Real-time in vivo imaging of the beating mouse heart at microscopic resolution
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Real-time imaging of moving organs and tissues at microscopic resolutions represents a major challenge in studying the complex biology of live animals. Here we present a technique based on a novel stabilizer setup combined with a gating acquisition algorithm for the imaging of a beating murine heart at the single-cell level. The method allows serial in vivo fluorescence imaging of the beating heart in live mice in both confocal and nonlinear modes over the course of several hours. We demonstrate the utility of this technique for in vivo optical sectioning and dual-channel time-lapse fluorescence imaging of cardiac ischaemia. The generic method could be adapted to other moving organs and thus broadly facilitate in vivo microscopic investigations. Microscopic imaging techniques have a high spatio-temporal resolution but, in living animals, are hampered by cardiac and respiratory motion. This paper describes a microscopic setup that allows fluorescent confocal imaging of the beating mouse heart over a period of several hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image denoising by sparse 3-D transform-domain collaborative filtering
Dabov, K., Foi, A., Katkovnik, V., & Egiazarian, K. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.901238 · Cited by 9,283
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Therapeutic siRNA silencing in inflammatory monocytes in mice
Leuschner, F., Dutta, P., Gorbatov, R., Novobrantseva, T. I., Donahoe, J. S., Courties, G., Lee, K. M., Kim, J. I., Markmann, J. F., Marinelli, B., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1989 · Cited by 839
Self-citation
Cited by
IRF3 and type I interferons fuel a fatal response to myocardial infarction
King, K. R., Aguirre, A. D., Ye, Y.-X., Sun, Y., Roh, J. D., Ng, R. P., Kohler, R. H., Arlauckas, S. P., Iwamoto, Y., Savol, A., et al. (2017) · Nature Medicine · doi:10.1038/nm.4428 · Cited by 570
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Miao, Q., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801778 · Cited by 537
Monocyte and Macrophage Heterogeneity in the Heart
Nahrendorf, M., & Swirski, F. K. (2013) · Circulation Research · doi:10.1161/circresaha.113.300890 · Cited by 359
Self-citationCardiac macrophages and their role in ischaemic heart disease
Frantz, S., & Nahrendorf, M. (2014) · Cardiovascular Research · doi:10.1093/cvr/cvu025 · Cited by 310
Self-citation
Metadata
- Authors
- Lee, S., Vinegoni, C., Feruglio, P. F., Fexon, L., Gorbatov, R., Pivoravov, M., Sbarbati, A., Nahrendorf, M., & Weissleder, R.
- Venue
- Nature Communications
- Published
- 2012-09-11
- Volume
- 3
- Issue
- 1
- Pages
- 1054-1054
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2072154150
- Cited by
- 142
- References
- 3
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.