High-sensitivity ion detection at low voltages with current-driven organic electrochemical transistors
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Ions dissolved in aqueous media play a fundamental role in plants, animals, and humans. Therefore, the in situ quantification of the ion concentration in aqueous media is gathering relevant interest in several fields including biomedical diagnostics, environmental monitoring, healthcare products, water and food test and control, agriculture industry and security. The fundamental limitation of the state-of-art transistor-based approaches is the intrinsic trade-off between sensitivity, ion concentration range and operating voltage. Here we show a current-driven configuration based on organic electrochemical transistors that overcomes this fundamental limit. The measured ion sensitivity exceeds by one order of magnitude the Nernst limit at an operating voltage of few hundred millivolts. The ion sensitivity normalized to the supply voltage is larger than 1200 mV V−1 dec−1, which is the largest value ever reported for ion-sensitive transistors. The proposed approach is general and can be extended to any transistor technology, thus opening opportunities for high-performance bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Patra, P. P., Chikkaraddy, R., Tripathi, R. P. N., Dasgupta, A., & Kumar, G. V. P. (2014) · Nature Communications · doi:10.1038/ncomms5357 · Cited by 1,635
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Steady‐State and Transient Behavior of Organic Electrochemical Transistors
Bernards, D. A., & Malliaras, G. G. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601239 · Cited by 997
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
High transconductance organic electrochemical transistors
Khodagholy, D., Rivnay, J., Sessolo, M., Gurfinkel, M., Leleux, P., Jimison, L. H., Stavrinidou, E., Herve, T., Sanaur, S., Owens, R. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms3133 · Cited by 862
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Chloride impermeability in cystic fibrosis
Quinton, P. M. (1983) · Nature · doi:10.1038/301421a0 · Cited by 767 · cited 5×
“(2), the ion concentration sensitivity can be calculated as follows:”
InfluentialHigh-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 728
The Rise of Organic Bioelectronics
Rivnay, J., Owens, R. M., & Malliaras, G. G. (2014) · Chemistry of Materials · doi:10.1021/cm4022003 · Cited by 713
Zhang, J. X., Dai, J., Chow, C. K., Sun, C., Lo, V. C., & Chan, H. L. W. (2008) · Applied Physics Letters · Cited by 591
Organic Bioelectronics: Bridging the Signaling Gap between Biology and Technology
Simon, D. T., Gabrielsson, E. O., Tybrandt, K., & Berggren, M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00146 · Cited by 568
A 13.56-MHz RFID System Based on Organic Transponders
Cantatore, E., Geuns, T. C. T., Gelinck, G. H., van Veenendaal, E., Gruijthuijsen, A. F. A., Schrijnemakers, L., Drews, S., & de Leeuw, D. M. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886556 · Cited by 504
New insights into cystic fibrosis: molecular switches that regulate CFTR
Guggino, W. B., & Stanton, B. A. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1949 · Cited by 432
Knopfmacher, O., Hammock, M. L., Appleton, A. L., Schwartz, G., Mei, J., Lei, T., Pei, J., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms3954 · Cited by 415
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Organic Electrochemical Transistors with Maximum Transconductance at Zero Gate Bias
Rivnay, J., Leleux, P., Sessolo, M., Khodagholy, D., Hervé, T., Fiocchi, M., & Malliaras, G. G. (2013) · Advanced Materials · doi:10.1002/adma.201303080 · Cited by 300
Ion-Sensitive Properties of Organic Electrochemical Transistors
Lin, P., Yan, F., & Chan, H. L. W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100154e · Cited by 294
Recent trends in potentiometric sensor arrays—A review
Bratov, A., Abramova, N., & Ipatov, A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.08.035 · Cited by 257
Ion‐Selective Organic Electrochemical Transistors
Sessolo, M., Rivnay, J., Bandiello, E., Malliaras, G. G., & Bolink, H. J. (2014) · Advanced Materials · doi:10.1002/adma.201400731 · Cited by 206
Logic gates based on ion transistors
Tybrandt, K., Forchheimer, R., & Berggren, M. (2012) · Nature Communications · doi:10.1038/ncomms1869 · Cited by 191
Dual‐Gate Thin‐Film Transistors, Integrated Circuits and Sensors
Spijkman, M., Myny, K., Smits, E. C. P., Heremans, P., Blom, P. W. M., & de Leeuw, D. M. (2011) · Advanced Materials · doi:10.1002/adma.201101493 · Cited by 176
Self-citationOrganic Electrochemical Transistors for Clinical Applications
Leleux, P., Rivnay, J., Lonjaret, T., Badier, J., Bénar, C., Hervé, T., Chauvel, P., & Malliaras, G. G. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400356 · Cited by 163
Voltage Amplifier Based on Organic Electrochemical Transistor
Braendlein, M., Lonjaret, T., Leleux, P., Badier, J., & Malliaras, G. G. (2016) · Advanced Science · doi:10.1002/advs.201600247 · Cited by 161
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
Self-citationElectrolyte‐Gated Organic Field‐Effect Transistor for Selective Reversible Ion Detection
Schmoltner, K., Kofler, J., Klug, A., & List, E. J. W. (2013) · Advanced Materials · doi:10.1002/adma.201303281 · Cited by 137
Beyond the Nernst-limit with dual-gate ZnO ion-sensitive field-effect transistors
Spijkman, M., Smits, E. C. P., Cillessen, J. F. M., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2011) · Applied Physics Letters · doi:10.1063/1.3546169 · Cited by 135
Self-citationElectrolyte-gated organic field-effect transistors for sensing applications
Buth, F., Kumar, D., Stutzmann, M., & Garrido, J. A. (2011) · Applied Physics Letters · doi:10.1063/1.3581882 · Cited by 113
High mobility graphene ion-sensitive field-effect transistors by noncovalent functionalization
Fu, W., Nef, C., Tarasov, A., Wipf, M., Stoop, R. L., Knopfmacher, O., Weiss, M., Calame, M., & Schönenberger, C. (2013) · Nanoscale · doi:10.1039/c3nr03940d · Cited by 105
Serum Electrolytes in Ironman Triathletes with Exercise-Associated Muscle Cramping
SULZER, N. U., SCHWELLNUS, M. P., & NOAKES, T. D. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000169723.79558.cf · Cited by 103 · cited 1×
“(3) shows that the ion concentration sensitivity depends on the OECT parameters sensitivity, viz.”
