CoChat

Quantum effect-based flexible and transparent pressure sensors with ultrahigh sensitivity and sensing density

Open access
Shi, Lan, Li, Zhuo, Chen, Min, Qin, Yajie, Jiang, Yizhou, Wu, Limin · 2020 · Nature Communications

The DOI matches its Crossref record; 36 of the 37 references it cites were found in a registry or an index.

Abstract

Although high-performance flexible pressure sensors have been extensively investigated in recent years owing to their diverse applications in biomedical and information technologies, fabricating ultrasensitive sensors with high pixel density based on current transduction mechanisms still remains great challenging. Herein, we demonstrate a design idea based on Fowler-Nordheim tunnelling effect for fabrication of pressure sensors with ultrahigh sensitivity and sensing density by spin-coating extremely low urchin-like hollow carbon spheres (less than 1.5 wt.%) dispersed in polydimethylsiloxane, which is distinct from the current transduction mechanisms. This sensor exhibits an ultrahigh sensitivity of 260.3 kPa−1 at 1 Pa, a proof-of-concept demonstration of a high sensing density of 400 cm−2, high transparency and temperature noninterference. In addition, it can be fabricated by an industrially viable and scalable spin-coating method, providing an efficient avenue for realizing large-scale production and application of ultrahigh sensitivity flexible pressure sensors on various surfaces and in in vivo environments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-17298-y

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Fabrication and characterization of the thin-film sensor. a Typical scanning transmission electron microscopy (STEM) images showing the UHCSs and the thickness of the shell. Scale bar: 250 nm. b Typical transmission electron microscopy (TEM) images showing the spine length and the tip diameter of the sphere. Scale bars: 200 and 60 nm. c Photo of the peeled-off thin film in a petri dish. Scale bar: 15 mm. d Light transmittance from 400 to 1500 nm. e Optical photography of the urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS) pressure sensor on a fingertip and three-dimensional scheme of the tiny sensor. Scale bars: 10 mm and 3 μm.
Fig. 1 Fabrication and characterization of the thin-film sensor. a Typical scanning transmission electron microscopy (STEM) images showing the UHCSs and the thickness of the shell. Scale bar: 250 nm. b Typical transmission electron microscopy (TEM) images showing the spine length and the tip diameter of the sphere. Scale bars: 200 and 60 nm. c Photo of the peeled-off thin film in a petri dish. Scale bar: 15 mm. d Light transmittance from 400 to 1500 nm. e Optical photography of the urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS) pressure sensor on a fingertip and three-dimensional scheme of the tiny sensor. Scale bars: 10 mm and 3 μm.CC BY · PubMed Central
Fig. 2 Elastic and resistance behavior of the thin-film sensor. a Current–voltage characteristic of an unloaded and loaded (80 Pa) sample of the urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS), respectively. The error bars represent one standard deviation. b Resistance response and pressure sensitivity of the pressure sensor after normalization. c Instant response of the pressure sensor, which exhibits a response time of 60 ms for loading and 30 ms for unloading. The inserts are the magnified curves. d Resistance of the sensor at a pressure between 20 and 200 Pa in the 5000 cycles fatigue test. e Resistance changes under a tuned loading force of different amplitudes at 4 Hz with two 6.25 cm2 ITO electrodes. f Response of the sensor to different applied pressures from 25 to 160 °C.
Fig. 2 Elastic and resistance behavior of the thin-film sensor. a Current–voltage characteristic of an unloaded and loaded (80 Pa) sample of the urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS), respectively. The error bars represent one standard deviation. b Resistance response and pressure sensitivity of the pressure sensor after normalization. c Instant response of the pressure sensor, which exhibits a response time of 60 ms for loading and 30 ms for unloading. The inserts are the magnified curves. d Resistance of the sensor at a pressure between 20 and 200 Pa in the 5000 cycles fatigue test. e Resistance changes under a tuned loading force of different amplitudes at 4 Hz with two 6.25 cm2 ITO electrodes. f Response of the sensor to different applied pressures from 25 to 160 °C.CC BY · PubMed Central
Fig. 3 Effect of immersion on the thin-film sensor. a Self-unfolding in water for 9 s, scale bar: 20 mm. b Device for testing the resistance response in PBS solution, scale bar: 10 mm. c Resistance response and pressure sensitivity of the pressure sensor in PBS solution. d Resistance of the sensor over 4000 loading cycles in PBS solution.
Fig. 3 Effect of immersion on the thin-film sensor. a Self-unfolding in water for 9 s, scale bar: 20 mm. b Device for testing the resistance response in PBS solution, scale bar: 10 mm. c Resistance response and pressure sensitivity of the pressure sensor in PBS solution. d Resistance of the sensor over 4000 loading cycles in PBS solution.CC BY · PubMed Central
Fig. 4 Theoretical calculation of the relationship curves of the thin-film sensor. a Sketch of urchin-like hollow carbon sphere, polydimethylsiloxane, urchin-like hollow carbon sphere (UHCS-PDMS-UHCS) units when pressure is exerted. b Three-dimensional diagram of the current density versus the concentration and diameter of the urchin-like hollow carbon sphere (UHCS). c Relationship between the current density and the fraction of UHCS. d Results of the electrical conductivity test with different concentrations of urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS) and a fitting curve of the percolation effect. The error bars represent one standard deviation.
Fig. 4 Theoretical calculation of the relationship curves of the thin-film sensor. a Sketch of urchin-like hollow carbon sphere, polydimethylsiloxane, urchin-like hollow carbon sphere (UHCS-PDMS-UHCS) units when pressure is exerted. b Three-dimensional diagram of the current density versus the concentration and diameter of the urchin-like hollow carbon sphere (UHCS). c Relationship between the current density and the fraction of UHCS. d Results of the electrical conductivity test with different concentrations of urchin-like hollow carbon sphere polydimethylsiloxane film (UHCS-PDMS) and a fitting curve of the percolation effect. The error bars represent one standard deviation.CC BY · PubMed Central
Fig. 5 Fabrication design and performance of the sensor array. a Relationship between the minimum detection area and the urchin-like hollow carbon sphere (UHCS) concentration. b Sketch of the crosstalk verification test. c Photographs of a 5-μm-wide electrode used to form a 25 μm2 area pressure sensor. The scale bars are 2 mm, 100 μm and 10 μm. d Schematic diagram of the 25 μm2 sensor with crossed electrodes. e Three types (sine, rectangular, and triangular) of cyclic pressure applied in a real-time sensing test of the 25 μm2 pressure sensor shown in d. The black curve shows the loading force change with time, and the red curve shows the resistance change. f Photographs of two 5-μm-wide electrodes used for the crosstalk verification test. The scale bars are 2 mm, 100 μm, and 10 μm. g Three types (sine, rectangular, and triangular) of cyclic pressure applied in a real-time sensing test of the verification test sensor shown in f. h Detection by a 64 × 64 pixel pressure sensor of two tiny balls of 0.02 and 0.1 g. Scale bars, 6.5 mm in the sensor photograph and 300 μm in the magnified optical micrograp.
Fig. 5 Fabrication design and performance of the sensor array. a Relationship between the minimum detection area and the urchin-like hollow carbon sphere (UHCS) concentration. b Sketch of the crosstalk verification test. c Photographs of a 5-μm-wide electrode used to form a 25 μm2 area pressure sensor. The scale bars are 2 mm, 100 μm and 10 μm. d Schematic diagram of the 25 μm2 sensor with crossed electrodes. e Three types (sine, rectangular, and triangular) of cyclic pressure applied in a real-time sensing test of the 25 μm2 pressure sensor shown in d. The black curve shows the loading force change with time, and the red curve shows the resistance change. f Photographs of two 5-μm-wide electrodes used for the crosstalk verification test. The scale bars are 2 mm, 100 μm, and 10 μm. g Three types (sine, rectangular, and triangular) of cyclic pressure applied in a real-time sensing test of the verification test sensor shown in f. h Detection by a 64 × 64 pixel pressure sensor of two tiny balls of 0.02 and 0.1 g. Scale bars, 6.5 mm in the sensor photograph and 300 μm in the magnified optical micrograp.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Research works printed but not linked: 1

