The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
A model for harmonizing flow cytometry in clinical trials
Open accessAbstract
Complexities in sample handling, instrument setup and data analysis are barriers to the effective use of flow cytometry to monitor immunological parameters in clinical trials. The novel use of a central laboratory may help mitigate these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Inter-laboratory variations are also an issue, with Maecker et al. having reported that individual laboratories typically experience a ~20% CV in the data analysis, whereas data from a central laboratory only shows a variance of ~4% [19].”
From Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition) (2021) · cites this paper as [19]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seventeen-colour flow cytometry: unravelling the immune system
Perfetto, S. P., Chattopadhyay, P. K., & Roederer, M. (2004) · Nature Reviews Immunology · doi:10.1038/nri1416 · Cited by 1,019
Spectral compensation for flow cytometry: Visualization artifacts, limitations, and caveats
Roederer, M. (2001) · Cytometry · doi:10.1002/1097-0320(20011101)45:3 · Cited by 561
MIFlowCyt: The minimum information about a flow cytometry experiment
Lee, J. A., Spidlen, J., Boyce, K., Cai, J., Crosbie, N., Dalphin, M., Furlong, J., Gasparetto, M., Goldberg, M., Goralczyk, E. M., et al. (2008) · Cytometry Part A · doi:10.1002/cyto.a.20623 · Cited by 533
Flow cytometry controls, instrument setup, and the determination of positivity
Maecker, H. T., & Trotter, J. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20333 · Cited by 365
Self-citationA Prescription for Human Immunology
Davis, M. M. (2008) · Immunity · doi:10.1016/j.immuni.2008.12.003 · Cited by 346
Standardization of cytokine flow cytometry assays
Maecker, H. T., Rinfret, A., D’Souza, P., Darden, J. M., Roig, E., Landry, C., Hayes, P., Birungi, J., Anzala, O. A., Garcia, M., et al. (2005) · BMC Immunology · doi:10.1186/1471-2172-6-13 · Cited by 242
Self-citationSelecting fluorochrome conjugates for maximum sensitivity
Maecker, H. T., Frey, T., Nomura, L. E., & Trotter, J. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20092 · Cited by 219
Self-citationSleep associated regulation of T helper 1/T helper 2 cytokine balance in humans
Dimitrov, S., Lange, T., Tieken, S., Fehm, H. L., & Born, J. (2004) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2003.08.004 · Cited by 209
Weinberg, A., Song, L., Wilkening, C. L., Sevin, A. D., Blais, B., Louzao, R., Stein, D., Defechereux, P. A., Durand, D., Riedel, E., et al. (2009) · Clinical and Vaccine Immunology · doi:10.1128/cvi.00342-08 · Cited by 194
“MIATA”—Minimal Information about T Cell Assays
Janetzki, S., Britten, C. M., Kalos, M. D., Levitsky, H. I., Maecker, H. T., Melief, C. J. M., Old, L. J., Romero, P. J., Hoos, A., & Davis, M. M. (2009) · Immunity · doi:10.1016/j.immuni.2009.09.007 · Cited by 192
Self-citationSleep-dependent activity of T cells and regulatory T cells
Bollinger, T., Bollinger, A., Skrum, L., Dimitrov, S., Lange, T., & Solbach, W. (2009) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.2008.03822.x · Cited by 167
Evidence supporting a circadian control of natural killer cell function
Arjona, A., & Sarkar, D. K. (2005) · Brain Behavior and Immunity · doi:10.1016/j.bbi.2005.10.002 · Cited by 150
Analysis of T cell subsets in normal adults
RENZI, P. M., & Ginns, L. C. (1987) · Journal of Immunological Methods · doi:10.1016/0022-1759(87)90434-0 · Cited by 129
Lévi, F. A., Canon, C., Touitou, Y., Reinberg, A., & Mathé, G. (1988) · Journal of Clinical Investigation · doi:10.1172/jci113333 · Cited by 104
Lymphocyte immunophenotyping by flow cytometry in normal adults
AssumpcióRomeu, M., Mestre, M., González, L., Valls, A., Verdaguer, J., Corominas, M., Bas, J., Massip, E., & Buendia, E. (1992) · Journal of Immunological Methods · doi:10.1016/0022-1759(92)90206-9 · Cited by 90
Weinberg, A., Betensky, R. A., Zhang, L., & Ray, G. (1998) · Clinical and Diagnostic Laboratory Immunology · doi:10.1128/cdli.5.6.804-807.1998 · Cited by 83
Toward quantitative fluorescence measurements with multicolor flow cytometry
Wang, L., Gaigalas, A. K., Marti, G. E., Abbasi, F., & Hoffman, R. A. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20507 · Cited by 72
Immuno-monitoring of CD8+ T cells in whole blood versus PBMC samples