Gholizadeh, A., Voiry, D., Weisel, C. P., Gow, A. J., Laumbach, R. J., Kipen, H. M., Chhowalla, M., & Javanmard, M. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.22 · Cited by 85
Kumar, N. C., Kumar, J., & Panda, S. (2016) · IEEE Electron Device Letters · doi:10.1109/led.2016.2536359 · Cited by 81
Dynamic changes in saliva after acute mental stress
Naumova, E. A., Sandulescu, T., Bochnig, C., Khatib, P. A., Lee, W., Zimmer, S., & Arnold, W. H. (2014) · Scientific Reports · doi:10.1038/srep04884 · Cited by 58
Ji, T., Rai, P., Jung, S., & Varadan, V. K. (2008) · Applied Physics Letters · doi:10.1063/1.2936296 · Cited by 52
Measurement of extracellular pH, K+, and lactate in ischemic heart
Marzouk, S. A. M., Buck, R. P., Dunlap, L. A., Johnson, T. A., & Cascio, W. E. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00220-8 · Cited by 48
Electrolyte-Sensing Transistor Decals Enabled by Ultrathin Microbial Nanocellulose
Yuen, J. D., Walper, S. A., Melde, B. J., Daniele, M. A.-A., & Stenger, D. A. (2017) · Scientific Reports · doi:10.1038/srep40867 · Cited by 41
Patterns of sodium and potassium excretion and blood pressure in the African Diaspora
Tayo, B. O., Luke, A., McKenzie, C. A., Kramer, H., Cao, G., Durazo-Arvizú, R., Forrester, T., Adeyemo, A., & Cooper, R. (2011) · Journal of Human Hypertension · doi:10.1038/jhh.2011.39 · Cited by 37
Zinc oxide ion-sensitive field-effect transistors and biosensors
Yano, M., Koike, K., Mukai, K., Onaka, T., Hirofuji, Y., Ogata, K.-I., Omatu, S., Maemoto, T., & Sasa, S. (2014) · physica status solidi (a) · doi:10.1002/pssa.201300589 · Cited by 35
Park, S., Baek, S. H., Lee, S. W., Lee, A., Chin, H. J., Na, K. Y., Kim, D. K., Chae, D., Han, J. S., & Kim, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-02681-5 · Cited by 28
Organic electrochemical transistor immuno-sensor operating at the femto-molar limit of detection
Macchia, E., Ghittorelli, M., Torricelli, F., & Torsi, L. (2017) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2017.7974217 · Cited by 13
Self-citation
Cited by
Skin-Interfaced Wearable Sweat Sensors for Precision Medicine
Min, J., Tu, J., Xu, C., Lukas, H., Shin, S., Yang, Y., Solomon, S. A., Mukasa, D., & Gao, W. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00823 · Cited by 712
An organic electrochemical transistor for multi-modal sensing, memory and processing
Wang, S., Chen, X., Zhao, C., Kong, Y., Lin, B., Wu, Y., Bi, Z., Xuan, Z., Li, T., Li, Y., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-00950-y · Cited by 350
Recent developments in biosensors for healthcare and biomedical applications: A review
Mohankumar, P., Ajayan, J., Mohanraj, T., & Yasodharan, R. (2021) · Measurement · doi:10.1016/j.measurement.2020.108293 · Cited by 266
Romele, P., Gkoupidenis, P., Koutsouras, D. A., Lieberth, K., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F. (2020) · Nature Communications · doi:10.1038/s41467-020-17547-0 · Cited by 170
Self-citation
Metadata
- Authors
- Ghittorelli, M., Lingstedt, L., Romele, P., Crăciun, N. I., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F.
- Venue
- Nature Communications
- Published
- 2018-04-12
- Volume
- 9
- Issue
- 1
- Pages
- 1441-1441
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2797670946
- Cited by
- 163
- References
- 41
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.