A fast and sensitive room-temperature graphene nanomechanical bolometer
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Bolometers are a powerful means of detecting light. Emerging applications demand that bolometers work at room temperature, while maintaining high speed and sensitivity, properties which are inherently limited by the heat capacity of the detector. To this end, graphene has generated interest, because it has the lowest mass per unit area of any material, while also possessing extreme thermal stability and an unmatched spectral absorbance. Yet, due to its weakly temperature-dependent electrical resistivity, graphene has failed to challenge the state-of-the-art at room temperature. Here, in a departure from conventional bolometry, we use a graphene nanoelectromechanical system to detect light via resonant sensing. In our approach, absorbed light heats and thermally tensions a suspended graphene resonator, thereby shifting its resonant frequency. Using the resonant frequency as a readout for photodetection, we achieve a room-temperature noise-equivalent power (2 pW Hz−1/2) and bandwidth (from 10 kHz up to 1.3 MHz), challenging the state-of-the-art.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fine Structure Constant Defines Visual Transparency of Graphene
Nair, R. R., Blake, P., Grigorenko, A. N., Novoselov, K. S., Booth, T. J., Stauber, T., Peres, N. M. R., & Geim, A. K. (2008) · Science · doi:10.1126/science.1156965 · Cited by 9,084
Photodetectors based on graphene, other two-dimensional materials and hybrid systems
Koppens, F. H. L., Mueller, T., Avouris, P., Ferrari, A. C., Vitiello, M. S., & Polini, M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.215 · Cited by 3,828
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Cited by
Silicon/2D-material photodetectors: from near-infrared to mid-infrared
Liu, C., Guo, J., Yu, L., Li, J., Zhang, M., Li, H., Shi, Y., & Dai, D. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00551-4 · Cited by 473
Shim, J., Lim, J., Kim, I., Jeong, J., Kim, B. H., Kim, S. K., Geum, D.-M., & Kim, S. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-01803-3 · Cited by 31
“Bolometers, a class of thermal-type PD, convert light-induced temperature fl uctuations into changes in electrical resistance 23 – 25 .”
Metadata
- Authors
- Blaikie, A., Miller, D., & Alemán, B. J.
- Venue
- Nature Communications
- Published
- 2019-10-17
- Volume
- 10
- Issue
- 1
- Pages
- 4726-4726
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2898857386
- Cited by
- 165
- References
- 3
- FWCI
- 7.56
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fast and sensitive room-temperature graphene nanomechanical bolometer. https://app.cochat.ai/papers/10.1038/s41467-019-12562-2
- The paper
- Blaikie, A., Miller, D., & Alemán, B. J. (2019). A fast and sensitive room-temperature graphene nanomechanical bolometer. Nature Communications. https://doi.org/10.1038/s41467-019-12562-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.