The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Optical virtual imaging at 50 nm lateral resolution with a white-light nanoscope
Open accessAbstract
The imaging resolution of a conventional optical microscope is limited by diffraction to ~200 nm in the visible spectrum. Efforts to overcome such limits have stimulated the development of optical nanoscopes using metamaterial superlenses, nanoscale solid immersion lenses and molecular fluorescence microscopy. These techniques either require an illuminating laser beam to resolve to 70 nm in the visible spectrum or have limited imaging resolution above 100 nm for a white-light source. Here we report a new 50-nm-resolution nanoscope that uses optically transparent microspheres (for example, SiO₂, with 2 μm<diameter<9 μm) as far-field superlenses (FSL) to overcome the white-light diffraction limit. The microsphere nanoscope operates in both transmission and reflection modes, and generates magnified virtual images with a magnification up to ×8. It may provide new opportunities to image viruses and biomolecules in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
Whitesides, G. M., & Grzybowski, B. (2002) · Science · doi:10.1126/science.1070821 · Cited by 7,439
Sub-Diffraction-Limited Optical Imaging with a Silver Superlens
Fang, N., Lee, H., Sun, C., & Zhang, X. (2005) · Science · doi:10.1126/science.1108759 · Cited by 3,968
Richards, B., & Wolf, E. (1959) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1959.0200 · Cited by 3,095
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Plasmonic photothermal therapy (PPTT) using gold nanoparticles
Huang, X., Jain, P. K., El-Sayed, I. H., & El-Sayed, M. A. (2008) · Lasers in Medical Science · doi:10.1007/s10103-007-0470-x · Cited by 2,376
Far-Field Optical Hyperlens Magnifying Sub-Diffraction-Limited Objects
Liu, Z., Lee, H., Xiong, Y., Sun, C., & Zhang, X. (2007) · Science · doi:10.1126/science.1137368 · Cited by 2,177
Self-citationWeiner, J., & Ho, P.-T. (2003) · Wiley eBooks · Cited by 2,020
Optical Hyperlens: Far-field imaging beyond the diffraction limit
Jacob, Z., Alekseyev, L. V., & Narimanov, E. (2006) · Optics Express · doi:10.1364/oe.14.008247 · Cited by 1,551
Superlenses to overcome the diffraction limit
Zhang, X., & Liu, Z. (2008) · Nature Materials · doi:10.1038/nmat2141 · Cited by 1,320
Self-citationScanning near-field optical microscopy with aperture probes: Fundamentals and applications
Hecht, B., Sick, B., Wild, U. P., Deckert, V., Zenobi, R., Martin, O. J. F., & Pohl, D. W. (2000) · The Journal of Chemical Physics · doi:10.1063/1.481382 · Cited by 761
Magnifying Superlens in the Visible Frequency Range
Smolyaninov, I. I., Hung, Y.-J., & Davis, C. C. (2007) · Science · doi:10.1126/science.1138746 · Cited by 730
Potton, R. J. (2004) · Reports on Progress in Physics · doi:10.1088/0034-4885/67/5/r03 · Cited by 625
Near-Field Microscopy Through a SiC Superlens
Taubner, T., Korobkin, D., Urzhumov, Y., Shvets, G., & Hillenbrand, R. (2006) · Science · doi:10.1126/science.1131025 · Cited by 597
Atomically flat single-crystalline gold nanostructures for plasmonic nanocircuitry
Huang, J.-S., Callegari, V., Geisler, P., Brüning, C., Kern, J., Prangsma, J. C., Wu, X., Feichtner, T., Ziegler, J., Weinmann, P., et al. (2010) · Nature Communications · doi:10.1038/ncomms1143 · Cited by 455
Spherical hyperlens for two-dimensional sub-diffractional imaging at visible frequencies
Rho, J., Ye, Z., Xiong, Y., Yin, X., Liu, Z., Choi, H., Bartal, G., & Zhang, X. (2010) · Nature Communications · doi:10.1038/ncomms1148 · Cited by 434
Self-citationLiu, Z., Durant, S., Lee, H., Pikus, Y., Fang, N., Xiong, Y., Sun, C., & Zhang, X. (2007) · Nano Letters · doi:10.1021/nl062635n · Cited by 395
Self-citationNear-field focusing and magnification through self-assembled nanoscale spherical lenses
Lee, J. Y., Hong, B. H., Kim, W. Y., Min, S. K., Kim, Y., Jouravlev, M. V., Bose, R., Kim, K. S., Hwang, I.-C., Kaufman, L. J., et al. (2009) · Nature · doi:10.1038/nature08173 · Cited by 384
Diffraction-unlimited three-dimensional optical nanoscopy with opposing lenses
Hell, S. W., Schmidt, R., & Egner, A. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.112 · Cited by 143
Realization of numerical aperture 2.0 using a gallium phosphide solid immersion lens
Wu, Q., Feke, G. D., Grober, R. D., & Ghislain, L. P. (1999) · Applied Physics Letters · doi:10.1063/1.125537 · Cited by 126
Cited by
Principles of electromagnetic waves in metasurfaces
Luo, X. (2015) · Science China Physics, Mechanics & Astronomy · doi:10.1007/s11433-015-5688-1 · Cited by 580
Sapsford, K. E., Tyner, K. M., Dair, B. J., Deschamps, J. R., & Medintz, I. L. (2011) · Analytical Chemistry · doi:10.1021/ac200853a · Cited by 538
Label-free super-resolution imaging of adenoviruses by submerged microsphere optical nanoscopy
Li, L., Guo, W., Yan, Y., Lee, S., & Wang, T. (2013) · Light: Science & Applications · doi:10.1038/lsa.2013.60 · Cited by 295
Self-citationCharacteristics of nano-plastics in bottled drinking water
Huang, Y., Wong, K. K., Li, W., Zhao, H., Wang, T., Stanescu, S., Boult, S., van Dongen, B., Mativenga, P., & Li, L. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127404 · Cited by 84
Self-citation
Metadata
- Authors
- Wang, Z., Guo, W., Li, L., Luk'yanchuk, B., Khan, A., Liu, Z., Chen, Z., & Hong, M.
- Venue
- Nature Communications
- Published
- 2011-03-01
- Volume
- 2
- Issue
- 1
- Pages
- 218-218
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2011605930
- Cited by
- 827
- References
- 20
- FWCI
- 20.24
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.