Achieving better-than-3-Å resolution by single-particle cryo-EM at 200 keV
Open accessPublished version of a preprint
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Nearly all single-particle cryo-EM structures resolved to better than 4-Å resolution have been determined using 300-keV transmission electron microscopes (TEMs). We demonstrate that it is possible to obtain reconstructions of macromolecular complexes of different sizes to better than 3-Å resolution using a 200-keV TEM. These structures are of sufficient quality to unambiguously assign amino acid rotameric conformations and identify ordered water molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MolProbity : all-atom structure validation for macromolecular crystallography
Chen, V. B., Arendall, W. B., Headd, J. J., Keedy, D. A., Immormino, R. M., Kapral, G. J., Murray, L. W., Richardson, J. S., & Richardson, D. C. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909042073 · Cited by 14,115 · cited 1×
“Each of the 100 Rosetta-generated models 37 were ranked based on the number of Ramachandran outliers (%, lower better), geometry violations (%, lower better), Rosetta aggregate score (value, lower better), and MolProbity clashscore 38 (value, lower better).”
RELION: Implementation of a Bayesian approach to cryo-EM structure determination
Scheres, S. H. W. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.09.006 · Cited by 5,446 · cited 1×
“(11), SPARX (12), etc), and implementation of more powerful computational resources have led to visualization of biological macromolecular assemblies in near-native states”
BackgroundEMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Structures of the human and Drosophila 80S ribosome
Anger, A. M., Armache, J.-P., Berninghausen, O., Habeck, M., Subklewe, M., Wilson, D. N., & Beckmann, R. (2013) · Nature · doi:10.1038/nature12104 · Cited by 628
Outcome of the first electron microscopy validation task force meeting
Henderson, R., Sali, A., Baker, M. L., Carragher, B., Devkota, B., Downing, K. H., Egelman, E. H., Feng, Z., Frank, J., Grigorieff, N., et al. (2012) · Structure · doi:10.1016/j.str.2011.12.014 · Cited by 505 · cited 8×
“All reported resolutions are based on the gold-standard Fourier shell correlation (FSC) criterion 14 (see Methods ).”
InfluentialAutomated structure refinement of macromolecular assemblies from cryo-EM maps using Rosetta
Wang, R. Y.-R., Song, Y., Barad, B. A., Cheng, Y., Fraser, J. S., & DiMaio, F. (2016) · eLife · doi:10.7554/elife.17219 · Cited by 457
Research works printed but not linked: 35
- Merk, A. et al. Cell 165, 1698–1707 (2016). · DOI · Paper page
- Danev, R., Tegunov, D. & Baumeister, W. eLife 6, e23006 (2017). · DOI
- Henderson, R. Q. Rev. Biophys. 28, 171–193 (1995). · DOI · Paper page
- Campbell, M.G. et al. J. Struct. Biol. 188, 183–187 (2014). · DOI
- Li, X. et al. J. Mol. Biol. 429, 79–87 (2017). · doi:10.1016/j.jmb.2016.11.025
- Glaeser, R.M., Typke, D., Tiemeijer, P.C., Pulokas, J. & Cheng, A. J. Struct. Biol. 174, 1–10 (2011). · DOI
- Suloway, C. et al. J. Struct. Biol. 151, 41–60 (2005). · DOI · Paper page
- Lander, G.C. et al. J. Struct. Biol. 166, 95–102 (2009). · DOI · Paper page
- Russo, C.J. & Passmore, L.A. Science 346, 1377–1380 (2014). · DOI · Paper page
- Zheng, S.Q. et al. Nat. Methods 14, 331–332 (2017). · DOI · Paper page
- Rohou, A. & Grigorieff, N. J. Struct. Biol. 192, 216–221 (2015). · DOI · Paper page
- Zhang, K. J. Struct. Biol. 193, 1–12 (2016). · DOI · Paper page
- Kimanius, D., Forsberg, B.O., Scheres, S.H. & Lindahl, E. eLife 5, e18722 (2016). · DOI · Paper page
- Campbell, M.G., Veesler, D., Cheng, A., Potter, C.S. & Carragher, B. eLife 4, e06380 (2015). · DOI · Paper page
