Moisture-resistant, stretchable NOx gas sensors based on laser-induced graphene for environmental monitoring and breath analysis
Open accessThe DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
The accurate, continuous analysis of healthcare-relevant gases such as nitrogen oxides (NO x) in a humid environment remains elusive for low-cost, stretchable gas sensing devices. This study presents the design and demonstration of a moisture-resistant, stretchable NO x gas sensor based on laser-induced graphene (LIG). Sandwiched between a soft elastomeric substrate and a moisture-resistant semipermeable encapsulant, the LIG sensing and electrode layer is first optimized by tuning laser processing parameters such as power, image density, and defocus distance. The gas sensor, using a needlelike LIG prepared with optimal laser processing parameters, exhibits a large response of 4.18‰ ppm−1 to NO and 6.66‰ ppm−1 to NO 2, an ultralow detection limit of 8.3 ppb to NO and 4.0 ppb to NO 2, fast response/recovery, and excellent selectivity. The design of a stretchable serpentine structure in the LIG electrode and strain isolation from the stiff island allows the gas sensor to be stretched by 30%. Combined with a moisture-resistant property against a relative humidity of 90%, the reported gas sensor has further been demonstrated to monitor the personal local environment during different times of the day and analyze human breath samples to classify patients with respiratory diseases from healthy volunteers. Moisture-resistant, stretchable NO x gas sensors can expand the capability of wearable devices to detect biomarkers from humans and exposed environments for early disease diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Thermal properties of graphene and nanostructured carbon materials
Balandin, A. A. (2011) · Nature Materials · doi:10.1038/nmat3064 · Cited by 6,244
Environmental and Health Impacts of Air Pollution: A Review
Manisalidis, I., Stavropoulou, E., Stavropoulos, A., & Bezirtzoglou, E. (2020) · Frontiers in Public Health · doi:10.3389/fpubh.2020.00014 · Cited by 5,269
Currie, L. A. (1995) · Pure and Applied Chemistry · doi:10.1351/pac199567101699 · Cited by 1,703
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Practical Chemical Sensors from Chemically Derived Graphene
Fowler, J. D., Allen, M. J., Tung, V. C., Yang, Y., Kaner, R. B., & Weiller, B. H. (2009) · ACS Nano · doi:10.1021/nn800593m · Cited by 1,447
Yuan, W., & Shi, G. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta11774j · Cited by 1,073
Nitric oxide in health and disease of the respiratory system
Ricciardolo, F. L. M., Sterk, P. J., Gaston, B., & Folkerts, G. (2004) · Physiological Reviews · doi:10.1152/physrev.00034.2003 · Cited by 903
Ye, R., James, D. K., & Tour, J. M. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00084 · Cited by 795
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Cited by
Zhang, H., Zhang, D., Zhang, B., Wang, D., & Tang, M. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c14863 · Cited by 182
Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors
Wang, Y., & Zhou, Y. (2022) · Materials · doi:10.3390/ma15248728 · Cited by 180
Metadata
- Authors
- Yang, L., Zheng, G., Cao, Y., Meng, C., Li, Y., Ji, H., Chen, X., Niu, G., Yan, J., Xue, Y., & Cheng, H.
- Venue
- Microsystems & Nanoengineering
- Published
- 2022-07-08
- Volume
- 8
- Issue
- 1
- Pages
- 78-78
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W4284897849
- Cited by
- 194
- References
- 65
- FWCI
- 10.64
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.