The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
A high performance wearable strain sensor with advanced thermal management for motion monitoring
Open accessAbstract
Resistance change under mechanical stimuli arouses mass operational heat, damaging the performance, lifetime, and reliability of stretchable electronic devices, therefore rapid thermal heat dissipating is necessary. Here we report a stretchable strain sensor with outstanding thermal management. Besides a high stretchability and sensitivity testified by human motion monitoring, as well as long-term durability, an enhanced thermal conductivity from the casted thermoplastic polyurethane-boron nitride nanosheets layer helps rapid heat transmission to the environments, while the porous electrospun fibrous thermoplastic polyurethane membrane leads to thermal insulation. A 32% drop of the real time saturated temperature is achieved. For the first time we in-situ investigated the dynamic operational temperature fluctuation of stretchable electronics under repeating stretching-releasing processes. Finally, cytotoxicity test confirms that the nanofillers are tightly restricted in the nanocomposites, making it harmless to human health. All the results prove it an excellent candidate for the next-generation of wearable devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Unusually High Thermal Conductivity of Carbon Nanotubes
Berber, S., Kwon, Y.-K., & Tománek, D. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.4613 · Cited by 3,087
Atomic layers of hybridized boron nitride and graphene domains
Ci, L., Song, L., Jin, C., Jariwala, D., Wu, D., Li, Y., Srivastava, A., Wang, Z. F., Storr, K., Balicas, L., et al. (2010) · Nature Materials · doi:10.1038/nmat2711 · Cited by 2,166
Self-citationThermal conductivity of polymer-based composites: Fundamentals and applications
Chen, H., Ginzburg, V. V., Yang, J., Yang, Y., Liu, W., Huang, Y., Du, L., & Chen, B. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.03.001 · Cited by 2,049
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Zhi, C., Bando, Y., Tang, C., Kuwahara, H., & Golberg, D. (2009) · Advanced Materials · doi:10.1002/adma.200900323 · Cited by 1,756
Review of thermal conductivity in composites: Mechanisms, parameters and theory
Burger, N., Laachachi, A., Ferriol, M., Lutz, M., Toniazzo, V., & Ruch, D. (2016) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2016.05.001 · Cited by 1,357
Functionalized hexagonal boron nitride nanomaterials: emerging properties and applications
Weng, Q., Wang, X., Wang, X., Bando, Y., & Golberg, D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00869g · Cited by 1,282
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
High‐Stretchability, Ultralow‐Hysteresis ConductingPolymer Hydrogel Strain Sensors for Soft Machines
Shen, Z., Zhang, Z., Zhang, N., Li, J., Zhou, P., Hu, F., Rong, Y., Lu, B., & Gu, G. (2022) · Advanced Materials · doi:10.1002/adma.202203650 · Cited by 574
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Flexible all-textile dual tactile-tension sensors for monitoring athletic motion during taekwondo
Ma, Y., Ouyang, J., Raza, T., Li, P., Jian, A., Li, Z., Liu, H., Chen, M., Zhang, X., Qu, L., et al. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.105941 · Cited by 145
Metadata
- Authors
- Tan, C., Dong, Z., Li, Y., Zhao, H., Huang, X., Zhou, Z., Jiang, J.-W., Long, Y.-Z., Jiang, P., Zhang, T.-Y., & Sun, B.
- Venue
- Nature Communications
- Published
- 2020-07-15
- Volume
- 11
- Issue
- 1
- Pages
- 3530-3530
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3043667050
- Cited by
- 580
- References
- 60
- FWCI
- 22.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A high performance wearable strain sensor with advanced thermal management for motion monitoring. https://app.cochat.ai/papers/10.1038/s41467-020-17301-6
- The paper
- Tan, C., Dong, Z., Li, Y., Zhao, H., Huang, X., Zhou, Z., Jiang, J.-W., Long, Y.-Z., Jiang, P., Zhang, T.-Y., & Sun, B. (2020). A high performance wearable strain sensor with advanced thermal management for motion monitoring. Nature Communications. https://doi.org/10.1038/s41467-020-17301-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.