The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Free-standing kinked nanowire transistor probes for targeted intracellular recording in three dimensions
Open accessAbstract
Recording intracellular bioelectrical signals is central to understanding the fundamental behaviour of cells and cell-networks in, for example, neural and cardiac systems1–4. The standard tool for intracellular recording, the patch-clamp micropipette5 is widely applied, yet remains limited in terms of reducing the tip size, the ability to reuse the pipette5, and ion exchange with the cytoplasm6. Recent efforts have been directed towards developing new chip-based tools1–4,7–13, including micro-to-nanoscale metal pillars7–9, transistor-based kinked nanowire10,11 and nanotube devices12,13. These nanoscale tools are interesting with respect to chip-based multiplexing, but, to date, preclude targeted recording from specific cell regions and/or subcellular structures. Here we overcome this limitation in a general manner by fabricating free-standing probes where a kinked silicon nanowire with encoded field-effect transistor detector serves as the tip end. These probes can be manipulated in three dimensions (3D) within a standard microscope to target specific cells/cell regions, and record stable full-amplitude intracellular action potentials from different targeted cells without the need to clean or change the tip. Simultaneous measurements from the same cell made with free-standing nanowire and patch-clamp probes show that the same action potential amplitude and temporal properties are recorded without corrections to the raw nanowire signal. In addition, we demonstrate real-time monitoring of changes in the action potential as different ion-channel blockers are applied to cells, and multiplexed recording from cells by independent manipulation of two free-standing nanowire probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac excitation–contraction coupling
Bers, D. M. (2002) · Nature · doi:10.1038/415198a · Cited by 4,744
A Laser Ablation Method for the Synthesis of Crystalline Semiconductor Nanowires
Morales, A. M., & Lieber, C. M. (1998) · Science · doi:10.1126/science.279.5348.208 · Cited by 4,383
Self-citation(1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9 · Cited by 2,526
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Nicolas, J., Mura, S., Brambilla, D., Mackiewicz, N., & Couvreur, P. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35265f · Cited by 1,270
(1995) · Springer eBooks · doi:10.1007/978-1-4615-7858-1 · Cited by 1,039
Chernomordik, L. V., & Kozlov, M. M. (2008) · Nature Structural & Molecular Biology · doi:10.1038/nsmb.1455 · Cited by 1,037
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Self-citationMacroporous Nanowire Nanoelectronic Scaffolds for Synthetic Tissues
Jia Liu, B., Dvir, T., Jin, L., Tsui, J. H., Qing, Q., Suo, Z., Langer, R., Kohane, D. S., Lieber, C. M., & Tian, B. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University) · Cited by 642
Self-citation
Cited by
Syringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Self-citationNext-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
Self-citationSoft and MRI Compatible Neural Electrodes from Carbon Nanotube Fibers
Lu, L., Fu, X., Liew, Y., Zhang, Y., Zhao, S., Xu, Z., Zhao, J., Li, D., Li, Q., Stanley, G. B., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04456 · Cited by 146
Mesh nanoelectronics: seamless integration of electronics with tissues.
Dai, X., Hong, G., Gao, T., & Lieber, C. M. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00547 · Cited by 86
Self-citation
Metadata
- Authors
- Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M.
- Venue
- Nature Nanotechnology
- Published
- 2013-12-15
- Volume
- 9
- Issue
- 2
- Pages
- 142-147
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2148830711
- Cited by
- 257
- References
- 28
- FWCI
- 9.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Free-standing kinked nanowire transistor probes for targeted intracellular recording in three dimensions. https://app.cochat.ai/papers/10.1038/nnano.2013.273
- The paper
- Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M. (2014). Free-standing kinked nanowire transistor probes for targeted intracellular recording in three dimensions. Nature Nanotechnology. https://doi.org/10.1038/nnano.2013.273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.