polyA libraries contained more highly expressed genes and 3′ untranslated regions (3′ UTR) Supplementary Fig. 33).”
Quote in the paperNot a substantial claimMay combine two claims.
Findingown dataPercentage of shared DEGs ranges from 67-81% at FDR < 0.01 and fold-change > 2, and similarly 68-81% after SVA.
“Also, the percentage of shared DEGs ranges from 67– 81% at FDR < 0.01 and fold-change > 2, and similarly ranges from 68–81% after SVA.”
Quote in the paperSubstantial claimMay combine two claims.
Findingown dataMedian MCC was 0.659 before SVA and 0.678 after SVA, with an average increase of 0.015.
“The median MCC is 0.659 before SVA and 0.678 after SVA, with an average increase of 0.015.”
Quote in the paperNot a substantial claimMay combine two claims.
PremisecitationThose prior inter-site studies were limited to one platform or did not assess newer widely used RNA-seq methods.
“These studies were either limited to one platform or did not assess some newer RNA-seq methods that are now widely used.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [11] SEQC/MAQC-III Consortium. A comprehensive assessment of RNA-seq accuracy, reproducibility and information content by the Sequencing Quality Control Consortium. Nat. Biotechnol. 10.1038/nbt.2957 (24 August 2014).
Not checked in the free run.
- cites [12] 't Hoen, P.A. et al. Reproducibility of high-throughput mRNA and small RNA sequencing across laboratories. Nat. Biotechnol. 31, 1015–1022 (2013). source
Not checked in the free run.
May combine two claims.
Interpretationown dataCombining appropriate sample preparation and long reads can create cDNA profiles approaching full-length mRNA sequences from complex samples, underlining utility of long-read platforms despite lower read depths.
“These results indicate that a combination of appropriate sample preparation and long reads can readily create cDNA profiles that approach the full-length sequences of mRNAs from complex samples, underlining the utility of long read platforms, despite the lower read depths they may produce37.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [37] McKenna, A. et al. The Genome Analysis Toolkit: a MapReduce framework for analyzing next-generation DNA sequencing data. Genome Res. 20, 1297–1303 (2010). source
Not checked in the free run.
May combine two claims.
Interpretationown dataA follow-up long-read Illumina MiSeq experiment showed a similar boost in junction identification, suggesting splice junction detection is most affected by read length rather than library preparation or sequencing chemistry.
“However, a follow-up experiment with long-read Illumina MiSeq data (2×250 bp paired-end reads) showed a similar boost in junction identification (Supplementary Fig. 26), suggesting that splice junction detection is most affected by read length, rather than library preparation or sequencing chemistry.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataGene coverage can be affected by platform and preparation-dependent factors, and aligners can also play a role.
“This indicates that gene coverage can be affected by platform and preparation-dependent factors, but aligners can also play a role (Supplementary Table 3).”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
PremisecitationThe MAQC study found similar coefficients of variation between microarray platforms.
“The Microarray Quality Control (MAQC) Consortium landmark study10 examined the degree of variance within and across many different microarray platforms and found similar coefficients of variation between platforms.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [10] Shi, L. et al. The MicroArray Quality Control (MAQC) project shows inter- and intraplatform reproducibility of gene expression measurements. Nat. Biotechnol. 24, 1151–1161 (2006). source
Not checked in the free run.
Classified as probably not a substantial claim.
Premisenone givenNo gold standard reference data exist on the dynamic range of differential expression and splicing that includes different sample preparation protocols, instruments, and analysis strategies.
“but there is no “gold standard” of reference data on the dynamic range of differential expression and splicing that includes different sample preparation protocols, instruments and data analysis strategies.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataLower detection agreement for rare isoforms is likely due to lower expression levels, but they may also represent platform-specific artifacts.
“An examination of these rare isoforms revealed that the lower detection agreement is likely due to their lower expression levels (Supplementary Fig. 27), but they also may represent platform-specific artifacts.”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataBoth long- and short-read technologies measure gene expression with similar levels of statistical variation, but show a ten-fold variation for error rates in indels.
“These results indicate that both long- and short-read technologies measure gene expression with similar levels of statistical variation, although they show a ten-fold variation for error rates in indels”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningThe greater disparity of novel splice junctions was likely due to challenge of correctly predicting novel isoforms and possibly high false-positive rate expected from lower expression levels.
“This difference was likely due to the challenge of correctly predicting novel isoforms and also to the possibly high false-positive rate of such predictions, which is expected given their lower expression levels”
Quote in the paperSubstantial claimProbably not a substantial claim: may not pass S2 (checkable).
Interpretationown dataSurrogate variable analysis is a powerful and strongly recommended method for ameliorating effects of inter-batch and cross-protocol noise.
“illustrating the utility of surrogate variable analysis as a powerful and strongly recommended method for ameliorating the effects of inter-batch and cross-protocol noise”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Interpretationnone givenTranscriptome measurement variations between reference datasets are easily avoided by consistently using the same protocols, platform, and analysis pipeline for all samples in an experiment.
