Ultra-conformal drawn-on-skin electronics for multifunctional motion artifact-free sensing and point-of-care treatment

Open access
Ershad, Faheem, Thukral, Anish, Yue, Jiping, Comeaux, Phillip, Lu, Yuntao, Shim, Hyunseok, Sim, Kyoseung, Kim, Nam-In, Rao, Zhoulyu, Guevara, Ross, Contreras, Luis, Pan, Fengjiao, Zhang, Yongcao, Guan, Ying-Shi, Yang, Pinyi, Wang, Xu, Wang, Peng, Wu, Xiaoyang, Yu, Cunjiang · 2020 · Nature Communications
Cited by 385

The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.

Abstract

An accurate extraction of physiological and physical signals from human skin is crucial for health monitoring, disease prevention, and treatment. Recent advances in wearable bioelectronics directly embedded to the epidermal surface are a promising solution for future epidermal sensing. However, the existing wearable bioelectronics are susceptible to motion artifacts as they lack proper adhesion and conformal interfacing with the skin during motion. Here, we present ultra-conformal, customizable, and deformable drawn-on-skin electronics, which is robust to motion due to strong adhesion and ultra-conformality of the electronic inks drawn directly on skin. Electronic inks, including conductors, semiconductors, and dielectrics, are drawn on-demand in a freeform manner to develop devices, such as transistors, strain sensors, temperature sensors, heaters, skin hydration sensors, and electrophysiological sensors. Electrophysiological signal monitoring during motion shows drawn-on-skin electronics’ immunity to motion artifacts. Additionally, electrical stimulation based on drawn-on-skin electronics demonstrates accelerated healing of skin wounds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-020-17619-1

