The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Massive and rapid COVID-19 testing is feasible by extraction-free SARS-CoV-2 RT-PCR
Open accessAbstract
Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), is commonly diagnosed by reverse transcription polymerase chain reaction (RT-PCR) to detect viral RNA in patient samples, but RNA extraction constitutes a major bottleneck in current testing. Methodological simplification could increase diagnostic availability and efficiency, benefitting patient care and infection control. Here, we describe methods circumventing RNA extraction in COVID-19 testing by performing RT-PCR directly on heat-inactivated or lysed samples. Our data, including benchmarking using 597 clinical patient samples and a standardised diagnostic system, demonstrate that direct RT-PCR is viable option to extraction-based tests. Using controlled amounts of active SARS-CoV-2, we confirm effectiveness of heat inactivation by plaque assay and evaluate various generic buffers as transport medium for direct RT-PCR. Significant savings in time and cost are achieved through RNA-extraction-free protocols that are directly compatible with established PCR-based testing pipelines. This could aid expansion of COVID-19 testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Building Predictive Models in R Using the caret Package
Kuhn, M. (2008) · Journal of Statistical Software · doi:10.18637/jss.v028.i05 · Cited by 8,863
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
Ferguson, N. M., Laydon, D. J., Nedjati-Gilani, G. L., Imai, N., Ainslie, K. E. C., Baguelin, M., Bhatia, S., Boonyasiri, A., Cucunubá, Z. M., Cuomo-Dannenburg, G., et al. (2020) · Spiral (Imperial College London) · doi:10.25561/77482 · Cited by 3,281
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · doi:10.1101/2020.03.15.20036673 · Cited by 1,948
Stability of SARS-CoV-2 in different environmental conditions
Chin, A. W. H., Chu, J. T. S., Perera, M. R. A., Hui, K. P. Y., Yen, H.-L., Chan, M. C. W., Peiris, M., & Poon, L. L. M. (2020) · The Lancet Microbe · doi:10.1016/s2666-5247(20)30003-3 · Cited by 1,946
Eubank, S., Eckstrand, I., Lewis, B., Venkatramanan, S., Marathe, M., & Barrett, C. L. (2020) · Bulletin of Mathematical Biology · doi:10.1007/s11538-020-00726-x · Cited by 881
Assays for laboratory confirmation of novel human coronavirus (hCoV-EMC) infections
Corman, V. M., Müller, M. A., Costabel, U., Timm, J., Binger, T., Meyer, B., Kreher, P., Lattwein, E., Eschbach-Bludau, M., Nitsche, A., et al. (2012) · Eurosurveillance · doi:10.2807/ese.17.49.20334-en · Cited by 360
Efficacy of various disinfectants against SARS coronavirus
Rabenau, H. F., Kampf, G., Cinatl, J., & Doerr, H. W. (2005) · Journal of Hospital Infection · doi:10.1016/j.jhin.2004.12.023 · Cited by 271
Fomsgaard, A. S., & Rosenstierne, M. W. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.14.2000398 · Cited by 184
Streefkerk, H. R. A., Verkooijen, R. P., Bramer, W. M., & Verbrugh, H. A. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.2.1900321 · Cited by 102
Cited by
Rapid, point-of-care antigen and molecular-based tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Adriano, A., Berhane, S., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., Beese, S., et al. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705 · Cited by 1,156
Diagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples
Dao Thi, V. L., Herbst, K., Boerner, K., Meurer, M., Kremer, L. P., Kirrmaier, D., Freistaedter, A., Papagiannidis, D., Galmozzi, C., Stanifer, M. L., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.abc7075 · Cited by 673
Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Berhane, S., Taylor, M., Adriano, A., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub2 · Cited by 591
Recent Developments on Therapeutic and Diagnostic Approaches for COVID-19
Majumder, J., & Minko, T. (2021) · The AAPS Journal · doi:10.1208/s12248-020-00532-2 · Cited by 505
Metadata
- Authors
- Smyrlaki, I., Ekman, M., Lentini, A., Rufino de Sousa, N., Papanicolaou, N., Vondracek, M., Aarum, J., Safari, H., Muradrasoli, S., Rothfuchs, A. G., Albert, J., Högberg, B., & Reinius, B.
- Venue
- Nature Communications
- Published
- 2020-09-23
- Volume
- 11
- Issue
- 1
- Pages
- 4812-4812
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3088011310
- Cited by
- 457
- References
- 12
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Massive and rapid COVID-19 testing is feasible by extraction-free SARS-CoV-2 RT-PCR. https://app.cochat.ai/papers/10.1038/s41467-020-18611-5
- The paper
- Smyrlaki, I., Ekman, M., Lentini, A., Rufino de Sousa, N., Papanicolaou, N., Vondracek, M., Aarum, J., Safari, H., Muradrasoli, S., Rothfuchs, A. G., Albert, J., Högberg, B., & Reinius, B. (2020). Massive and rapid COVID-19 testing is feasible by extraction-free SARS-CoV-2 RT-PCR. Nature Communications. https://doi.org/10.1038/s41467-020-18611-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.