  1. XU, J. & LI, K. The research on resistance of electrical contact. Electr. Eng. Mater. 1, 10–13 (2011).

Cited by

See all 180

Metadata

Authors
Shi, L., Li, Z., Chen, M., Qin, Y., Jiang, Y., & Wu, L.
Affiliations
Fudan University (CN)
Corresponding author
Wu, Limin
Venue
Nature Communications
Published
2020-07-15
Volume
11
Issue
1
Pages
3529-3529
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3042916504
Cited by
180
References
37
Citations by year
2026: 24 · 2025: 38 · 2024: 35 · 2023: 30 · 2022: 33 · 2021: 18 · 2020: 2
FWCI
6.52
Type
journal article
Language
en
Open access
Licence
Locations
  • Nature Communications (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Science Foundation of China | National Natural Science Foundation of China-Yunnan Joint Fund (51721002)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
Keywords
flexible pressure sensors, polydimethylsiloxane, spin coating, ultrahigh sensitivity, high pixel density, in vivo sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantum effect-based flexible and transparent pressure sensors with ultrahigh sensitivity and sensing density. https://app.cochat.ai/papers/10.1038/s41467-020-17298-y
The paper
Shi, L., Li, Z., Chen, M., Qin, Y., Jiang, Y., & Wu, L. (2020). Quantum effect-based flexible and transparent pressure sensors with ultrahigh sensitivity and sensing density. Nature Communications. https://doi.org/10.1038/s41467-020-17298-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.