CoChat

A MEMS ultrasound stimulation system for modulation of neural circuits with high spatial resolution in vitro

Open access
Lee, Jungpyo, Ko, Kyungmin, Shin, Hyogeun, Oh, Soo-Jin, Lee, C. Justin, Chou, Namsun, Choi, Nakwon, Tack Oh, Min, Chul Lee, Byung, Chan Jun, Seong, Cho, Il-Joo · 2019 · Microsystems & Nanoengineering
Cited by 44

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Neuromodulation by ultrasound has recently received attention due to its noninvasive stimulation capability for treating brain diseases. Although there have been several studies related to ultrasonic neuromodulation, these studies have suffered from poor spatial resolution of the ultrasound and low repeatability with a fixed condition caused by conventional and commercialized ultrasound transducers. In addition, the underlying physics and mechanisms of ultrasonic neuromodulation are still unknown. To determine these mechanisms and accurately modulate neural circuits, researchers must have a precisely controllable ultrasound transducer to conduct experiments at the cellular level. Herein, we introduce a new MEMS ultrasound stimulation system for modulating neurons or brain slices with high spatial resolution. The piezoelectric micromachined ultrasonic transducers (pMUTs) with small membranes (sub-mm membranes) generate enough power to stimulate neurons and enable precise modulation of neural circuits. We designed the ultrasound transducer as an array structure to enable localized modulation in the target region. In addition, we integrated a cell culture chamber with the system to make it compatible with conventional cell-based experiments, such as in vitro cell cultures and brain slices. In this work, we successfully demonstrated the functionality of the system by showing that the number of responding cells is proportional to the acoustic intensity of the applied ultrasound. We also demonstrated localized stimulation capability with high spatial resolution by conducting experiments in which cocultured cells responded only around a working transducer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41378-019-0070-5

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 44

Metadata

Authors
Lee, J., Ko, K., Shin, H., Oh, S.-J., Lee, C. J., Chou, N., Choi, N., Tack Oh, M., Chul Lee, B., Chan Jun, S., & Cho, I.-J.
Venue
Microsystems & Nanoengineering
Published
2019-07-15
Volume
5
Issue
1
Pages
28-28
ISSN
2055-7434 (ISSN-L)
OpenAlex
W2956325589
Cited by
44
References
3
FWCI
2.09
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A MEMS ultrasound stimulation system for modulation of neural circuits with high spatial resolution in vitro. https://app.cochat.ai/papers/10.1038/s41378-019-0070-5
The paper
Lee, J., Ko, K., Shin, H., Oh, S.-J., Lee, C. J., Chou, N., Choi, N., Tack Oh, M., Chul Lee, B., Chan Jun, S., & Cho, I.-J. (2019). A MEMS ultrasound stimulation system for modulation of neural circuits with high spatial resolution in vitro. Microsystems & Nanoengineering. https://doi.org/10.1038/s41378-019-0070-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.