Appay, V., Reynard, S., Voelter, V., Romero, P. J., Speiser, D. E., & Leyvraz, S. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.11.007 · Cited by 58
Hodge, G. L., Flower, R. L., & Han, P. (1999) · Journal of Immunological Methods · doi:10.1016/s0022-1759(99)00025-3 · Cited by 57
Performance of plate-based cytokine flow cytometry with automated data analysis
Suni, M. A., Dunn, H. S., Orr, P. L., de Laat, R., Sinclair, E., Ghanekar, S., Bredt, B. M., Dunne, J. F., Maino, V. C., & Maecker, H. T. (2003) · BMC Immunology · doi:10.1186/1471-2172-4-9 · Cited by 53
Self-citationMultiparameter Flow Cytometry Monitoring of T Cell Responses
Maecker, H. T. (2009) · Methods in molecular biology · doi:10.1007/978-1-59745-170-3_25 · Cited by 46
Self-citationHoffmeister, B., Bunde, T., Rudawsky, I. M., Volk, H., & Kern, F. (2003) · European Journal of Immunology · doi:10.1002/eji.200324223 · Cited by 42
Increased immunofluorescence sensitivity using 532 nm laser excitation
Perfetto, S. P., & Roederer, M. (2007) · Cytometry Part A · doi:10.1002/cyto.a.20358 · Cited by 38
Shalekoff, S., Page‐Shipp, L., & Tiemessen, C. T. (1998) · Clinical and Diagnostic Laboratory Immunology · doi:10.1128/cdli.5.5.695-702.1998 · Cited by 30
Effects of cryopreservation on CD4+ CD25+ T cells of HIV‐1 infected individuals
Seale, A. C., de Jong, B. C., Zaidi, I., Duvall, M. G., Whittle, H. C., Rowland‐Jones, S., & Jaye, A. (2008) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20234 · Cited by 27
Kumar, P., & Satchidanandam, V. (2000) · Clinical and Diagnostic Laboratory Immunology · doi:10.1128/cdli.7.4.578-583.2000 · Cited by 26
Cited by
Sorted by citations
Standardizing immunophenotyping for the Human Immunology Project
Maecker, H. T., McCoy, J. P., & Nussenblatt, R. B. (2012) · Nature reviews. Immunology · doi:10.1038/nri3158 · Cited by 1,199
Self-citationGuidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdiş, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 1,007
Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition)
Cossarizza, A., Chang, H., Radbruch, A., Abrignani, S., Addo, R., Akdis, M., Andrä, I., Andreata, F., Annunziato, F., Arranz, E., et al. (2021) · European Journal of Immunology · doi:10.1002/eji.202170126 · Cited by 531
Separation, characterization and identification of microplastics and nanoplastics in the environment
Fu, W., Min, J., Jiang, W., Li, Y., & Zhang, W. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137561 · Cited by 384
Standardizing Flow Cytometry Immunophenotyping Analysis from the Human ImmunoPhenotyping Consortium
Finak, G., Langweiler, M., Jaimes, M. C., Malek, M., Taghiyar, M. J., Korin, Y. D., Raddassi, K., Devine, L., Obermoser, G., Pękalski, M. Ł., et al. (2016) · Scientific Reports · doi:10.1038/srep20686 · Cited by 286
“We transformed the proportion, (1): yrij=logit(prij), and model (2):”
MethodSelf-citation
Metadata
- Authors
- the FOCIS Human Immunophenotyping Consortium, Maecker, H. T., & McCoy, J. P.
- Affiliations
- Stanford University (US)
- National Institutes of Health (US)
- Corresponding author
- Maecker, Holden T
- Venue
- Nature Immunology
- Published
- 2010-10-19
- Volume
- 11
- Issue
- 11
- Pages
- 975-978
- ISSN
- 1529-2908 (ISSN-L)
- 1529-2916
- PMC
- PMC3400260
- OpenAlex
- W1497374306
- Cited by
- 155
- References
- 26
- Citations by year
- 2026: 3 · 2025: 6 · 2024: 7 · 2023: 7 · 2022: 9 · 2021: 10 · 2020: 6 · 2019: 14 · 2018: 10 · 2017: 8 · 2016: 12 · 2015: 16 · 2014: 10 · 2013: 11 · 2012: 14
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Update notices
- correction (2011-02-15)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Nature Immunology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- DukeSpace (Duke University) (submittedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- National Institutes of Health (Z99 HL999999)
- National Heart, Lung, and Blood Institute (Z01HL005905, ZICHL005905)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Life Sciences › Immunology and Microbiology › Immunology › T-cell and B-cell Immunology
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Keywords
- flow cytometry, clinical trials, harmonization, central laboratory, sample handling, instrument setup, data analysis, immune monitoring, standardization
- MeSH terms
- Clinical Trials as Topic, Flow Cytometry, Humans, Specimen Handling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review