The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Open accessAbstract
Second-harmonic generation (SHG) microscopy has emerged as a powerful modality for imaging fibrillar collagen in a diverse range of tissues. Because of its underlying physical origin, it is highly sensitive to the collagen fibril/fiber structure, and, importantly, to changes that occur in diseases such as cancer, fibrosis and connective tissue disorders. We discuss how SHG can be used to obtain more structural information on the assembly of collagen in tissues than is possible by other microscopy techniques. We first provide an overview of the state of the art and the physical background of SHG microscopy, and then describe the optical modifications that need to be made to a laser-scanning microscope to enable the measurements. Crucial aspects for biomedical applications are the capabilities and limitations of the different experimental configurations. We estimate that the setup and calibration of the SHG instrument from its component parts will require 2-4 weeks, depending on the level of the user's experience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“second harmonic generation (SHG) microscopy has emerged as a label-free imaging modality capable of visualizing collagen-rich structures within intact spheroids [259,260].”
From Modeling Tumor Microenvironment Complexity In Vitro: Spheroids as Physiologically Relevant Tumor Models and Strategies for Their Analysis (2025) · cites this paper as [259]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Principles of Nonlinear Optics
Shen, Y. R. (1984) · Cited by 5,211
Label-Free Biomedical Imaging with High Sensitivity by Stimulated Raman Scattering Microscopy
Freudiger, C. W., Min, W., Saar, B. G., Lü, S., Holtom, G. R., He, C., Tsai, J. C.-S., Kang, J. X., & Xie, X. S. (2008) · Science · doi:10.1126/science.1165758 · Cited by 2,244
Collagen reorganization at the tumor-stromal interface facilitates local invasion
Provenzano, P. P., Eliceiri, K. W., Campbell, J. M., Inman, D. R., White, J. G., & Keely, P. J. (2006) · BMC Medicine · doi:10.1186/1741-7015-4-38 · Cited by 1,804
Zipfel, W. R., Williams, R. M., Christie, R. H., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,712
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Self-citationAligned Collagen Is a Prognostic Signature for Survival in Human Breast Carcinoma
Conklin, M. W., Eickhoff, J. C., Riching, K. M., Pehlke, C. A., Eliceiri, K. W., Provenzano, P. P., Friedl, A., & Keely, P. J. (2011) · American Journal Of Pathology · doi:10.1016/j.ajpath.2010.11.076 · Cited by 1,321
Campagnola, P. J., Millard, A. C., Terasaki, M., Hoppe, P. E., Malone, C. J., & Mohler, W. A. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75414-3 · Cited by 922
Self-citationZoumi, A., Yeh, A. T., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 872
Interpreting Second-Harmonic Generation Images of Collagen I Fibrils
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2004) · Biophysical Journal · doi:10.1529/biophysj.104.047308 · Cited by 847
Building Collagen Molecules, Fibrils, and Suprafibrillar Structures
HULMES, D. J. S. (2002) · Journal of Structural Biology · doi:10.1006/jsbi.2002.4450 · Cited by 591
Carbocyanine dye orientation in red cell membrane studied by microscopic fluorescence polarization
Axelrod, D. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85271-6 · Cited by 532
Characterization of the Myosin-Based Source for Second-Harmonic Generation from Muscle Sarcomeres
Plotnikov, S. V., Millard, A. C., Campagnola, P. J., & Mohler, W. A. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.071555 · Cited by 444
Self-citation3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
Second Harmonic Generation Imaging Microscopy: Applications to Diseases Diagnostics
Campagnola, P. J. (2011) · Analytical Chemistry · doi:10.1021/ac1032325 · Cited by 412
Self-citationPolarization coherent anti-Stokes Raman scattering microscopy
Cheng, J., Book, L. D., & Xie, X. S. (2001) · Optics Letters · doi:10.1364/ol.26.001341 · Cited by 402
Dynamics of transient pores in stretched vesicles
