The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Digital acoustofluidics enables contactless and programmable liquid handling
Open accessAbstract
For decades, scientists have pursued the goal of performing automated reactions in a compact fluid processor with minimal human intervention. Most advanced fluidic handling technologies (e.g., microfluidic chips and micro-well plates) lack fluid rewritability, and the associated benefits of multi-path routing and re-programmability, due to surface-adsorption-induced contamination on contacting structures. This limits their processing speed and the complexity of reaction test matrices. We present a contactless droplet transport and processing technique called digital acoustofluidics which dynamically manipulates droplets with volumes from 1 nL to 100 µL along any planar axis via acoustic-streaming-induced hydrodynamic traps, all in a contamination-free (lower than 10−10% diffusion into the fluorinated carrier oil layer) and biocompatible (99.2% cell viability) manner. Hence, digital acoustofluidics can execute reactions on overlapping, non-contaminated, fluidic paths and can scale to perform massive interaction matrices within a single device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Droplet barcoding for single-cell transcriptomics applied to embryonic stem cells
Klein, A. M., Mazutis, L., Akartuna, I., Tallapragada, N., Veres, A., Li, V., Peshkin, L., Weitz, D. A., & Kirschner, M. W. (2015) · Cell · doi:10.1016/j.cell.2015.04.044 · Cited by 3,356
Reconstructing lineage hierarchies of the distal lung epithelium using single-cell RNA-seq
Treutlein, B., Brownfield, D. G., Wu, A. R., Neff, N. F., Mantalas, G. L., Espinoza, F. H., Desai, T. J., Krasnow, M. A., & Quake, S. R. (2014) · Nature · doi:10.1038/nature13173 · Cited by 1,342
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Self-citationCheck Hayden, E. (2014) · Nature · doi:10.1038/516131a · Cited by 72
Cited by
Acoustic tweezers for the life sciences
Ozcelik, A., Rufo, J., Guo, F., Gu, Y., Li, P., Lata, J., & Huang, T. J. (2018) · Nature Methods · doi:10.1038/s41592-018-0222-9 · Cited by 826
Self-citationAcoustofluidic separation of cells and particles
Wu, M., Ozcelik, A., Rufo, J., Wang, Z., Fang, R., & Jun Huang, T. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0064-3 · Cited by 453
The 2019 surface acoustic waves roadmap
Delsing, P., Cleland, A. N., Schuetz, M. J. A., Knörzer, J., Giedke, G., Cirac, J. I., Srinivasan, K., Wu, M., Balram, K. C., Bäuerle, C., et al. (2019) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ab1b04 · Cited by 396
Zhang, P., Bachman, H., Ozcelik, A., & Huang, T. J. (2020) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-090919-102205 · Cited by 316
Self-citationRecent Advances in Microfluidic Technology for Bioanalysis and Diagnostics
Berlanda, S. F., Breitfeld, M., Dietsche, C. L., & Dittrich, P. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04366 · Cited by 305
Metadata
- Authors
- Zhang, S. P., Lata, J., Chen, C., Mai, J., Guo, F., Tian, Z., Ren, L., Mao, Z., Huang, P.-H., Li, P., Yang, S., & Huang, T. J.
- Venue
- Nature Communications
- Published
- 2018-07-26
- Volume
- 9
- Issue
- 1
- Pages
- 2928-2928
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2884694184
- Cited by
- 207
- References
- 5
- FWCI
- 9.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Digital acoustofluidics enables contactless and programmable liquid handling. https://app.cochat.ai/papers/10.1038/s41467-018-05297-z
- The paper
- Zhang, S. P., Lata, J., Chen, C., Mai, J., Guo, F., Tian, Z., Ren, L., Mao, Z., Huang, P.-H., Li, P., Yang, S., & Huang, T. J. (2018). Digital acoustofluidics enables contactless and programmable liquid handling. Nature Communications. https://doi.org/10.1038/s41467-018-05297-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.