Ratiometric nanothermometer in vivo based on triplet sensitized upconversion
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Temperature is an essential factor that counts for living systems where complicated vital activities are usually temperature dependent. In vivo temperature mapping based on non-contact optical approach will be beneficial for revealing the physiological phenomena behind with minimized influence to the organism. Herein, a highly thermal-sensitive upconversion system based on triplet–triplet annihilation (TTA) mechanism is pioneered to indicate body temperature variation sensitively over the physiological temperature range. The temperature-insensitive NaYF 4: Nd nanophosphors with NIR emission was incorporated into the temperature-responsive TTA-upconversion system to serve as an internal calibration unit. Consequently, a ratiometric thermometer capable of accurately monitoring the temperature changes in vivo was developed with high thermal sensitivity (~7.1% K−1) and resolution (~0.1 K).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Upconversion and Anti-Stokes Processes with f and d Ions in Solids
Auzel, F. (2004) · Chemical Reviews · doi:10.1021/cr020357g · Cited by 5,098
Recent advances in the chemistry of lanthanide-doped upconversion nanocrystals
Wang, F., & Liu, X. (2009) · Chemical Society Reviews · doi:10.1039/b809132n · Cited by 3,004
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Upconversion Luminescent Materials: Advances and Applications
Zhou, J., Liu, Q., Feng, W., Sun, Y., & Li, F. (2015) · Chemical Reviews · doi:10.1021/cr400478f · Cited by 2,254
Self-citationLuminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
Brites, C. D. S., Lima, P. P., Silva, N. J. O., Millán, A., Amaral, V. S., Palacio, F., & Carlos, L. D. (2012) · Nanoscale · doi:10.1039/c2nr30663h · Cited by 1,592
Triplet photosensitizers: from molecular design to applications
Zhao, J., Wu, W., Sun, J., & Guo, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35531d · Cited by 1,579
Jaque, D., & Vetrone, F. (2012) · Nanoscale · doi:10.1039/c2nr30764b · Cited by 1,507
Photon upconversion based on sensitized triplet–triplet annihilation
Singh-Rachford, T. N., & Castellano, F. N. (2010) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2010.01.003 · Cited by 1,471
Fluorescence intensity ratio technique for optical fiber point temperature sensing
Wade, S. A., Collins, S. F., & Baxter, G. W. (2003) · Journal of Applied Physics · doi:10.1063/1.1606526 · Cited by 1,307
Relative and absolute determination of fluorescence quantum yields of transparent samples
Würth, C., Grabolle, M., Pauli, J., Spieles, M., & Resch-Genger, U. (2013) · Nature Protocols · doi:10.1038/nprot.2013.087 · Cited by 1,216
Okabe, K., Inada, N., Gota, C., Harada, Y., Funatsu, T., & Uchiyama, S. (2012) · Nature Communications · doi:10.1038/ncomms1714 · Cited by 1,203
Zhu, X., Feng, W., Chang, J., Tan, Y.-W., Li, J., Chen, M., Sun, Y., & Li, F. (2016) · Nature Communications · doi:10.1038/ncomms10437 · Cited by 1,013
Self-citationSomero, G. N. (1995) · Annual Review of Physiology · doi:10.1146/annurev.ph.57.030195.000355 · Cited by 843
Reactive oxygen species and antioxidants in inflammatory diseases
Chapple, I. L. C. (1997) · Journal of Clinical Periodontology · doi:10.1111/j.1600-051x.1997.tb00760.x · Cited by 628
Low-power photon upconversion through triplet–triplet annihilation in polymers
Simon, Y. C., & Weder, C. (2012) · Journal of Materials Chemistry · doi:10.1039/c2jm33654e · Cited by 416
Quantum Dot Nano Thermometers Reveal Heterogeneous Local Thermogenesis in Living Cells
Yang, J.-M., Yang, H., & Lin, L. (2011) · ACS Nano · doi:10.1021/nn201142f · Cited by 416
Robinson, J. T., Hong, G., Liang, Y., Zhang, B., Yaghi, O. K., & Dai, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja303737a · Cited by 412
Subtissue Thermal Sensing Based on Neodymium-Doped LaF3Nanoparticles
Rocha, U., Jacinto da Silva, C., Ferreira Silva, W., Guedes, I., Benayas, A., Martínez Maestro, L., Acosta Elias, M., Bovero, E., van Veggel, F. C. J. M., García Solé, J. A., et al. (2013) · ACS Nano · doi:10.1021/nn304373q · Cited by 382
Carrasco, E., del Rosal, B., Sanz‐Rodríguez, F., de la Fuente, Á. J., Gonzalez, P. H., Rocha, U., Kumar, K. U., Jacinto, C., Solé, J. G., & Jaque, D. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201403653 · Cited by 333
In Vivo Luminescence Nanothermometry: from Materials to Applications
del Rosal, B., Ximendes, E., Rocha, U., & Jaque, D. (2017) · Advanced Optical Materials · doi:10.1002/adom.201600508 · Cited by 331
Unveiling in Vivo Subcutaneous Thermal Dynamics by Infrared Luminescent Nanothermometers
Ximendes, E. C., Santos, W. Q., Rocha, U., Kagola, U. K., Sanz-Rodríguez, F., Fernández, N., Gouveia-Neto, A. D. S., Bravo, D., Domingo, A. M., del Rosal, B., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04611 · Cited by 325
Liu, Q., Yin, B., Yang, T., Yang, Y., Shen, Z., Yao, P., & Li, F. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3104268 · Cited by 297