Sandre, O., Moreaux, L. C., & Brochard‐Wyart, F. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.19.10591 · Cited by 391
Noninvasive Assessment of Collagen Gel Microstructure and Mechanics Using Multiphoton Microscopy
Raub, C. B., Suresh, V., Krasieva, T. B., Lyubovitsky, J. G., Mih, J. D., Putnam, A. J., Tromberg, B. J., & George, S. C. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.097998 · Cited by 374
3D microscopy of transparent objects using third‐harmonic generation
Müller, Squier, Wilson, & Brakenhoff (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00399.x · Cited by 309
Second harmonic generation imaging of collagen fibrils in cornea and sclera
Han, M., Giese, G., & Bille, J. F. (2005) · Optics Express · doi:10.1364/opex.13.005791 · Cited by 293
Second harmonic imaging and scoring of collagen in fibrotic tissues
Strupler, M., Pena, A., Hernest, M., Tharaux, P., Martin, J. L., Beaurepaire, E., & Schanne‐Klein, M. (2007) · Optics Express · doi:10.1364/oe.15.004054 · Cited by 274
Nadiarnykh, O., LaComb, R. B., BREWER, M. A., & Campagnola, P. J. (2010) · BMC Cancer · doi:10.1186/1471-2407-10-94 · Cited by 265
Self-citationDombeck, D. A., Kasischke, K. A., Vishwasrao, H. D., Ingelsson, M., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0731953100 · Cited by 263
Dimitrow, E., Ziemer, M., Koehler, M. J., Norgauer, J., König, K., Elsner, P. U., & Kaatz, M. (2009) · Journal of Investigative Dermatology · doi:10.1038/jid.2008.439 · Cited by 243
Second harmonic generation microscopy: principles and applications to disease diagnosis
Campagnola, P. J., & Dong, C. ‐. (2009) · Laser & Photonics Review · doi:10.1002/lpor.200910024 · Cited by 229
Self-citationPolarization-dependent optical second-harmonic imaging of rat-tail tendon
Stoller, P. C., Kim, B., Rubenchik, A. M., Reiser, K. M., & da Silva, L. B. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1431967 · Cited by 224
Coherent Scattering in Multi-Harmonic Light Microscopy
Moreaux, L. C., Sandre, O., Charpak, S., Blanchard-Desce, M. H., & Mertz, J. C. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76129-2 · Cited by 222
Lin, S., Wu, R.-J., Tan, H., Lo, W., Lin, W., Young, T., Hsu, C., Chen, J., Jee, S., & Dong, C. (2005) · Optics Letters · doi:10.1364/ol.30.002275 · Cited by 215
Practical limits of resolution in confocal and non‐linear microscopy
Cox, G. C., & Sheppard, C. J. R. (2003) · Microscopy Research and Technique · doi:10.1002/jemt.10423 · Cited by 202
Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging
Lin, S., Jee, S., Kuo, C.-J., Wu, R.-J., Lin, W., Chen, J., Liao, Y., Hsu, C., Tsai, T., Chen, Y., et al. (2006) · Optics Letters · doi:10.1364/ol.31.002756 · Cited by 185
Imaging membrane potential in dendritic spines
Nuriya, M., Jiang, J., Nemet, B. A., Eisenthal, K. B., & Yuste, R. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0510092103 · Cited by 182
Chu, S., Chen, S.-Y., Chern, G.-W., Tsai, T.-H., Chen, Y., Lin, B.-L., & Sun, C. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.034595 · Cited by 177
The Collagen Fibril: The Almost Crystalline Structure
Prockop, D. J., & Fertala, A. (1998) · Journal of Structural Biology · doi:10.1006/jsbi.1998.3976 · Cited by 176
Yeh, A. T., Nassif, N. A., Zoumi, A., & Tromberg, B. J. (2002) · Optics Letters · doi:10.1364/ol.27.002082 · Cited by 170
Le, T. T., Langohr, I. M., Locker, M. J., Sturek, M. S., & Cheng, J. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2795437 · Cited by 168
LaComb, R. B., Nadiarnykh, O., Townsend, S. S., & Campagnola, P. J. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.10.040 · Cited by 166
Self-citationOptical Recording of Action Potentials with Second-Harmonic Generation Microscopy
Dombeck, D. A., Blanchard-Desce, M. H., & Webb, W. W. (2004) · Journal of Neuroscience · doi:10.1523/jneurosci.4840-03.2004 · Cited by 166
Second-harmonic generation by focused excitation of inhomogeneously distributed scatterers
Mertz, J. C., & Moreaux, L. C. (2001) · Optics Communications · doi:10.1016/s0030-4018(01)01403-1 · Cited by 159
