Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 21 of the 24 references it cites were found in a registry or an index.

Biases in Illumina transcriptome sequencing caused by random hexamer priming

Open access
Hansen, Kasper D., Brenner, Steven E., Dudoit, Sandrine · 2010 · Nucleic Acids Research

Abstract

Generation of cDNA using random hexamer priming induces biases in the nucleotide composition at the beginning of transcriptome sequencing reads from the Illumina Genome Analyzer. The bias is independent of organism and laboratory and impacts the uniformity of the reads along the transcriptome. We provide a read count reweighting scheme, based on the nucleotide frequencies of the reads, that mitigates the impact of the bias.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nar/gkq224

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. Nucleotide frequencies versus position for stringently mapped reads. For each experiment, mapped reads were extended upstream of the 5′-start position, such that the first position of the actual read is 1 and positions 0 to −20 are obtained from the genome. The first hexamer of the read is shaded. Brief experimental protocols are indicated in the key. (a) RNA-Seq experiments conducted using priming with random hexamers, with and without RNA fragmentation. (b) DNA resequencing and ChIP-Seq experiments. (c) RNA-Seq experiments with alternative library preparation protocols, including priming with random hexamers followed by fragmentation using DNase I and priming with oligo(dT) followed by fragmentation using either DNase I, nebulization or sonication.
Figure 1. Nucleotide frequencies versus position for stringently mapped reads. For each experiment, mapped reads were extended upstream of the 5′-start position, such that the first position of the actual read is 1 and positions 0 to −20 are obtained from the genome. The first hexamer of the read is shaded. Brief experimental protocols are indicated in the key. (a) RNA-Seq experiments conducted using priming with random hexamers, with and without RNA fragmentation. (b) DNA resequencing and ChIP-Seq experiments. (c) RNA-Seq experiments with alternative library preparation protocols, including priming with random hexamers followed by fragmentation using DNase I and priming with oligo(dT) followed by fragmentation using either DNase I, nebulization or sonication.CC BY-NC · PubMed Central
Figure 2. Hexamer frequencies. (a) The logarithm (base 2) of all (4096) observed hexamer frequencies computed using positions 1–6 of the aligned reads for an experiment in H. sapiens (8) versus an experiment in S. cerevisiae (9). The two distributions have a correlation of . (b) As in (a), but the hexamers correspond to positions 25–30 of the aligned reads, with a correlation of .
Figure 2. Hexamer frequencies. (a) The logarithm (base 2) of all (4096) observed hexamer frequencies computed using positions 1–6 of the aligned reads for an experiment in H. sapiens (8) versus an experiment in S. cerevisiae (9). The two distributions have a correlation of . (b) As in (a), but the hexamers correspond to positions 25–30 of the aligned reads, with a correlation of .CC BY-NC · PubMed Central
Figure 3. Nucleotide frequencies versus position for stringently mapped stranded reads for the A nucleotide. (a and b) As in Figure 1a, but split according to whether reads map to the sense or antisense strand. (c) Difference between the frequencies in (a and b).
Figure 3. Nucleotide frequencies versus position for stringently mapped stranded reads for the A nucleotide. (a and b) As in Figure 1a, but split according to whether reads map to the sense or antisense strand. (c) Difference between the frequencies in (a and b).CC BY-NC · PubMed Central
Figure 4. Evaluation of the reweighting scheme. (a and b) Unadjusted and re-weighted base-level counts for reads from the WT experiment mapped to the sense strand of a 1-kb coding region in S. cerevisiae (YOL086C). The graey bars near the x-axis indicate unmappable genomic locations. (c) The goodness-of-fit statistics based on unadjusted and reweighted counts for 552 highly expressed regions of constant expression. (d) Smoothed histograms of the reduction in goodness-of-fit statistics when using the re-weighting scheme, evaluated in five different experiments. Values greater than zero indicate that the re-weighting scheme improves the uniformity of the read distribution.
Figure 4. Evaluation of the reweighting scheme. (a and b) Unadjusted and re-weighted base-level counts for reads from the WT experiment mapped to the sense strand of a 1-kb coding region in S. cerevisiae (YOL086C). The graey bars near the x-axis indicate unmappable genomic locations. (c) The goodness-of-fit statistics based on unadjusted and reweighted counts for 552 highly expressed regions of constant expression. (d) Smoothed histograms of the reduction in goodness-of-fit statistics when using the re-weighting scheme, evaluated in five different experiments. Values greater than zero indicate that the re-weighting scheme improves the uniformity of the read distribution.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 728

Metadata

Authors
Hansen, K. D., Brenner, S. E., & Dudoit, S.
Affiliations
University of California, Berkeley (US)
Corresponding author
Hansen, Kasper D.
Venue
Nucleic Acids Research
Published
2010-04-14
Volume
38
Issue
12
Pages
e131-e131
ISSN
  • 0305-1048 (ISSN-L)
  • 1362-4962
OpenAlex
W2154537630
Cited by
713
References
24
Citations by year
2026: 13 · 2025: 24 · 2024: 26 · 2023: 32 · 2022: 35 · 2021: 45 · 2020: 40 · 2019: 45 · 2018: 54 · 2017: 55 · 2016: 58 · 2015: 44 · 2014: 82 · 2013: 48 · 2012: 62
FWCI
20.73
Type
journal article
Language
en
Open access
Locations
  • Nucleic Acids Research (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by-nc)
  • HighWire Press Open Archive (submittedVersion)
Funders
  • National Institutes of Health
  • National Human Genome Research Institute (U01HG004271)
  • National Institute of General Medical Sciences (R01GM071655)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Gene expression and cancer classification
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
Keywords
cDNA library preparation, nucleotide composition bias, RNA-seq
MeSH terms
Nucleotides, Sequence Analysis, DNA, DNA Primers, Gene Expression Profiling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biases in Illumina transcriptome sequencing caused by random hexamer priming. https://app.cochat.ai/papers/10.1093/nar/gkq224
The paper
Hansen, K. D., Brenner, S. E., & Dudoit, S. (2010). Biases in Illumina transcriptome sequencing caused by random hexamer priming. Nucleic Acids Research. https://doi.org/10.1093/nar/gkq224

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.