Cites

53 of 53 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 DoS electronics platform featuring conductive and semiconducting inks. a DoS electronics drawing process beginning with (i) a tape-based stencil attachment to the skin (scale bar 1 cm), (ii) drawing the device with the stencil, modified ballpoint pen, and inks (scale bar 5 mm), inset is a closeup of the tip (scale bar 1 mm), (iii) removal of the stencil (scale bar 2 cm), and (iv) the completed device after drying (scale bar 1 cm). b An example DoS integrated system including a resistor, transistors, heater, EP (electrophysiological) sensors, temperature sensor, strain sensor, and skin hydration sensor drawn on human skin (scale bar 5 mm). The corresponding stencil for the conductor is shown in the inset (scale bar 1 cm). c Achievable line spacing using stencils and the conductive Ag-PEDOT:PSS ink (scale bar 1 mm). d Non-stretched (left, scale bar 1 mm) and biaxially stretched (right, scale bar 1 cm) states of the drawn structure consisting of Ag-PEDOT:PSS conductive (left square) and P3HT-NF semiconducting (right square) inks on PDMS. e Twisting (left) and poking (right, scale bars 1 cm) deformations of the drawn structure with conductive and semiconducting inks. f SEM images of the Ag-PEDOT:PSS ink showing ultraconformal contact with the grooves and bumps (left, scale bar 250 µm) on top of skin replica and cross-section showing Ag-PEDOT:PSS microstructure (right, scale bar 20 µm). The purple color indicates the skin replica. g Histology image of the Ag-PEDOT:PSS ink on skin of mice after 48 h (scale bar 100 µm). h Histology image of the P3HT-NF ink on skin of mice after 48 h (scale bar 100 µm). i Sheet resistance vs. strain while stretching the Ag-PEDOT:PSS ink up to 30% and releasing. The error bars represent the s.d. j Optical microscope images of the Ag-PEDOT:PSS ink on skin replica stretched up to 30% (scale bars 100 µm). k DoS EP sensor on the wrist of subject in stretched (top) and non-stretched (bottom) states (scale bars 5 mm).
Fig. 1 DoS electronics platform featuring conductive and semiconducting inks. a DoS electronics drawing process beginning with (i) a tape-based stencil attachment to the skin (scale bar 1 cm), (ii) drawing the device with the stencil, modified ballpoint pen, and inks (scale bar 5 mm), inset is a closeup of the tip (scale bar 1 mm), (iii) removal of the stencil (scale bar 2 cm), and (iv) the completed device after drying (scale bar 1 cm). b An example DoS integrated system including a resistor, transistors, heater, EP (electrophysiological) sensors, temperature sensor, strain sensor, and skin hydration sensor drawn on human skin (scale bar 5 mm). The corresponding stencil for the conductor is shown in the inset (scale bar 1 cm). c Achievable line spacing using stencils and the conductive Ag-PEDOT:PSS ink (scale bar 1 mm). d Non-stretched (left, scale bar 1 mm) and biaxially stretched (right, scale bar 1 cm) states of the drawn structure consisting of Ag-PEDOT:PSS conductive (left square) and P3HT-NF semiconducting (right square) inks on PDMS. e Twisting (left) and poking (right, scale bars 1 cm) deformations of the drawn structure with conductive and semiconducting inks. f SEM images of the Ag-PEDOT:PSS ink showing ultraconformal contact with the grooves and bumps (left, scale bar 250 µm) on top of skin replica and cross-section showing Ag-PEDOT:PSS microstructure (right, scale bar 20 µm). The purple color indicates the skin replica. g Histology image of the Ag-PEDOT:PSS ink on skin of mice after 48 h (scale bar 100 µm). h Histology image of the P3HT-NF ink on skin of mice after 48 h (scale bar 100 µm). i Sheet resistance vs. strain while stretching the Ag-PEDOT:PSS ink up to 30% and releasing. The error bars represent the s.d. j Optical microscope images of the Ag-PEDOT:PSS ink on skin replica stretched up to 30% (scale bars 100 µm). k DoS EP sensor on the wrist of subject in stretched (top) and non-stretched (bottom) states (scale bars 5 mm).CC BY · PubMed Central
Fig. 2 DoS electronic devices and sensors on skin replica. a Schematic of the DoS transistor based on the Ag-PEDOT:PSS ink as the conductor, P3HT-NF ink as the semiconductor, and ionic gel ink as the dielectric. b DoS transistor on skin replica under no strain (top) and 30% strain (bottom, scale bars 5 mm). c SEM image of the drawn source (S) and drain (D) electrodes and the channel (scale bar 100 µm). d I-V curve of DoS transistor without applied strain. e, f Transfer curves of DoS transistor without and 30% strain along the transistor channel length direction. g Electrical resistance of the DoS strain sensor under applied mechanical strain up to 30% and the corresponding gauge factors. Inset shows a schematic of the DoS strain sensor. The error bars represent the s.d. h Relative resistance change of the DoS strain sensor under cyclic stretching and releasing at 10% and 25% strain. i Relative resistance change of the DoS temperature sensor under different temperature conditions. j Schematic of the DoS heater based on the conductive ink. k Temperature profiles under different applied voltage on the DoS heater. l Calibration curve of the DoS heater. The error bars represent the s.d.