Self-citationA critique of methods for temperature imaging in single cells
Baffou, G., Rigneault, H., Marguet, D., & Jullien, L. (2014) · Nature Methods · doi:10.1038/nmeth.3073 · Cited by 265
Mackowiak, P. A. (1998) · Archives of Internal Medicine · doi:10.1001/archinte.158.17.1870 · Cited by 254
Singh-Rachford, T. N., Haefele, A., Ziessel, R., & Castellano, F. N. (2008) · Journal of the American Chemical Society · doi:10.1021/ja807056a · Cited by 241
Photon upconversion: from two-photon absorption (TPA) to triplet–triplet annihilation (TTA)
Ye, C., Zhou, L., Wang, X., & Liang, Z. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp07296d · Cited by 213
In Vivo Subcutaneous Thermal Video Recording by Supersensitive Infrared Nanothermometers
Ximendes, E. C., Rocha, U., Sales, T. O., Fernández, N., Sanz‐Rodríguez, F., Martín, I. R., Jacinto, C., & Jaque, D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702249 · Cited by 210
Cerón, E. N., Ortgies, D. H., del Rosal, B., Ren, F., Benayas, A., Vetrone, F., Ma, D., Sanz‐Rodríguez, F., Solé, J. G., Jaque, D., et al. (2015) · Advanced Materials · doi:10.1002/adma.201501014 · Cited by 200
Thermal Imaging of Receptor-Activated Heat Production in Single Cells
Zohar, O., Ikeda, M., Shinagawa, H., Inoue, H., Nakamura, H., Elbaum, D., Alkon, D. L., & Yoshioka, T. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77769-0 · Cited by 183
Recent emergence of photon upconversion based on triplet energy migration in molecular assemblies
Yanai, N., & Kimizuka, N. (2016) · Chemical Communications · doi:10.1039/c6cc00089d · Cited by 168
Fluorescent Nanothermometers for Intracellular Thermal Sensing
Jaque, D., del Rosal, B., Rodríguez, E. M., Maestro, L. M., Haro‐González, P., & García‐Solé, J. (2014) · Nanomedicine · doi:10.2217/nnm.14.59 · Cited by 162
Grand, A. M. D., Lomnes, S. J., Lee, D. S., Pietrzykowski, M., Ohnishi, S., Morgan, T. G., Gogbashian, A., Laurence, R. G., & Frangioni, J. V. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2170579 · Cited by 147
Determining intracellular temperature at single-cell level by a novel thermocouple method
Wang, C., Xu, R., Tian, W., Jiang, X., Cui, Z., Wang, M., Sun, H., Fang, K., & Gu, N. (2011) · Cell Research · doi:10.1038/cr.2011.117 · Cited by 144
Filatov, M. A., Baluschev, S. B., & Landfester, K. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00092d · Cited by 143
Benayas, A., Ren, F., Carrasco, E., Marzal, V., del Rosal, B., Gonfa, B. A., Juarranz, Á., Sanz-Rodríguez, F., Jaque, D., García‐Solé, J., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201502632 · Cited by 141
In vivoautofluorescence in the biological windows: the role of pigmentation
del Rosal, B., Villa, I., Jaque, D., & Sanz-Rodríguez, F. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201500271 · Cited by 130
He, D., Guo, C., Jiang, S., Zhang, N., Duan, C., Yin, M., & Li, T. (2014) · RSC Advances · doi:10.1039/c4ra11771a · Cited by 115
Borisov, S. M., Larndorfer, C., & Klimant, I. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200794 · Cited by 94
In Vivo Ischemia Detection by Luminescent Nanothermometers
Ximendes, E. C., Rocha, U., del Rosal, B., Vaquero, A. S. G., Sanz-Rodríguez, F., Monge, L., Ren, F., Vetrone, F., Ma, D., García‐Solé, J., et al. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201601195 · Cited by 93
Askes, S. H. C., Pomp, W., Hopkins, S. L., Kros, A., Wu, S., Schmidt, T., & Bonnet, S. (2016) · Small · doi:10.1002/smll.201601708 · Cited by 85
Goudarzi, H., & Keivanidis, P. E. (2014) · The Journal of Physical Chemistry C · doi:10.1021/jp5052936 · Cited by 47
Xu, K., Zhao, J., Cui, X., & Ma, J. (2014) · Chemical Communications · doi:10.1039/c4cc09202c · Cited by 40
Cited by
Spotlight on Luminescence Thermometry: Basics, Challenges, and Cutting‐Edge Applications
Brites, C. D. S., Marin, R., Suta, M., Carneiro Neto, A. N., Ximendes, E., Jaque, D., & Carlos, L. D. (2023) · Advanced Materials · doi:10.1002/adma.202302749 · Cited by 464
Standardizing luminescence nanothermometry for biomedical applications
Bednarkiewicz, A., Marciniak, L., Carlos, L. D., & Jaque, D. (2020) · Nanoscale · doi:10.1039/d0nr03568h · Cited by 411
Suo, H., Zhao, X., Zhang, Z., Wang, Y., Sun, J., Jin, M., & Guo, C. (2021) · Laser & Photonics Reviews · doi:10.1002/lpor.202000319 · Cited by 410
Zhu, X., Zhang, J., Liu, J., & Zhang, Y. (2019) · Advanced Science · doi:10.1002/advs.201901358 · Cited by 370
Self-citationSuta, M., & Meijerink, A. (2020) · Advanced Theory and Simulations · doi:10.1002/adts.202000176 · Cited by 306
Metadata
- Authors
- Xu, M., Zou, X., Su, Q., Yuan, W., Cao, C., Wang, Q., Zhu, X., Feng, W., & Li, F.
- Venue
- Nature Communications
- Published
- 2018-07-12
- Volume
- 9
- Issue
- 1
- Pages
- 2698-2698
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2863943634
- Cited by
- 290
- References
- 43
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.