A highly sensitive and moisture-resistant gas sensor for diabetes diagnosis with Pt@In2O3 nanowires and a molecular sieve for protection
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Sensitive and selective detection of acetone in human exhaled breath plays an important role in the diagnosis of diabetes. However, obtaining a reliable response to ppb levels of acetone and avoiding cross-sensitivity due to the large amount of moisture in exhaled breath are still great challenges. In this work, a type of acetone sensor with ultrahigh sensitivity and moisture resistance is reported. Electrospun In2O3 nanowires with a controllable Pt core (Pt@In2O3 core-shell nanowires) are designed and prepared as sensitive layers. A mesoporous silica molecular sieve is further integrated as the moisture filter layer. The Pt@In2O3 core-shell nanowire-based sensor exhibits a highly improved response compared with a sensor based on pure In2O3 nanowires due to the probable increase in surface resistance and the introduction of p–n junctions after rational design of the structure. In addition, a good performance in terms of the fast dynamic process, selectivity and long-term stability is also achieved, and the detection limit can be as low as 10 ppb, which is much lower than the concentration level of 1.8 ppm in the exhaled breath of diabetic patients. The influence of the large amount of moisture is greatly weakened by using the molecular sieve as a moisture filter layer, leading to much improved sensitivity in clinical sample detection among healthy and diabetic patients. Based on the optimized composite structure of the Pt@In2O3 core-shell nanowire sensor and moisture filter layer, a simple portable sensing prototype is successfully fabricated. The reported Pt@In2O3 core-shell nanowires and the acetone sensing approach open up a new opportunity for a simple, inexpensive, and noninvasive diagnosis of diabetes. Portable sensors containing metallic nanowires and moisture-absorbing desiccants can spot critical levels of a diabetes biomarker in human breath. Recent studies show that an acetone concentration of 1.8 parts per million in exhaled breath implies high diabetes risk. Lin Xu and co-workers from Jilin University, Changchun, China, report a one-step preparation of acetone-sensitive nanomaterials. By forcing reagents through thin needles, the team produced iridium oxide nanowires with a solid core of pure platinum, a combination that makes the nanowires’ surface unusually sensitive to resistance changes due to foreign particles. At specific operating temperatures, the nanowires swiftly detected acetone absorption at levels as low as 10 parts per billion. A prototype containing the nanowires and a water-trapping film of molecular sieves made it possible to distinguish healthy people from those with diabetes simply by collecting breath samples. In this work, electrospun In2O3 nanowires with controllable Pt core were designed and prepared as an ultra-sensitive layer with good electron transmission ability as well as high surface area, and then SBA-15 molecular sieve was further integrated as a moisture filter layer. The as-design device was successfully used to detect trace acetone biomarker in exhaled breath, which could accurately distinguish the health people from diabetes in clinical samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Semiconductor-mediated photodegradation of pollutants under visible-light irradiation
Chen, C., Ma, W., & Zhao, J. (2010) · Chemical Society Reviews · doi:10.1039/b921692h · Cited by 2,214
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
High‐Temperature‐Stable Catalysts by Hollow Sphere Encapsulation
Arnal, P. M., Comotti, M., & Schüth, F. (2006) · Angewandte Chemie · doi:10.1002/ange.200603507 · Cited by 679
High‐Temperature‐Stable Catalysts by Hollow Sphere Encapsulation
Arnal, P. M., Comotti, M., & Schüth, F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603507 · Cited by 654
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Parkes, J. L., Slatin, S. L., Pardo, S., & Ginsberg, B. H. (2000) · Diabetes Care · doi:10.2337/diacare.23.8.1143 · Cited by 620
Temperature modulation in semiconductor gas sensing
Lee, A. (1999) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(99)00241-5 · Cited by 525
Achieving high specific charge capacitances in Fe3O4/reduced graphene oxide nanocomposites
Shi, W., Zhu, J., Sim, D. H., Tay, Y. Y., Lu, Z., Zhang, X., Sharma, Y., Srinivasan, M., Zhang, H., Hng, H. H., et al. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm03175e · Cited by 470
Cited by
Advances in Noble Metal-Decorated Metal Oxide Nanomaterials for Chemiresistive Gas Sensors: Overview
Zhu, L.-Y., Ou, L.-X., Mao, L.-W., Wu, X.-Y., Liu, Y.-P., & Lu, H.-L. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01047-z · Cited by 553
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Selectivity in Chemiresistive Gas Sensors: Strategies and Challenges
Bulemo, P. M., Kim, D.-H., Shin, H., Cho, H.-J., Koo, W.-T., Choi, S.-J., Park, C., Ahn, J., Güntner, A. T., Penner, R. M., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00592 · Cited by 418
Zhou, T., & Zhang, T. (2021) · Small Methods · doi:10.1002/smtd.202100515 · Cited by 350
Nyabadza, A., McCarthy, É., Makhesana, M., Heidarinassab, S., Plouze, A., Vazquez, M., & Brabazon, D. (2023) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2023.103010 · Cited by 318
Nanostructured Metal Oxide-Based Acetone Gas Sensors: A Review
Amiri, V., Roshan, H., Mirzaei, A., Neri, G., & Ayesh, A. I. (2020) · Sensors · doi:10.3390/s20113096 · Cited by 287
Das, S., Mojumder, S., Saha, D., & Pal, M. (2022) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2021.131066 · Cited by 229
Tang, H., Sacco, L. N., Vollebregt, S., Ye, H., Fan, X., & Zhang, G. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta08190f · Cited by 223
Recent Progress on Anti-Humidity Strategies of Chemiresistive Gas Sensors
Wang, Y., & Zhou, Y. (2022) · Materials · doi:10.3390/ma15248728 · Cited by 180
Core@shell nanomaterials based sensing devices: A review
Kalambate, P. K., Dhanjai, Huang, Z., Li, Y., Shen, Y., Xie, M., Huang, Y., & Srivastava, A. K. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.04.002 · Cited by 164
Xu, Y., Zheng, L., Yang, C., Zheng, W., Liu, X., & Zhang, J. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.127846 · Cited by 162
Down to ppb level NO2 detection by ZnO/rGO heterojunction based chemiresistive sensors
Cao, P., Cai, Y., Pawar, D., Navale, S. T., Rao, C. N., Han, S., Xu, W., Fang, M., Liu, X., Zeng, Y., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.125491 · Cited by 159
Self-citationNew dimensions of electrospun nanofiber material designs for biotechnological uses
Kamaraj, M., Moghimi, N., Chen, J., Morales, R., Chen, S., Khademhosseini, A., & John, J. V. (2024) · Trends in Biotechnology · doi:10.1016/j.tibtech.2023.11.008 · Cited by 44
Metadata
- Authors
- Liu, W., Xu, L., Sheng, K., Zhou, X., Dong, B., Lu, G., & Song, H.
- Venue
- NPG Asia Materials
- Published
- 2018-04
- Volume
- 10
- Issue
- 4
- Pages
- 293-308
- ISSN
- 1884-4049 (ISSN-L)
- 1884-4057
- OpenAlex
- W2801247897
- Cited by
- 182
- References
- 41
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.