Fig. 2 DoS electronic devices and sensors on skin replica. a Schematic of the DoS transistor based on the Ag-PEDOT:PSS ink as the conductor, P3HT-NF ink as the semiconductor, and ionic gel ink as the dielectric. b DoS transistor on skin replica under no strain (top) and 30% strain (bottom, scale bars 5 mm). c SEM image of the drawn source (S) and drain (D) electrodes and the channel (scale bar 100 µm). d I-V curve of DoS transistor without applied strain. e, f Transfer curves of DoS transistor without and 30% strain along the transistor channel length direction. g Electrical resistance of the DoS strain sensor under applied mechanical strain up to 30% and the corresponding gauge factors. Inset shows a schematic of the DoS strain sensor. The error bars represent the s.d. h Relative resistance change of the DoS strain sensor under cyclic stretching and releasing at 10% and 25% strain. i Relative resistance change of the DoS temperature sensor under different temperature conditions. j Schematic of the DoS heater based on the conductive ink. k Temperature profiles under different applied voltage on the DoS heater. l Calibration curve of the DoS heater. The error bars represent the s.d.CC BY · PubMed Central
Fig. 3 DoS electronics on skin and wireless sensing. a IR camera images of the DoS heater on skin without applied voltage (left) and with an applied voltage of 5 V (right, scale bars 1 cm). b Ag-PEDOT:PSS ink serving as the interconnection during charging of a capacitor (left) and discharging through the resistor and LED (right, scale bars 2 cm). c Voltage of the capacitor showing charging until the battery is removed and then discharging afterwards. Inset is the circuit diagram showing a battery connected to a capacitor, which is connected to a resistor and LED that are connected in series. d DoS skin hydration sensor on skin without (left) and with applied strain (right, scale bars 2 mm). e Calibration of the DoS skin hydration sensor using a commercial hydration meter. f Impedance of the DoS skin hydration sensor without and with mechanical stretch. The arrow indicates the time at which lotion was applied to the dry skin. g DoS EP sensors without (top) and with applied strain (bottom, scale bars 2 mm). h Recorded EMG signals without (top) and with applied strain (bottom). i Recorded ECG signals without (top) and with mechanical stretch (bottom). j Schematic of the wireless transmission circuit components mounted on the arm and interface with the DoS EP sensors (scale bar 2 cm). k Average beats/min over all trials derived from the ECG signals attained with the DoS EP sensors. In the time prior to the red dashed line, the subject was standing still. After the red dashed line, the subject began walking.
Fig. 3 DoS electronics on skin and wireless sensing. a IR camera images of the DoS heater on skin without applied voltage (left) and with an applied voltage of 5 V (right, scale bars 1 cm). b Ag-PEDOT:PSS ink serving as the interconnection during charging of a capacitor (left) and discharging through the resistor and LED (right, scale bars 2 cm). c Voltage of the capacitor showing charging until the battery is removed and then discharging afterwards. Inset is the circuit diagram showing a battery connected to a capacitor, which is connected to a resistor and LED that are connected in series. d DoS skin hydration sensor on skin without (left) and with applied strain (right, scale bars 2 mm). e Calibration of the DoS skin hydration sensor using a commercial hydration meter. f Impedance of the DoS skin hydration sensor without and with mechanical stretch. The arrow indicates the time at which lotion was applied to the dry skin. g DoS EP sensors without (top) and with applied strain (bottom, scale bars 2 mm). h Recorded EMG signals without (top) and with applied strain (bottom). i Recorded ECG signals without (top) and with mechanical stretch (bottom). j Schematic of the wireless transmission circuit components mounted on the arm and interface with the DoS EP sensors (scale bar 2 cm). k Average beats/min over all trials derived from the ECG signals attained with the DoS EP sensors. In the time prior to the red dashed line, the subject was standing still. After the red dashed line, the subject began walking.CC BY · PubMed Central
Fig. 4 Comparison of DoS electronics and existing technologies for ECG sensing before and during sweat conditions. a DoS EP sensor (left, scale bar 2 mm) with ECG signals recorded before sweating (middle) and while sweating (right). b Gel electrode (left, scale bar 1 cm) with ECG signals recorded before sweating (middle) and while sweating (right). c Mesh electrode (left, scale bar 5 mm) with ECG signals recorded before sweating (middle) and while sweating (right).