Drexler, W., Stamper, D. L., Jesser, C. A., Li, X. D., Pitris, C., Saunders, K., MARTIN, S. D., Lodge, M. B., Fujimoto, J. G., & Brezinski, M. E. (2001) · PubMed · Cited by 145
Simultaneous imaging of GFP, CFP and collagen in tumors in vivo using multiphoton microscopy
Segall Jeffrey, E., Philippar, U., Wyckoff, J. B., Sahai, E. A., Gertler, F. B., & Condeelis, J. S. (2005) · DOAJ (DOAJ: Directory of Open Access Journals) · doi:10.1186/1472-6750-5-14 · Cited by 142
Sun, W., Chang, S., Tai, D., Tan, N., Xiao, G., Tang, H., & Yu, H. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041159 · Cited by 140
Endogenous Optical Biomarkers of Ovarian Cancer Evaluated with Multiphoton Microscopy
Kirkpatrick, N. D., BREWER, M. A., & Utzinger, U. (2007) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-07-0009 · Cited by 140
Probing myosin structural conformation in vivo by second-harmonic generation microscopy
Nucciotti, V., Stringari, C., Sacconi, L., Vanzi, F., Fusi, L., Linari, M., Piazzesi, G., Lombardi, V., & Pavone, F. S. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0914782107 · Cited by 137
Rocha‐Mendoza, I., Yankelevich, D. R., Wang, M., Reiser, K. M., Frank, C. W., & Knoesen, A. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.111047 · Cited by 130
LaComb, R. B., Nadiarnykh, O., & Campagnola, P. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.114405 · Cited by 129
Self-citationIn VivoVirtual Biopsy of Human Skin by Using Noninvasive Higher Harmonic Generation Microscopy
Chen, S., Chen, S., Wu, H.-Y., Lee, W., Liao, Y., & Sun, C. (2009) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2009.2031987 · Cited by 122
Polarization-resolved Second Harmonic microscopy in anisotropic thick tissues
Gusachenko, I., Latour, G., & Schanne‐Klein, M. (2010) · Optics Express · doi:10.1364/oe.18.019339 · Cited by 121
Mansfield, J., Winlove, C. P., Moger, J., & Matcher, S. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2950318 · Cited by 119
Deniset‐Besseau, A., Duboisset, J., Bénichou, E., Hache, F., Brevet, P., & Schanne‐Klein, M. (2009) · The Journal of Physical Chemistry B · doi:10.1021/jp9046837 · Cited by 117
Multidimensional non-linear laser imaging of Basal Cell Carcinoma
Cicchi, R., Massi, D., Sestini, S., Carli, P., GIORGI, V. D., Lotti, T., & Pavone, F. S. (2007) · Optics Express · doi:10.1364/oe.15.010135 · Cited by 104
Nonscalar elastic light scattering from continuous random media in the Born approximation
Rogers, J. D., Capoglu, I., & Backman, V. (2009) · Optics Letters · doi:10.1364/ol.34.001891 · Cited by 102
Kwon, G. P., Schroeder, J., Amar, M. J., Remaley, A. T., & Balaban, R. S. (2008) · Circulation · doi:10.1161/circulationaha.107.754614 · Cited by 101
Chiroptical Effects in the Second Harmonic Signal of Collagens I and IV
Pena, A., Boulesteix, T., Dartigalongue, T., & Schanne‐Klein, M. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0520969 · Cited by 101
Determination of Collagen Nanostructure from Second-Order Susceptibility Tensor Analysis
Su, P.-J., Chen, W., Chen, Y., & Dong, C. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.02.015 · Cited by 99
Second harmonic generation imaging microscopy studies of osteogenesis imperfecta
Nadiarnykh, O., Plotnikov, S. V., Mohler, W. A., Kalajzić, I., Redford-Badwal, D. A., & Campagnola, P. J. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2799538 · Cited by 93
Self-citationAjeti, V., Nadiarnykh, O., Ponik, S. M., Keely, P. J., Eliceiri, K. W., & Campagnola, P. J. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002307 · Cited by 92
Self-citationErikson, A., Örtegren, J., Hompland, T., Davies, C. D. L., & Lindgren, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2772311 · Cited by 91
Effects of axial field components on second harmonic generation microscopy
Yew, E. Y. S., & Sheppard, C. J. R. (2006) · Optics Express · doi:10.1364/oe.14.001167 · Cited by 82
Nadiarnykh, O., & Campagnola, P. J. (2009) · Optics Express · doi:10.1364/oe.17.005794 · Cited by 77
Self-citationSchenke‐Layland, K., Xie, J., Angelis, E., STARCHER, B. C., Wu, K., Riemann, I., MacLellan, W. R., & Hamm‐Alvarez, S. F. (2007) · Matrix Biology · doi:10.1016/j.matbio.2007.07.005 · Cited by 74