“Transcriptome measurement variations demonstrated between the reference datasets are easily avoided by consistently using the same protocols, platform, and analysis pipeline for all samples in an experiment”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown dataDeeper sequencing is needed to reveal low abundance transcripts and splice junctions; read depth should be key when goals include rarely expressed genes, introns, non-polyadenylated targets.
“the results clearly show that deeper sequencing of the transcriptome is needed to reveal low abundance transcripts and splice junctions, indicating that read depth should be a key consideration when experimental goals include rarely expressed genes, coverage of introns and non-polyadenylated targets”
Quote in the paperSubstantial claimMay combine two claims.
InterpretationreasoningVery deep sampling is not currently cost-effective with long-read platforms such as PacBio or 454, so shorter read platforms are currently best discovery platforms for low-abundance targets.
“Very deep sampling is not currently cost-effective with long-read platforms such as PacBio or 454 (Table 1), and thus the best discovery platforms for low-abundance targets are currently the shorter read platforms, as they can cover wider dynamic range of RNA molecules (i.e., generate more reads per sample)”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataThe reported QV values of all platforms are higher than empirically derived error rates, indicating that a splicing-aware, base quality score recalibration may be needed for RNA-seq.
“The reported QV values of all platforms are all higher than empirically derived error rates, indicating that a splicing-aware, base quality score recalibration may be needed for RNA-seq, as is already done for DNA-seq with GATK”
Quote in the paperNot a substantial claimMay combine two claims.
Interpretationown dataLonger read NGS technologies have the best ability to efficiently catch the vast majority of known splice junctions, indicating they can be effective for annotating splicing complexity.
“Despite lower read depths and higher costs, the longer read NGS technologies have the best ability to efficiently catch the vast majority of known splice junctions (Fig. 3d–g), indicating that they can be an effective means to annotate splicing complexity”
Quote in the paperSubstantial claimMay combine two claims.
Interpretationown dataClinical molecular diagnostics that rely on nucleic acid biomarkers will require technical stability across time and within and between studies, which this study helps to establish.
“These and other applications, especially clinical molecular diagnostics that rely on nucleic acid biomarkers, will require a level of technical stability across time and both within and between studies, which this study helps to establish”
Quote in the paperNot a substantial claim
The paper relies on this without support.
The RNA reference samples and their mixtures are suitable standards for benchmarking RNA-seq platforms and protocols.
“Detection of differential RNA abundance was evaluated using two commercially available and very distinct RNA samples: A = RNA from cancer cell lines; B = RNA from pooled normal human brain tissues; and two pre-defined mixtures of these samples (C = [75% A + 25% B]; D = [25% A + 75% B]).”
The paper relies on this without support.
The PrimePCR and TaqMan RT-qPCR measurements provide a valid orthogonal benchmark for RNA-seq accuracy and dynamic range.
“we leveraged a data set of 18,124 PrimePCR reactions and used it with 802 previously published10 TaqMan RT-qPCR reactions as orthogonal measurements to gauge the linear response and dynamic range of the RNA-seq results from the different platforms and protocols.”
The paper relies on this without support.
Unannotated splice junctions detected on at least three platforms are sufficiently reliable to be reported as novel junctions.
“Therefore, only unannotated splice junctions observed on at least three platforms (which still includes >20,000 junctions per sample) are reported in this analysis.”
The paper relies on this without support.
PacBio library construction does not include amplification of the final cDNA library.
“PacBio library construction does not include any amplification step of the final cDNA library”
The paper relies on this without support.
In 454 library construction, amplification occurs after template attachment to single beads.
“the amplification step takes place after template attachment to single beads”
The paper relies on this without support.
The ABRF-NGS Study is the largest reported cross-platform, cross-protocol, cross-site examination of RNA-seq data to date.
“This ABRF-NGS Study represents, to our knowledge, the largest reported cross-platform, cross-protocol, and cross-site examination of RNA-seq data performed to date”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A higher total read depth for RNA-seq samples increases the accuracy of the expression measurements, especially for genes with low expression.
“A higher total read depth for RNA-seq samples increases the accuracy of the expression measurements, especially for genes with low expression [21, 59].”
From Gene co-expression analysis for functional classification and gene–disease predictions (2017) · cites this paper as [59]
The Results (Transcriptome profiling and splice junction detection; page unavailable) suggest that rare-isoform quantification benefits most from greater read depth. The Discussion (page unavailable) says deeper sequencing is needed to reveal low-abundance transcripts. These passages support the low-expression part of the claim, but do not establish that higher read depth generally increases the accuracy of expression measurements. (LLM, conf=0.82)
Experimental — accuracy not yet measuredIncreased sample sizes produce networks with a higher functional connectivity.
“To create co-expression networks from RNA-seq data, a 20-sample minimum has been suggested [21, 54], and increased sample sizes produce networks with a higher functional connectivity [21, 59].”
From Gene co-expression analysis for functional classification and gene–disease predictions (2017) · cites this paper as [59]
The Results passages compare RNA-seq platforms, read depth, and gene detection; the Discussion addresses cross-platform reproducibility. None addresses whether increasing the number of samples improves the functional connectivity of co-expression networks. Searches for functional connectivity, co-expression networks, and larger biological sample sizes found no supporting passage in our copy. (LLM, conf=0.72)
Experimental — accuracy not yet measuredHigher quality data tend to result in more accurate co-expression networks.