- Egerton, R.F. Ultramicroscopy 145, 85–93 (2014). · doi:10.1016/j.ultramic.2013.10.019
- Campbell, M.G. et al. Structure 20, 1823–1828 (2012). · DOI · Paper page
- Li, X. et al. Nat. Methods 10, 584–590 (2013). · DOI · Paper page
- Rubinstein, J.L. & Brubaker, M.A. J. Struct. Biol. 192, 188–195 (2015). · DOI · Paper page
- Grant, T. & Grigorieff, N. eLife 4, e06980 (2015). · DOI · Paper page
- Scheres, S.H. eLife 3, e03665 (2014). · DOI · Paper page
- Cheng, Y., Grigorieff, N., Penczek, P.A. & Walz, T. Cell 161, 438–449 (2015). · DOI · Paper page
- Khoshouei, M., Radjainia, M., Baumeister, W. & Danev, R. Nat. Commun. 8, 16099 (2017). · DOI · Paper page
- Herzik, M.A. Jr., Wu, M. & Lander, G.C. Setting up the Talos Arctica electron microscope and Gatan K2 direct detector for high-resolution cryogenic single-particle data acquisition. Protocol Exchange http://dx.doi.org/10.1038/protex.2017.108 (2017). · doi:10.1038/protex.2017.108
- Dubochet, J. et al. Q. Rev. Biophys. 21, 129–228 (1988). · DOI · Paper page
- Grassucci, R.A., Taylor, D. & Frank, J. Nat. Protoc. 3, 330–339 (2008). · DOI
- Voss, N.R., Yoshioka, C.K., Radermacher, M., Potter, C.S. & Carragher, B. J. Struct. Biol. 166, 205–213 (2009). · DOI · Paper page
- Ogura, T., Iwasaki, K. & Sato, C. J. Struct. Biol. 143, 185–200 (2003). · DOI
- Roseman, A.M. J. Struct. Biol. 145, 91–99 (2004). · DOI · Paper page
- Scheres, S.H. & Chen, S. Nat. Methods 9, 853–854 (2012). · DOI · Paper page
- Chen, S. et al. Ultramicroscopy 135, 24–35 (2013). · DOI · Paper page
- Punjani, A., Rubinstein, J.L., Fleet, D.J. & Brubaker, M.A. Nat. Methods 14, 290–296 (2017). · DOI · Paper page
- Cardone, G., Heymann, J.B. & Steven, A.C. J. Struct. Biol. 184, 226–236 (2013). · DOI · Paper page
- Herzik, M.A., Fraser, J.S. & Lander, G.C. A multi-model approach to assessing local and global cryo-EM map quality. Preprint at bioRxiv https://doi.org/10.1101/128561 (2017). · doi:10.1101/128561
- Apweiler, R. et al. Nucleic Acids Res. 32, D115–D119 (2004). · DOI · Paper page
- Adams, P.D. et al. Acta Crystallogr. D Biol. Crystallogr. 66, 213–221 (2010). · DOI · Paper page
Cited by
New tools for automated cryo-EM single-particle analysis in RELION-4.0
Kimanius, D., Dong, L., Sharov, G., Nakane, T., & Scheres, S. H. W. (2021) · Biochemical Journal · doi:10.1042/bcj20210708 · Cited by 1,086
Structure of the SARS-CoV nsp12 polymerase bound to nsp7 and nsp8 co-factors
Kirchdoerfer, R. N., & Ward, A. B. (2019) · Nature Communications · doi:10.1038/s41467-019-10280-3 · Cited by 896
Zivanov, J., Nakane, T., & Scheres, S. H. W. (2020) · IUCrJ · doi:10.1107/s2052252520000081 · Cited by 781
Cryo-EM in drug discovery: achievements, limitations and prospects
Renaud, J.-P., Chari, A., Ciferri, C., Liu, W.-T., Rémigy, H.-W., Stark, H., & Wiesmann, C. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2018.77 · Cited by 461
Radiation damage to organic and inorganic specimens in the TEM
Egerton, R. F. (2019) · Micron · doi:10.1016/j.micron.2019.01.005 · Cited by 450
Metadata
- Authors
- Herzik, M. A., Wu, M., & Lander, G. C.
- Venue
- Nature Methods
- Published
- 2017-10-09
- Volume
- 14
- Issue
- 11
- Pages
- 1075-1078
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2617175248
- Cited by
- 136
- References
- 6
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Achieving better-than-3-Å resolution by single-particle cryo-EM at 200 keV. https://app.cochat.ai/papers/10.1038/nmeth.4461
- The paper
- Herzik, M. A., Wu, M., & Lander, G. C. (2017). Achieving better-than-3-Å resolution by single-particle cryo-EM at 200 keV. Nature Methods. https://doi.org/10.1038/nmeth.4461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.