The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Sensing of proteins in human serum using conjugates of nanoparticles and green fluorescent protein
Open accessAbstract
There is a direct correlation between protein levels and disease states in human serum making it an attractive target for sensors and diagnostics. However this is made challenging because serum features more than 20,000 proteins with an overall protein content of greater than 1 mM. Here we report a hybrid synthetic-biomolecule based sensor that uses green fluorescent protein-nanoparticle arrays to detect proteins at biorelevant concentrations in both buffer and human serum. Distinct and reproducible fluorescence response patterns were obtained from five serum proteins (human serum albumin, immunoglobulin G, transferrin, fibrinogen and α-antitrypsin) in buffer and when spiked into human serum. Using linear discriminant analysis we identified these proteins with an identification accuracy of 100% in buffer and 97% in human serum. The arrays were also able to discriminate between different concentrations of the same protein as well as a mixture of different proteins in human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Amyloid Hypothesis of Alzheimer’s Disease: Progress and Problems on the Road to Therapeutics
Hardy, J., & Selkoe, D. J. (2002) · Science · doi:10.1126/science.1072994 · Cited by 13,864
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Clinical diagnosis and management by laboratory methods
Henry, J. B. (1979) · Medical Entomology and Zoology · Cited by 1,691
Li, J., Zhang, Z., Rosenzweig, J., Wang, Y. Y., & Chan, D. W. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.8.1296 · Cited by 893
Toward a Human Blood Serum Proteome
Adkins, J. N., Varnum, S. M., Auberry, K. J., Moore, R. J., Angell, N. H., Smith, R. D., Springer, D. L., & Pounds, J. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200066-mcp200 · Cited by 793
You, C.-C., Miranda, O. R., Gider, B., Ghosh, P. S., Kim, I.-B., Erdogan, B., Krovi, S. A., Bunz, U. H. F., & Rotello, V. M. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.99 · Cited by 776
Self-citationBaggerly, K. A., Morris, J. S., & Coombes, K. R. (2004) · Bioinformatics · doi:10.1093/bioinformatics/btg484 · Cited by 621
Computational Methods for the Analysis of Chemical Sensor Array Data from Volatile Analytes
Jurs, P. C., Bakken, G. A., & McClelland, H. E. (2000) · Chemical Reviews · doi:10.1021/cr9800964 · Cited by 588
Cited by
Gold Nanoparticles in Chemical and Biological Sensing
Saha, K., Agasti, S. S., Kim, C., Li, X., & Rotello, V. M. (2012) · Chemical Reviews · doi:10.1021/cr2001178 · Cited by 4,620
Self-citationDiverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Self-citationGold nanoparticles: preparation, properties, and applications in bionanotechnology
Yeh, Y.-C., Creran, B., & Rotello, V. M. (2012) · Nanoscale · doi:10.1039/c1nr11188d · Cited by 1,346
Self-citationThe Optoelectronic Nose: Colorimetric and Fluorometric Sensor Arrays
Li, Z., Askim, J. R., & Suslick, K. S. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00226 · Cited by 1,191
Water-Soluble Conjugated Polymers for Imaging, Diagnosis, and Therapy
Zhu, C., Liu, L., Yang, Q., Lv, F., & Wang, S. (2012) · Chemical Reviews · doi:10.1021/cr200263w · Cited by 1,170
A bioorthogonal system reveals antitumour immune function of pyroptosis
Wang, Q., Wang, Y., Ding, J., Wang, C., Zhou, X., Gao, W., Huang, H., Shao, F., & Liu, Z. (2020) · Nature · doi:10.1038/s41586-020-2079-1 · Cited by 1,083
Recent Advances in Supramolecular Analytical Chemistry Using Optical Sensing
You, L., Zha, D., & Anslyn, E. V. (2015) · Chemical Reviews · doi:10.1021/cr5005524 · Cited by 969
Yao, J., Yang, M., & Duan, Y. (2014) · Chemical Reviews · doi:10.1021/cr200359p · Cited by 944
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Protein Corona-Mediated Mitigation of Cytotoxicity of Graphene Oxide
Hu, W., Peng, C., Lv, M., Li, X., Zhang, Y., Chen, N., Fan, C., & Huang, Q. (2011) · ACS Nano · doi:10.1021/nn200021j · Cited by 895
Optical sensor arrays for chemical sensing: the optoelectronic nose
Askim, J. R., Mahmoudi, M., & Suslick, K. S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60179j · Cited by 886
