Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 423

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Vertical organic electrochemical transistors for complementary circuits

Open access
Huang, Wei, Chen, Jianhua, Yao, Yao, Zheng, Ding, Ji, Xudong, Feng, Liang-Wen, Moore, David, Glavin, Nicholas R., Xie, Miao, Chen, Yao, Pankow, Robert M., Surendran, Abhijith, Wang, Zhi, Xia, Yu, Bai, Libing, Rivnay, Jonathan, Ping, Jianfeng, Guo, Xugang, Cheng, Yuhua, Marks, Tobin J., Facchetti, Antonio·2023·Nature

Abstract

Organic electrochemical transistors (OECTs) and OECT-based circuitry offer great potential in bioelectronics, wearable electronics and artificial neuromorphic electronics because of their exceptionally low driving voltages (<1 V), low power consumption (<1 µW), high transconductances (>10 mS) and biocompatibility 1–5. However, the successful realization of critical complementary logic OECTs is currently limited by temporal and/or operational instability, slow redox processes and/or switching, incompatibility with high-density monolithic integration and inferior n-type OECT performance 6–8. Here we demonstrate p- and n-type vertical OECTs with balanced and ultra-high performance by blending redox-active semiconducting polymers with a redox-inactive photocurable and/or photopatternable polymer to form an ion-permeable semiconducting channel, implemented in a simple, scalable vertical architecture that has a dense, impermeable top contact. Footprint current densities exceeding 1 kA cm−2 at less than ±0.7 V, transconductances of 0.2–0.4 S, short transient times of less than 1 ms and ultra-stable switching (>50,000 cycles) are achieved in, to our knowledge, the first vertically stacked complementary vertical OECT logic circuits. This architecture opens many possibilities for fundamental studies of organic semiconductor redox chemistry and physics in nanoscopically confined spaces, without macroscopic electrolyte contact, as well as wearable and implantable device applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-022-05592-2

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Metadata

Authors
Huang, W., Chen, J., Yao, Y., Zheng, D., Ji, X., Feng, L.-W., Moore, D., Glavin, N. R., Xie, M., Chen, Y., Pankow, R. M., Surendran, A., Wang, Z., Xia, Y., Bai, L., Rivnay, J., Ping, J., Guo, X., Cheng, Y., Marks, T. J., & Facchetti, A.
Venue
Nature
Published
2023-01-18
Volume
613
Issue
7944
Pages
496-502
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4317390660
Cited by
423
References
43
FWCI
31.50
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Vertical organic electrochemical transistors for complementary circuits. https://app.cochat.ai/papers/10.1038/s41586-022-05592-2
The paper
Huang, W., Chen, J., Yao, Y., Zheng, D., Ji, X., Feng, L.-W., Moore, D., Glavin, N. R., Xie, M., Chen, Y., Pankow, R. M., Surendran, A., Wang, Z., Xia, Y., Bai, L., Rivnay, J., Ping, J., Guo, X., Cheng, Y., . . . Facchetti, A. (2023). Vertical organic electrochemical transistors for complementary circuits. Nature. https://doi.org/10.1038/s41586-022-05592-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.