Multiscale real time and high sensitivity ion detection with complementary organic electrochemical transistors amplifier
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Ions are ubiquitous biological regulators playing a key role for vital processes in animals and plants. The combined detection of ion concentration and real-time monitoring of small variations with respect to the resting conditions is a multiscale functionality providing important information on health states. This multiscale functionality is still an open challenge for current ion sensing approaches. Here we show multiscale real-time and high-sensitivity ion detection with complementary organic electrochemical transistors amplifiers. The ion-sensing amplifier integrates in the same device both selective ion-to-electron transduction and local signal amplification demonstrating a sensitivity larger than 2300 mV V−1 dec−1, which overcomes the fundamental limit. It provides both ion detection over a range of five orders of magnitude and real-time monitoring of variations two orders of magnitude lower than the detected concentration, viz. multiscale ion detection. The approach is generally applicable to several transistor technologies and opens opportunities for multifunctional enhanced bioelectronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Ultralow-power organic complementary circuits
Klauk, H., Zschieschang, U., Pflaum, J., & Halik, M. (2007) · Nature · doi:10.1038/nature05533 · Cited by 1,398
Clinical Methods: The History, Physical, and Laboratory Examinations
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-7-563_2 · Cited by 1,396
He, F. J., & MacGregor, G. A. (2009) · Journal of Human Hypertension · doi:10.1038/jhh.2008.144 · Cited by 1,123
Steady‐State and Transient Behavior of Organic Electrochemical Transistors
Bernards, D. A., & Malliaras, G. G. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601239 · Cited by 997
High transconductance organic electrochemical transistors
Khodagholy, D., Rivnay, J., Sessolo, M., Gurfinkel, M., Leleux, P., Jimison, L. H., Stavrinidou, E., Herve, T., Sanaur, S., Owens, R. M., et al. (2013) · Nature Communications · doi:10.1038/ncomms3133 · Cited by 862
High-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 728
Self-citationThe Rise of Organic Bioelectronics
Rivnay, J., Owens, R. M., & Malliaras, G. G. (2014) · Chemistry of Materials · doi:10.1021/cm4022003 · Cited by 713
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Neuromorphic device architectures with global connectivity through electrolyte gating.
Gkoupidenis, P., Koutsouras, D. A., & Malliaras, G. G. (2017) · Nature Communications · doi:10.1038/ncomms15448 · Cited by 353
Self-citationComplementary Logic Circuits Based on High‐Performance n‐Type Organic Electrochemical Transistors
Sun, H., Vagin, M., Wang, S., Crispin, X., Forchheimer, R., Berggren, M., & Fabiano, S. (2018) · Advanced Materials · doi:10.1002/adma.201704916 · Cited by 353
Lin, P., Luo, X., Hsing, I., & Yan, F. (2011) · Advanced Materials · doi:10.1002/adma.201102017 · Cited by 346
Active Materials for Organic Electrochemical Transistors
Zeglio, E., & Inganäs, O. (2018) · Advanced Materials · doi:10.1002/adma.201800941 · Cited by 333
Ion-Sensitive Properties of Organic Electrochemical Transistors
Lin, P., Yan, F., & Chan, H. L. W. (2010) · ACS Applied Materials & Interfaces · doi:10.1021/am100154e · Cited by 294
Direct metabolite detection with an n-type accumulation mode organic electrochemical transistor
Pappa, A. M., Ohayon, D., Giovannitti, A., Maria, I. P., Savva, A., Uguz, I., Rivnay, J., McCulloch, I., Owens, R. M., & Inal, S. (2018) · Science Advances · doi:10.1126/sciadv.aat0911 · Cited by 269
Single-molecule detection with a millimetre-sized transistor
Macchia, E., Manoli, K., Holzer, B., Di Franco, C., Ghittorelli, M., Torricelli, F., Alberga, D., Mangiatordi, G. F., Palazzo, G., Scamarcio, G., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05235-z · Cited by 253
Self-citationPappa, A., Curto, V. F., Braendlein, M., Strakosas, X., Donahue, M. J., Fiocchi, M., Malliaras, G. G., & Owens, R. M. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600494 · Cited by 218
Raimondo, J. V., Burman, R. J., Katz, A. A., & Akerman, C. J. (2015) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00419 · Cited by 213
Ion‐Selective Organic Electrochemical Transistors
Sessolo, M., Rivnay, J., Bandiello, E., Malliaras, G. G., & Bolink, H. J. (2014) · Advanced Materials · doi:10.1002/adma.201400731 · Cited by 206
Ion channels: Function unravelled by dysfunction
Jentsch, T. J., Hübner, C. A., & Fuhrmann, J. C. (2004) · Nature Cell Biology · doi:10.1038/ncb1104-1039 · Cited by 201
Roles and Transport of Sodium and Potassium in Plants
Nieves‐Cordones, M., Al-Burki, F. R., & Sentenac, H. (2016) · Metal ions in life sciences · doi:10.1007/978-3-319-21756-7_9 · Cited by 199 · cited 1×
“(2) and A can be calculated by differentiating the OECT current equation (see Supplementary Eq.”
