Imaging the subcellular structure of human coronary atherosclerosis using micro–optical coherence tomography
Open accessAbstract
Progress in understanding, diagnosis, and treatment of coronary artery disease (CAD) has been hindered by our inability to observe cells and extracellular components associated with human coronary atherosclerosis in situ. The current standards for microstructural investigation, histology and electron microscopy are destructive and prone to artifacts. The highest-resolution intracoronary imaging modality, optical coherence tomography (OCT), has a resolution of ∼10 μm, which is too coarse for visualizing most cells. Here we report a new form of OCT, termed micro–optical coherence tomography (μOCT), whose resolution is improved by an order of magnitude. We show that μOCT images of cadaver coronary arteries provide clear pictures of cellular and subcellular features associated with atherogenesis, thrombosis and responses to interventional therapy. These results suggest that μOCT can complement existing diagnostic techniques for investigating atherosclerotic specimens, and that μOCT may eventually become a useful tool for cellular and subcellular characterization of the human coronary wall in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Lusis, A. J. (2000) · Nature · doi:10.1038/35025203 · Cited by 4,839
Virmani, R., Kolodgie, F. D., Burke, A. P., Farb, A., & Schwartz, S. M. (2000) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.20.5.1262 · Cited by 4,084
Stary, H. C., Chandler, A. B., Dinsmore, R. E., Fuster, V., Glagov, S., Insull, W., Rosenfeld, M. E., Schwartz, C. J., Wagner, W. D., & Wissler, R. W. (1995) · Circulation · doi:10.1161/01.cir.92.5.1355 · Cited by 3,533
Pathology of the Vulnerable Plaque
Virmani, R., Burke, A. P., Farb, A., & Kolodgie, F. D. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.065 · Cited by 2,315
Finn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277
Jang, I.-K., Bouma, B. E., Kang, D.-H., Park, S.-J., Park, S.-W., Seung, K.-B., Choi, K.-B., Shishkov, M., Schlendorf, K., Pomerantsev, E., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01799-5 · Cited by 1,000
Self-citationSerruys, P. W., Ormiston, J. A., Onuma, Y., Regar, E., Gonzalo, N., Garcia-Garcia, H. M., Nieman, K., Bruining, N., Dorange, C., Miquel-Hébert, K., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60325-1 · Cited by 820
Changing concepts of atherogenesis
Libby, P. (2000) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2000.00654.x · Cited by 626
Submicrometer axial resolution optical coherence tomography
Povazay, B., Bizheva, K., Unterhuber, A., Hermann, B., Sattmann, H., Fercher, A. F., Drexler, W., Apolonski, A., Wadsworth, W. J., Knight, J. C., et al. (2002) · Optics Letters · doi:10.1364/ol.27.001800 · Cited by 480
Comprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
Self-citationInterferometric synthetic aperture microscopy
Ralston, T. S., Marks, D. L., Scott Carney, P., & Boppart, S. A. (2007) · Nature Physics · doi:10.1038/nphys514 · Cited by 408
High-resolution optical coherence tomography over a large depth range with an axicon lens
Ding, Z., Ren, H., Zhao, Y., Nelson, J. S., & Chen, Z. (2002) · Optics Letters · doi:10.1364/ol.27.000243 · Cited by 367
Three-Dimensional Coronary Artery Microscopy by Intracoronary Optical Frequency Domain Imaging
Tearney, G. J., Waxman, S., Shishkov, M., Vakoc, B. J., Suter, M. J., Freilich, M. I., Desjardins, A. E., Oh, W.-Y., Bartlett, L. A., Rosenberg, M., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2008.06.007 · Cited by 324
Self-citationIn vivo cellular optical coherence tomography imaging
Boppart, S. A., Bouma, B. E., Pitris, C., Southern, J. F., Brezinski, M. E., & Fujimoto, J. G. (1998) · Nature Medicine · doi:10.1038/nm0798-861 · Cited by 268
Self-citationLee, K.-S., & Rolland, J. P. (2008) · Optics Letters · doi:10.1364/ol.33.001696 · Cited by 240
Acute coronary thrombosis--the role of plaque disruption and its initiation and prevention
Davies, M. J. (1995) · European Heart Journal · doi:10.1093/eurheartj/16.suppl_l.3 · Cited by 127
Abela, G. S., & Aziz, K. S. (2006) · Scanning · doi:10.1002/sca.4950280101 · Cited by 123
Vengrenyuk, Y., Cardoso, L., & Weinbaum, S. (2008) · PubMed · Cited by 101
Cited by
Acute Coronary Syndromes: The Way Forward From Mechanisms to Precision Treatment
Crea, F., & Libby, P. (2017) · Circulation · doi:10.1161/circulationaha.117.029870 · Cited by 476
Optical coherence tomography in coronary atherosclerosis assessment and intervention
Araki, M., Park, S.-J., Dauerman, H. L., Uemura, S., Kim, J.-S., Di Mario, C., Johnson, T. W., Guagliumi, G., Kastrati, A., Joner, M., et al. (2022) · Nature Reviews Cardiology · doi:10.1038/s41569-022-00687-9 · Cited by 430
Self-citationThe importance of the endothelium in atherothrombosis and coronary stenting
Otsuka, F., Finn, A. V., Yazdani, S. K., Nakano, M., Kolodgie, F. D., & Virmani, R. (2012) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2012.64 · Cited by 402
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Metadata
- Authors
- Liu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J.
- Venue
- Nature Medicine
- Published
- 2011-07-10
- Volume
- 17
- Issue
- 8
- Pages
- 1010-1014
- ISSN
- 1078-8956 (ISSN-L)
- 1546-170X
- OpenAlex
- W2055269249
- Cited by
- 463
- References
- 19
- FWCI
- 17.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.