LaComb, R. B., Nadiarnykh, O., Carey, S. P., & Campagnola, P. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2907207 · Cited by 70
Self-citationA two-photon and second-harmonic microscope
Nikolenko, V., Nemet, B. A., & Yuste, R. (2003) · Methods · doi:10.1016/s1046-2023(03)00003-3 · Cited by 69
Quantitative second harmonic generation imaging of cartilage damage
Brockbank, K. G. M., MacLellan, W. R., Xie, J., Hamm‐Alvarez, S. F., Chen, Z. Z., & Schenke‐Layland, K. (2008) · Cell and Tissue Banking · doi:10.1007/s10561-008-9070-7 · Cited by 64
Millard, A. C., Jin, L., Lewis, A., & Loew, L. M. (2003) · Optics Letters · doi:10.1364/ol.28.001221 · Cited by 58
Lilledahl, M. B., Pierce, D. M., Ricken, T., Holzapfel, G. A., & Davies, C. D. L. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2139222 · Cited by 57
Signal epidetection in third-harmonic generation microscopy of turbid media
Débarre, D., Olivier, N., & Beaurepaire, E. (2007) · Optics Express · doi:10.1364/oe.15.008913 · Cited by 57
Automated quantification and reconstruction of collagen matrix from 3D confocal datasets
Wu, J., Rajwa, B. P., Filmer, D. L., Hoffmann, C. M., Yuan, B., Chiang, C., Sturgis, J., & Robinson, J. P. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01191.x · Cited by 55
Optical clearing in transcutaneous Raman spectroscopy of murine cortical bone tissue
Schulmerich, M. V., Cole, J. H., Dooley, K. A., Morris, M. D., Kreider, J. M., & Goldstein, S. A. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2892687 · Cited by 46
Liu, B., Harman, M., Giattina, S. D., Stamper, D. L., Demakis, C., Chilek, M., Raby, S., & Brezinski, M. E. (2006) · Applied Optics · doi:10.1364/ao.45.004464 · Cited by 37
Intact corneal stroma visualization of GFP mouse revealed by multiphoton imaging
Lo, W., Teng, S., Tan, H., Kim, K. H., Chen, H., Lee, M., Chen, Y., So, P. T. C., & Dong, C. (2006) · Microscopy Research and Technique · doi:10.1002/jemt.20373 · Cited by 37
Cited by
Sorted by citations
Datta, R., Heaster, T. M., Sharick, J. T., Gillette, A. A., & Skala, M. C. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.7.071203 · Cited by 886
Bredfeldt, J. S., Liu, Y., Pehlke, C. A., Conklin, M. W., Szulczewski, J. M., Inman, D. R., Keely, P. J., Nowak, R. D., Mackie, T., & Eliceiri, K. W. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016007 · Cited by 413
Collot, M., Fam, K. T., Ashokkumar, P., Faklaris, O., Galli, T., Danglot, L., & Klymchenko, A. S. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b12817 · Cited by 409
Marangoni, R. G., Korman, B. D., Wei, J., Wood, T. A., Graham, L. V., Whitfield, M. L., Scherer, P. E., Tourtellotte, W. G., & Varga, J. (2015) · Arthritis & Rheumatology · doi:10.1002/art.38990 · Cited by 337
Collagen: quantification, biomechanics and role of minor subtypes in cartilage
Bielajew, B. J., Hu, J. C. Y., & Athanasiou, K. A. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0213-1 · Cited by 325
Metadata
- Authors
- Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J.
- Affiliations
- University of Wisconsin–Madison (US)
- National Institutes of Health (US)
- Corresponding author
- Campagnola, Paul J
- Venue
- Nature Protocols
- Published
- 2012-03-08
- Volume
- 7
- Issue
- 4
- Pages
- 654-669
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- PMC
- PMC4337962
- OpenAlex
- W1996841581
- Cited by
- 985
- References
- 69
- Citations by year
- 2026: 67 · 2025: 81 · 2024: 91 · 2023: 81 · 2022: 80 · 2021: 93 · 2020: 101 · 2019: 73 · 2018: 82 · 2017: 71 · 2016: 51 · 2015: 44 · 2014: 38 · 2013: 23 · 2012: 7
- FWCI
- 16.39
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Protocols (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Cancer Institute (R01CA136590, CA136590)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
- Keywords
- second harmonic generation microscopy, collagen fibrils, collagen fibril structure, collagen self-assembly, instrument calibration, connective tissue diseases, fibrosis, cancer, nonlinear optical imaging
- MeSH terms
- Calibration, Collagen, Microscopy, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review