Wu, X., Surendran, A., Ko, J., Filonik, O., Herzig, E. M., Müller‐Buschbaum, P., & Leong, W. L. (2018) · Advanced Materials · doi:10.1002/adma.201805544 · Cited by 167
Ghittorelli, M., Lingstedt, L., Romele, P., Crăciun, N. I., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F. (2018) · Nature Communications · doi:10.1038/s41467-018-03932-3 · Cited by 163
Self-citationPicca, R. A., Manoli, K., Macchia, E., Sarcina, L., Franco, C. D., Cioffi, N., Blasi, D., Österbacka, R., Torricelli, F., Scamarcio, G., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201904513 · Cited by 162
Self-citationVoltage Amplifier Based on Organic Electrochemical Transistor
Braendlein, M., Lonjaret, T., Leleux, P., Badier, J., & Malliaras, G. G. (2016) · Advanced Science · doi:10.1002/advs.201600247 · Cited by 161
Romele, P., Ghittorelli, M., Kovacs-Vajna, Z. M., & Torricelli, F. (2019) · Nature Communications · doi:10.1038/s41467-019-11073-4 · Cited by 145
Self-citationMacchia, E., Romele, P., Manoli, K., Ghittorelli, M., Magliulo, M., Kovacs-Vajna, Z. M., Torricelli, F., & Torsi, L. (2018) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aad0cb · Cited by 141
Self-citationElectrolyte‐Gated Organic Field‐Effect Transistor for Selective Reversible Ion Detection
Schmoltner, K., Kofler, J., Klug, A., & List, E. J. W. (2013) · Advanced Materials · doi:10.1002/adma.201303281 · Cited by 137
Human stress monitoring through an organic cotton-fiber biosensor
Coppedé, N., Tarabella, G., Villani, M., Calestani, D., Iannotta, S., & Zappettini, A. (2014) · Journal of Materials Chemistry B · doi:10.1039/c4tb00317a · Cited by 136
Membrane‐Free Detection of Metal Cations with an Organic Electrochemical Transistor
Wustoni, S., Combe, C. M. S., Ohayon, D., Akhtar, M. H., McCulloch, I. A., & Inal, S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201904403 · Cited by 135
Li, Y., Yang, C., & Guo, X. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00347 · Cited by 133
Subthreshold Operation of Organic Electrochemical Transistors for Biosignal Amplification
Venkatraman, V., Friedlein, J. T., Giovannitti, A., Maria, I. P., McCulloch, I. A., McLeod, R. R., & Rivnay, J. (2018) · Advanced Science · doi:10.1002/advs.201800453 · Cited by 128
About the amplification factors in organic bioelectronic sensors
Macchia, E., Picca, R. A., Manoli, K., Franco, C. D., Blasi, D., Sarcina, L., Ditaranto, N., Cioffi, N., Österbacka, R., Scamarcio, G., et al. (2020) · Materials Horizons · doi:10.1039/c9mh01544b · Cited by 125
Self-citationMacchia, E., Manoli, K., Holzer, B., Franco, C. D., Picca, R. A., Cioffi, N., Scamarcio, G., Palazzo, G., & Torsi, L. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01778-2 · Cited by 111
Hong, K., Kim, Y. H., Kim, S. H., Xie, W. L., Xu, W. D., Kim, C. H., & Frisbie, C. D. (2014) · Advanced Materials · doi:10.1002/adma.201401330 · Cited by 109
Hai, W., Goda, T., Takeuchi, H., Yamaoka, S., Horiguchi, Y., Matsumoto, A., & Miyahara, Y. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.081 · Cited by 105
Macchia, E., Tiwari, A., Manoli, K., Holzer, B., Ditaranto, N., Picca, R. A., Cioffi, N., Franco, C. D., Scamarcio, G., Palazzo, G., et al. (2019) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b04414 · Cited by 94
EGOFET Peptide Aptasensor for Label‐Free Detection of Inflammatory Cytokines in Complex Fluids
Berto, M., Diacci, C., D’Agata, R., Pinti, M., Bianchini, E., Lauro, M. D., Casalini, S., Cossarizza, A., Berggren, M., Simon, D. T., et al. (2017) · Advanced Biosystems · doi:10.1002/adbi.201700072 · Cited by 93
Label free detection of plant viruses with organic transistor biosensors
Berto, M., Vecchi, E., Baiamonte, L., Condò, C., Sensi, M., Lauro, M. D., Sola, M., Stradis, A. D., Biscarini, F., Minafra, A., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.080 · Cited by 91
Zhang, J., Rupakula, M., Bellando, F., Garcia-Cordero, E., Longo, J., Wildhaber, F., Herment, G., Guérin, H., & Ionescu, A. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00597 · Cited by 87