Intrinsic therapeutic applications of noble metal nanoparticles: past, present and future
Arvizo, R. R., Bhattacharyya, S., Kudgus, R. A., Giri, K., Bhattacharya, R., & Mukherjee, P. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15355f · Cited by 866
Self-citationSurface functionalization of nanoparticles for nanomedicine
Mout, R., Moyano, D. F., Rana, S., & Rotello, V. M. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15294k · Cited by 802
Self-citationGold nanoparticle-enabled biological and chemical detection and analysis
Jans, H., & Huo, Q. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15280g · Cited by 725
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Ligand Conjugation of Chemically Exfoliated MoS2
Chou, S. S., De, M., Kim, J., Byun, S., Dykstra, C., Yu, J., Huang, J., & Dravid, V. P. (2013) · Journal of the American Chemical Society · doi:10.1021/ja310929s · Cited by 564
Self-citationKrämer, J., Kang, R., Grimm, L. M., De Cola, L., Picchetti, P., & Biedermann, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00746 · Cited by 449
Nanoparticles and their applications in cell and molecular biology
Wang, E. C., & Wang, A. Z. (2014) · Integrative Biology · doi:10.1039/c3ib40165k · Cited by 415
Modulating Pharmacokinetics, Tumor Uptake and Biodistribution by Engineered Nanoparticles
Arvizo, R. R., Miranda, O. R., Moyano, D. F., Walden, C. A., Giri, K., Bhattacharya, R., Robertson, J. D., Rotello, V. M., Reid, J. M., & Mukherjee, P. (2011) · PLoS ONE · doi:10.1371/journal.pone.0024374 · Cited by 403
Self-citationThe Role of Surface Functionality in Determining Nanoparticle Cytotoxicity
Kim, S. T., Saha, K., Kim, C., & Rotello, V. M. (2013) · Accounts of Chemical Research · doi:10.1021/ar3000647 · Cited by 403
Self-citationA repertoire of biomedical applications of noble metal nanoparticles
Azharuddin, M., Zhu, G. H., Das, D., Ozgur, E., Uzun, L., Turner, A. P. F., & Patra, H. K. (2019) · Chemical Communications · doi:10.1039/c9cc01741k · Cited by 395
A practical approach to optical cross-reactive sensor arrays
Anzenbacher, Jr., Lubal, P., Buček, P., Palacios, M. A., & Kozelkova, M. E. (2010) · Chemical Society Reviews · doi:10.1039/b926220m · Cited by 379
Colorimetric Bacteria Sensing Using a Supramolecular Enzyme–Nanoparticle Biosensor
Miranda, O. R., Li, X., Garcia-Gonzalez, L., Zhu, Z.-J., Yan, B., Bunz, U. H. F., & Rotello, V. M. (2011) · Journal of the American Chemical Society · doi:10.1021/ja2021729 · Cited by 359
Self-citationGold Nanoparticle–Fluorophore Complexes: Sensitive and Discerning “Noses” for Biosystems Sensing
Bunz, U. H. F., & Rotello, V. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906928 · Cited by 357
Self-citationColorimetric sensor array based on gold nanoparticles: Design principles and recent advances
Sun, J., Lu, Y., He, L., Pang, J., Yang, F., & Liu, Y. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115754 · Cited by 299
Toward Ubiquitous Environmental Gas Sensors—Capitalizing on the Promise of Graphene
Ratinac, K. R., Yang, W., Ringer, S. P., & Braet, F. (2010) · Environmental Science & Technology · doi:10.1021/es902659d · Cited by 284
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Array‐based “Chemical Nose” Sensing in Diagnostics and Drug Discovery
Geng, Y., Peveler, W. J., & Rotello, V. M. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201809607 · Cited by 269
Self-citationRecent Progress in Sensor Arrays: From Construction Principles of Sensing Elements to Applications
Li, T., Zhu, X., Hai, X., Bi, S., & Zhang, X. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02596 · Cited by 257
Sun, M., Hong, C.-Y., & Pan, C.-Y. (2012) · Journal of the American Chemical Society · doi:10.1021/ja310236m · Cited by 255
Exploiting the Protein Corona around Gold Nanorods for Loading and Triggered Release
Kah, J. C. Y., Chen, J., Zubieta, A., & Hamad-Schifferli, K. (2012) · ACS Nano · doi:10.1021/nn301389c · Cited by 178
Metadata
- Authors
- De, M., Rana, S., Akpinar, H., Miranda, O. R., Arvizo, R. R., Bunz, U. H. F., & Rotello, V. M.
- Venue
- Nature Chemistry
- Published
- 2009-08-24
- Volume
- 1
- Issue
- 6
- Pages
- 461-465
- ISSN
- 1755-4330 (ISSN-L)
- 1755-4349
- OpenAlex
- W2079737565
- Cited by
- 488
- References
- 23
- FWCI
- 11.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.