Multiscale real time and high sensitivity ion detection with complementary organic electrochemical transistors amplifier
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Ions are ubiquitous biological regulators playing a key role for vital processes in animals and plants. The combined detection of ion concentration and real-time monitoring of small variations with respect to the resting conditions is a multiscale functionality providing important information on health states. This multiscale functionality is still an open challenge for current ion sensing approaches. Here we show multiscale real-time and high-sensitivity ion detection with complementary organic electrochemical transistors amplifiers. The ion-sensing amplifier integrates in the same device both selective ion-to-electron transduction and local signal amplification demonstrating a sensitivity larger than 2300 mV V−1 dec−1, which overcomes the fundamental limit. It provides both ion detection over a range of five orders of magnitude and real-time monitoring of variations two orders of magnitude lower than the detected concentration, viz. multiscale ion detection. The approach is generally applicable to several transistor technologies and opens opportunities for multifunctional enhanced bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Ultralow-power organic complementary circuits
Klauk, H., Zschieschang, U., Pflaum, J., & Halik, M. (2007) · Nature · doi:10.1038/nature05533 · Cited by 1,398
Clinical Methods: The History, Physical, and Laboratory Examinations
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-7-563_2 · Cited by 1,396
He, F. J., & MacGregor, G. A. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2008.144 · Cited by 1,123
Steady‐State and Transient Behavior of Organic Electrochemical Transistors
Bernards, D. A., & Malliaras, G. G. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601239 · Cited by 997
High transconductance organic electrochemical transistors
Khodagholy, D., Rivnay, J., Sessolo, M., Gurfinkel, M., Leleux, P., Jimison, L. H., Stavrinidou, E., Herve, T., Sanaur, S., Owens, R. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms3133 · Cited by 862
High-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 728
Self-citationThe Rise of Organic Bioelectronics
Rivnay, J., Owens, R. M., & Malliaras, G. G. (2014) · Chemistry of Materials · doi:10.1021/cm4022003 · Cited by 713
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Neuromorphic device architectures with global connectivity through electrolyte gating.
Gkoupidenis, P., Koutsouras, D. A., & Malliaras, G. G. (2017) · Nature Communications · doi:10.1038/ncomms15448 · Cited by 353
Self-citation
Cited by
Vertical organic electrochemical transistors for complementary circuits
Huang, W., Chen, J., Yao, Y., Zheng, D., Ji, X., Feng, L.-W., Moore, D., Glavin, N. R., Xie, M., Chen, Y., et al. (2023) · Nature · doi:10.1038/s41586-022-05592-2 · Cited by 423
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Self-citationA guide for the characterization of organic electrochemical transistors and channel materials
Ohayon, D., Druet, V., & Inal, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00920j · Cited by 350
Organic electrochemical neurons and synapses with ion mediated spiking
Harikesh, P. C., Yang, C.-Y., Tu, D., Gerasimov, J. Y., Dar, A. M., Armada-Moreira, A., Massetti, M., Kroon, R., Bliman, D., Olsson, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28483-6 · Cited by 306
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
An organic artificial spiking neuron for in situ neuromorphic sensing and biointerfacing
Sarkar, T., Lieberth, K., Pavlou, A., Frank, T., Mailaender, V., McCulloch, I., Blom, P. W. M., Torricelli, F., & Gkoupidenis, P. (2022) · Nature Electronics · doi:10.1038/s41928-022-00859-y · Cited by 238
Self-citationLiu, H., Yang, A., Song, J., Wang, N., Lam, P., Li, Y., Law, H. K.-W., & Yan, F. (2021) · Science Advances · doi:10.1126/sciadv.abg8387 · Cited by 233
Organic Electrochemical Transistors: An Emerging Technology for Biosensing
Marks, A., Griggs, S., Gasparini, N., & Moser, M. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202102039 · Cited by 213
Wu, H., Yang, C., Li, Q., Kolhe, N. B., Strakosas, X., Stoeckel, M., Wu, Z., Jin, W., Savvakis, M., Kroon, R., et al. (2022) · Advanced Materials · doi:10.1002/adma.202106235 · Cited by 205
Metadata
- Authors
- Romele, P., Gkoupidenis, P., Koutsouras, D. A., Lieberth, K., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F.
- Venue
- Nature Communications
- Published
- 2020-07-27
- Volume
- 11
- Issue
- 1
- Pages
- 3743-3743
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3045419555
- Cited by
- 170
- References
- 53
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.