Fig. 4 Comparison of DoS electronics and existing technologies for ECG sensing before and during sweat conditions. a DoS EP sensor (left, scale bar 2 mm) with ECG signals recorded before sweating (middle) and while sweating (right). b Gel electrode (left, scale bar 1 cm) with ECG signals recorded before sweating (middle) and while sweating (right). c Mesh electrode (left, scale bar 5 mm) with ECG signals recorded before sweating (middle) and while sweating (right).CC BY · PubMed Central
Fig. 5 Motion artifact-free sensing with DoS electronics. a Recorded ECG signals (middle) from the DoS EP sensors during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The orange bars indicate the duration of the stretching motion, the blue bars indicate the duration of the compressing motion, and the green bars indicate the duration of the releasing motion. b Recorded ECG signals (middle) from the gel electrodes during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The red arrows indicate artifacts. c Recorded ECG signals (middle) from the mesh electrodes during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The red arrows indicate artifacts. d Resting EMG signals recorded with vibration-induced motion of the arm. The pink bars indicate the duration of time in which the VM was turned on for the DoS EP sensors (top), gel electrodes (middle), and mesh (bottom) electrodes. e TF maps of the resting EMG signals with the vibration-induced motion for the DoS EP sensors (top), gel electrodes (middle), and mesh (bottom) electrodes. The pink bars and red lines indicate the duration of the vibrations.
Fig. 5 Motion artifact-free sensing with DoS electronics. a Recorded ECG signals (middle) from the DoS EP sensors during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The orange bars indicate the duration of the stretching motion, the blue bars indicate the duration of the compressing motion, and the green bars indicate the duration of the releasing motion. b Recorded ECG signals (middle) from the gel electrodes during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The red arrows indicate artifacts. c Recorded ECG signals (middle) from the mesh electrodes during local stretching/releasing cycle (left) and compressing/releasing cycle (right). The red arrows indicate artifacts. d Resting EMG signals recorded with vibration-induced motion of the arm. The pink bars indicate the duration of time in which the VM was turned on for the DoS EP sensors (top), gel electrodes (middle), and mesh (bottom) electrodes. e TF maps of the resting EMG signals with the vibration-induced motion for the DoS EP sensors (top), gel electrodes (middle), and mesh (bottom) electrodes. The pink bars and red lines indicate the duration of the vibrations.CC BY · PubMed Central
Fig. 6 Accelerated skin wound healing with DoS electronics. a Experimental setup showing DoS electrodes around a skin wound on the back of mice (N = 3). The DoS electrodes served as conductive paths for electrical stimulation (scale bar 2 cm). b Photos of the wound healing on day 1 (left), day 3 (middle) and day 5 (right). Top half of the wound was treated with electrical stimulation while the bottom half was left untreated and healed naturally (scale bar 1 cm). c Histology images of the treated (top, scale bar 100 µm) and untreated (bottom, scale bar 250 µm) halves of the wound on day 5. The black arrows indicate the width of the wound. d Scab width over time for the treated (black) and untreated (red) halves of the wound.
Fig. 6 Accelerated skin wound healing with DoS electronics. a Experimental setup showing DoS electrodes around a skin wound on the back of mice (N = 3). The DoS electrodes served as conductive paths for electrical stimulation (scale bar 2 cm). b Photos of the wound healing on day 1 (left), day 3 (middle) and day 5 (right). Top half of the wound was treated with electrical stimulation while the bottom half was left untreated and healed naturally (scale bar 1 cm). c Histology images of the treated (top, scale bar 100 µm) and untreated (bottom, scale bar 250 µm) halves of the wound on day 5. The black arrows indicate the width of the wound. d Scab width over time for the treated (black) and untreated (red) halves of the wound.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 53 references

Cited by

Items 201–300 of 385

Metadata

Authors
Ershad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N.-I., Rao, Z., Guevara, R., Contreras, L., Pan, F., Zhang, Y., Guan, Y.-S., Yang, P., Wang, X., Wang, P., Wu, X., & Yu, C.
Venue
Nature Communications
Published
2020-07-30
Volume
11
Issue
1
Pages
3823-3823
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3046860577
Cited by
355
References
53
FWCI
13.20
Type
journal article
Language
en
Open access
gold
Licence
Funders
  • United States Department of Defense | United States Navy | Office of Naval Research (N00014-18-1-2338)
  • U.S. Department of Health & Human Services | NIH | National Institute of Biomedical Imaging and Bioengineering (R21EB026175)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.