“Not surprisingly, higher quality data tend to result in more accurate co-expression networks [21, 59].”
From Gene co-expression analysis for functional classification and gene–disease predictions (2017) · cites this paper as [59]
The Results sections on data quality and transcriptome profiling assess sequencing quality, gene quantification, and reproducibility, but do not assess co-expression networks. Searches for co-expression networks and network accuracy found no passage connecting data quality to network accuracy. (LLM, conf=0.72)
Experimental — accuracy not yet measuredPCR is affected by GC bias, and considerable differences in expression level measurements from different PCR based assays can be observed.
“PCR is affected by GC bias 21 , and considerable differences in expression level measurements from different PCR based assays can be observed (Fig. 5d).”
From A comprehensive assessment of RNA-seq accuracy, reproducibility and information content by the Sequencing Quality Control Consortium (2014) · cites this paper as [21]
The citation is attached to the statement that PCR is affected by GC bias. The Results section on base qualities says reverse-transcriptase priming can affect observed GC content, but does not say that GC content biases PCR. Searches for PCR amplification and GC bias found no passage in our copy making that connection; the later statement about differences between PCR-based assays is tied to the citing paper’s Fig. 5d, not this citation. (LLM, conf=0.70)
Experimental — accuracy not yet measuredAcross ABRF protocols, the shape of fragment GC dependence changed little, but positional bias showed a strong effect, with poly-A selected samples having highest coverage at the 3' end.
“We observed little change in the shape of fragment GC dependence across protocol, and a strong effect in the positional bias, with poly-A selected samples having highest coverage at the 3’ end of transcripts, as reported by the ABRF study authors29”
From Modeling of RNA-seq fragment sequence bias reduces systematic errors in transcript abundance estimation (2016) · cites this paper as [29]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
RNA-Seq Atlas citation points to a different resource
MinorThe text cites reference 45 for the RNA-Seq Atlas, but reference 45 names a non-human primate transcriptome resource. The RNA-Seq Atlas is listed as reference 46.
“such as the RNA-Seq Atlas45.”
“45. Pipes L The non-human primate reference transcriptome resource (NHPRTR) for comparative functional genomics Nucleic acids research 2013 41 D906 914 23203872 10.1093/nar/gks1268 PMC3531109”
The citation lists haven’t been fetched yet
References 58 · Cited by 240
- Authors
- Li, S., Tighe, S. W., Nicolet, C. M., Grove, D., Levy, S., Farmerie, W., Viale, A., Wright, C., Schweitzer, P. A., Gao, Y., Kim, D., Boland, J., Hicks, B., Kim, R., Chhangawala, S., Jafari, N., Raghavachari, N., Gandara, J., Garcia-Reyero, N., Hendrickson, C., Roberson, D., Rosenfeld, J. A., Smith, T., Underwood, J. G., Wang, M., Zumbo, P., Baldwin, D. A., Grills, G. S., & Mason, C. E.
- Affiliations
- Cornell University (US)
- University of Vermont (US)
- University of Southern California (US)
- Pennsylvania State University (US)
- HudsonAlpha Institute for Biotechnology (US)
- University of Florida (US)
- Memorial Sloan Kettering Cancer Center (US)
- University of Illinois Urbana-Champaign (US)
- Johns Hopkins University (US)
- National Cancer Institute (US)
- University of California, Davis (US)
- Northwestern University (US)
- National Institutes of Health (US)
- University of Medicine and Dentistry of New Jersey (US)
- PerkinElmer (United States) (US)
- University of Washington (US)
- Georgia Institute of Technology (US)
- Corresponding author
- Baldwin, Don A
- Grills, George S
- Mason, Christopher E
- ORCID
- Venue
- Nature Biotechnology
- Published
- 2014-08-24
- Volume
- 32
- Issue
- 9
- Pages
- 915-925
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- PMC
- PMC4167418
- OpenAlex
- W2073380432
- Semantic Scholar
- 542088d11897475b4ee48cf615daa225c8d947ee
- Cited by
- 240
- References
- 58
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 13 · 2023: 7 · 2022: 14 · 2021: 33 · 2020: 12 · 2019: 21 · 2018: 15 · 2017: 28 · 2016: 37 · 2015: 30 · 2014: 13
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Update notices
- erratum (2014-11-07)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Monique Weill-Caulier Trust
- National Institutes of Health (R24OD011172)
- National Human Genome Research Institute (R01HG006798)
- National Cancer Institute (U10CA180827)
- National Institute of Neurological Disorders and Stroke (R01NS076465)
- National Center for Research Resources (R24RR032341)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
- Keywords
- RNA-seq, gene expression profiling, rRNA depletion, poly(A) selection, degraded RNA, sequencing platform comparison, splice junction detection, variant calling
- MeSH terms
- Gene Expression Profiling, High-Throughput Nucleotide Sequencing, Transcriptome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-05.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-05.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review