Graphene field effect transistors for highly sensitive and selective detection of K+ ions
Li, H., Zhu, Y., Islam, M. S., Rahman, M. A., Walsh, K. B., & Koley, G. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.129 · Cited by 87
Understanding Spreading Depression from Headache to Sudden Unexpected Death
Cozzolino, O., Marchese, M., Trovato, F., Pracucci, E., Ratto, G. M., Buzzi, M. G., Sicca, F., & Santorelli, F. M. (2018) · Frontiers in Neurology · doi:10.3389/fneur.2018.00019 · Cited by 86
Kumar, N. C., Kumar, J., & Panda, S. (2016) · IEEE Electron Device Letters · doi:10.1109/led.2016.2536359 · Cited by 81
Ultra-high gain diffusion-driven organic transistor
Torricelli, F., Colalongo, L., Raiteri, D., Kovacs-Vajna, Z. M., & Cantatore, E. (2016) · Nature Communications · doi:10.1038/ncomms10550 · Cited by 65
Self-citationPorrazzo, R., Luzio, A., Bellani, S., Bonacchini, G. E., Noh, Y., Kim, Y., Lanzani, G., Antognazza, M. R., & Caironi, M. (2017) · ACS Omega · doi:10.1021/acsomega.6b00256 · Cited by 50
Ambipolar Organic Tri‐Gate Transistor for Low‐Power Complementary Electronics
Torricelli, F., Ghittorelli, M., Smits, E. C. P., Roelofs, C. W. S., Janssen, R. A. J., Gelinck, G. H., Kovacs-Vajna, Z. M., & Cantatore, E. (2015) · Advanced Materials · doi:10.1002/adma.201503414 · Cited by 45
Self-citationToward a highly selective artificial saliva sensor using printed hybrid field effect transistors
Bao, C., Kaur, M., & Kim, W. S. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.01.062 · Cited by 44
Nanoscale Ion-Doped Polymer Transistors
Thiburce, Q., Giovannitti, A., McCulloch, I. A., & Campbell, A. J. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04717 · Cited by 40
Plant growth response to salt stress
Maas, E. V. (1993) · Tasks for vegetation science · doi:10.1007/978-94-011-1858-3_31 · Cited by 36
Zinc oxide ion-sensitive field-effect transistors and biosensors
Yano, M., Koike, K., Mukai, K., Onaka, T., Hirofuji, Y., Ogata, K.-I., Omatu, S., Maemoto, T., & Sasa, S. (2014) · physica status solidi (a) · doi:10.1002/pssa.201300589 · Cited by 35
Kabaa, E. A., Abdulateef, S. A., Ahmed, N. M., Hassan, Z., & Sabah, F. A. (2019) · Applied Physics A · doi:10.1007/s00339-019-3056-0 · Cited by 34
Monitoring of Cell Layer Integrity with a Current‐Driven Organic Electrochemical Transistor
Lingstedt, L. V., Ghittorelli, M., Brückner, M., Reinholz, J., Crăciun, N. I., Torricelli, F., Mailänder, V., Gkoupidenis, P., & Blom, P. W. M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900128 · Cited by 29
Self-citationWu, Y., Xiao, Y., Wang, X., Li, X., & Wang, Y. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00270 · Cited by 22
Cited by
Vertical organic electrochemical transistors for complementary circuits
Huang, W., Chen, J., Yao, Y., Zheng, D., Ji, X., Feng, L.-W., Moore, D., Glavin, N. R., Xie, M., Chen, Y., et al. (2023) · Nature · doi:10.1038/s41586-022-05592-2 · Cited by 423
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Self-citationA guide for the characterization of organic electrochemical transistors and channel materials
Ohayon, D., Druet, V., & Inal, S. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00920j · Cited by 350
Organic electrochemical neurons and synapses with ion mediated spiking
Harikesh, P. C., Yang, C.-Y., Tu, D., Gerasimov, J. Y., Dar, A. M., Armada-Moreira, A., Massetti, M., Kroon, R., Bliman, D., Olsson, R., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28483-6 · Cited by 306
Liang, Y., Offenhäusser, A., Ingebrandt, S., & Mayer, D. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100061 · Cited by 239
Metadata
- Authors
- Romele, P., Gkoupidenis, P., Koutsouras, D. A., Lieberth, K., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F.
- Venue
- Nature Communications
- Published
- 2020-07-27
- Volume
- 11
- Issue
- 1
- Pages
- 3743-3743
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3045419555
- Cited by
- 170
- References
- 53
- FWCI
- 10.98
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.