Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 220

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Multiplexed volumetric bar-chart chip for point-of-care diagnostics

Open access
Song, Yujun, Zhang, Yuanqing, Bernard, Paul E., Reuben, James M., Ueno, Naoto T., Arlinghaus, Ralph B., Zu, Youli, Qin, Lidong·2012·Nature Communications

Abstract

Microfluidics have become an enabling technology for point-of-care and personalized diagnostics. Desirable capabilities of microfluidics-based diagnostic devices include simplicity, portability, low cost and the performance of multiplexed and quantitative measurements, ideally in a high-throughput format. Here we present the multiplexed volumetric bar-chart chip (V-Chip), which integrates all these capabilities in one device. A key feature of the V-Chip is that quantitative results are displayed as bar charts directly on the device—without the need for optical instruments or any data processing or plotting steps. This is achieved by directly linking oxygen production by catalase, which is proportional to the concentration of the analyte, with the displacement of ink along channels on the device. We demonstrate the rapid quantification of protein biomarkers in diverse clinical samples with the V-Chip. The development of the V-Chip thus opens up the possibility of greatly simplified point-of-care and personalized diagnostics. Diagnostic microfluidic devices often require complicated optical systems and computers to quantify results. Here, Qin and colleagues link enzymatic biomarker detection with the displacement of ink, resulting in a device that displays quantitative results as bar graphs directly on the device.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ncomms2292

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 220

Metadata

Authors
Song, Y., Zhang, Y., Bernard, P. E., Reuben, J. M., Ueno, N. T., Arlinghaus, R. B., Zu, Y., & Qin, L.
Venue
Nature Communications
Published
2012-12-18
Volume
3
Issue
1
Pages
1283-1283
ISSN
2041-1723 (ISSN-L)
OpenAlex
W1976704354
Cited by
220
References
4
FWCI
8.02
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiplexed volumetric bar-chart chip for point-of-care diagnostics. https://app.cochat.ai/papers/10.1038/ncomms2292
The paper
Song, Y., Zhang, Y., Bernard, P. E., Reuben, J. M., Ueno, N. T., Arlinghaus, R. B., Zu, Y., & Qin, L. (2012). Multiplexed volumetric bar-chart chip for point-of-care diagnostics. Nature Communications. https://doi.org/10.1038/ncomms2292

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.